P/N_0486351_D
M3NX-GEP
Technical Data Sheet
P/N 0486351_D
NSF
®
Certified
March 2010
Item Part # Description Wiring Item #
FAN ASSEMBLIES
8 Ft & 12 Ft
A. 12W Standard Fan Assembly (1)
0047000 Fan Motor, Evaporator
(MO.4410103)
0461805 Fan Blade (FB.4780446)
12W Energy Efficient Fan Assembly (1)
0477655 Fan Motor, Evaporator
(MO.4410546)
0461805 Fan Blade (FB.4780446)
T
HERMOSTATS
B. Optional Adjustable Refrigeration Thermostat (2)
Item Part # Description Wiring Item #
L
AMPS AND BALLASTS
C. Ballast, Electronic (3)
0480130 2 lamps (BA.4481676)
0480131 3 lamps (BA.4481654)
0480132 4 lamps (BA.4481677)
D. Fluorescent Lamp (4)
Replace with like fixtures
LED F
IXTURES AND POWER SUPPLY
E. 0501213 Power Supply (EP.4481861) (5)
F. LED Canopy Fixture (6)
Replace with like fixtures — See Page 5.
G. LED Shelf Fixture (7)
Replace with like fixtures — See Page 5.
©2010 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
We reserve the right to change or revise specifications
and product design in connection with any feature of
our products. Such changes do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for equipment previously sold or shipped.
Note: Revision D adds EcoShine LED (page 4) and parts (page 5), and revises Btu note (page 3), canopy wiring diagram
(page 6). Other changes marked by bar, underline or circle.
2 of 10
M3NX-GEP Technical Data Sheet
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
Engineering
Plan Views
Wireway
26 3/4
(680)
25 1/4
(641)
37
(940)
A
41 1/2
(1054)
28 1/2
(724)
3 In.
(77 mm)
Required
Air Gap
Refrigeration
Outlet
Waste Outlet
Waste Outlet
FRONT
4 3/4 (120)
21 1/4
(540)
D
C
8 (203)
12 1/8 (307)
4 1/4 (108)
41 1/2
(1054)
43 7/8
(1114)
B
Splashguard
19
(483)
NOTE: Case-to-Case Electrical Connections
are made IN FRONT OF SPLASHGUARD.
Electrical
Stub Up Area
6 x 6
(152x152)
Electrical
Field
Connection
26 1/2
(673)
4 3/4 (120)
4 1/2 (115)
8 ft 12 ft
General
(A) Case Length (without ends or partitions) 96 3/
8 (2448) 144
1
/
2 (3670)
(Each end and insulated partition adds 1 1/
2 in. (38 mm) to case line up.)
Maximum O/S dimension of case back to front
(includes bumper) 37 (940) 37 (940)
Back of case to front of splashguard 28 1/
2 (724) 28
1
/
2 (724)
Back of case to O/S edge of front leg 25
1
/4 (641) 25 1/4 (641)
Distance between edges of external legs and center legs 41 1/2 (1054) 41 1/2 (1054)
Distance between edges of center legs NA 43 7/8 (1114)
Distance between front legs and splashguard 2 3/4 (70) 2 3/4 (70)
Electrical Service (Electrical Field Wiring connection point)
(B) RH End of case to center of stub up area 84 1/4 (2140) 132 3/8 (3363)
Back of case to center of stub up area 19 (483) 19 (483)
Length of electrical wireway 26 1/2 (673) 26 1/2 (673)
(C) RH End of case to LH end of wireway 90 1/8 (2289) 138 1/4 (3511)
Waste Outlets (One each end)
(D) RH End of case to the center of LH waste outlet 84 1/4 (2140) 132 3/8 (3363)
RH End of case to the center of RH waste outlet 12 1/
8 (307) 12
1
/
8 (307)
Back O/S of case to center of waste outlets 26
3
/4 (680) 26 3/4 (680)
Schedule 40 PVC drip pipe 1 1/4 (32) 1 1/4 (32)
Refrigeration Outlet
Back of case to center of refrigeration outlet 21 1/4 (540) 21 1/4 (540)
RH end of case to center of refrigeration outlet 8 (203) 8 (203)
Meat / Delicatessen
10-2004
M3NX
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/4
Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
7
/8
Dimensions shown as in. and (mm).
REFRIGERATION DATA
Note: This data is based on store temperature and
humidity that does not exceed 75°F and 55% R.H.
M3NX-GEP UNLIT LIT
Discharge Air °F 31 29
Evaporator °F 28 26
Unit Sizing °F 26 24
Btu/hr/ft
‡
— Unlit Shelves
‡‡
M3NX-GEP Parallel Conventional
U
NLIT 935 1035
‡
Optional energy efficient motors reduce the
refrigeration load by 27 Btu/hr/ft.
‡‡
Add 10 Btu/hr/ft per shelf row for LED fixtures.
Add 20 Btu/hr/ft per shelf row for fluorescent lamps.
DEFROST DATA
Frequency Hr 6
Defrost Water (lb/ft/day) 8
(± 15% based on case configuration and
product loading).
OFFTIME M3NX-GEP
Time (minutes) 30
ELECTRIC OR GAS Not Recommended
CONVENTIONAL CONTROLS
Low Pressure Backup Control
CI/CO* M3NX-GEP
19°F / 9°F
Indoor Unit Only,
Pressure Defrost Termination* 48°F
*Use a Temperature Pressure Chart to
determine PSIG conversions.
Estimated Charge** M3NX-GEP
8 ft 3.1 lb 50 oz 1.4 kg
12 ft 4.5 lb 72 oz 2.0 kg
**This is an average for all refrigerant types.
Actual refrigerant charge may vary by
approximately half a pound.
P/N 0486351_D
3 of 10
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
28 7/8
(734)
28 5/8
(727)
Refrigeration
Outlet
42 3/4
(1085)
34 5/8
(878)
FAN
C
O
I
L
M3NX-GEP
3 In. (77 mm)
Required
Air Gap
7 1/4 (183)
15
(381)
Electrical
Case to Case
Connections
26 3/4 (680)
25 1/4 (641)
37 (940)
28 1/2 (724)
21 1/4 (540)
4 3/4
(120)
12 1/4
(311)
74 3/8
(1890)
25
(635)
16 1/4
(413)
38 1/4
(972)
7 1/4
(184)
Dimensions shown as inches and (mm).
Narrow Footprint, Multi-deck, 3 Display Levels, and Glass Front
Impact
Excel
M3NX-GEP
Meat / Delicatessen
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF
(National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.