REFRIGERATION DATA
Note: This data is based on store
temperature and humidity that does not
exceed 75°F and 55% R.H.
M4 M4E
Discharge Air °F 28 29
Evaporator °F 18 21
Unit Sizing °F 16 19
Btu/hr/ft** M4 M4E
Parallel 1325 1270
Conventional 1405 1350
**For all refrigeration equipment other than
Husssmann, use conventional BTU values.
DEFROST DATA
M4 M4E
Frequency (hr) 66
Defrost Water (lb/ft/day)88
(±15% based on case configuration and
product loading.
O
FFTIME M4 M4E
Temp Term °F 48°F 48°F
Failsafe Minutes 25 30
ELECTRIC OR GAS Not Recommended
Standard Defrost Thermostat
Close on rise: close 48°F – open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control
M4 M4E
CI/CO** 12/2°F 14/4°F
Indoor Unit Only, Pressure Defrost
Termination** 48°F
**Use a Temperature Pressure Chart to
determine PSIG conversions.
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/2
Liquid Line (in.)
3
/8
Suction Line (in.)
7
/8
Estimated Charge (lbs)***
M4 M4E
8 ft 2.3 2.7
12 ft 3.3 3.9
***This is an average for all refrigerant
types actual refrigerant charge may vary
by approximately half a pound.
Length (in.) Added to Lineup
by Each End or Insulated
Partition 1
1
/
2
Impact
M4
Meat and Delecatessen
Multi-deck, 4 Display Levels
Dimensions shown as inches and (mm).
NSF Certification
These merchandisers are manufactured to meet ANSI /National