Hussmann M2GE Datasheet

B
D
C
E
D
A
E
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
P/N 0384134B
®
Note: Changed items have been underlined.
F
AN ASSEMBLIES AND THERMOSTATS
A. 6W Fan Assembly (1)
0058698 Fan Motor, Evaporator 0142780 Fan Blade
embossing toward motor
B. 0411744 Standard Non-adjustable (2)
Defrost Thermostat
C. 0137880 Optional Adjustable (3)
Refrigeration Thermostat
Item Part # Description Wiring Item #
LAMPS AND BALLASTS
D. 0428648 Ballast, Electronic
2 lamps (4)
D. 0428649 Ballast, Electronic
3 lamps (4)
E. Fluorescent Lamp (5)
Replace with like fixtures
M2GE
Data Sheet Set
P/N 0384134B
NSF
®
Certified
September, 2003
The M2G has been discontinued.
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
Merchandisers
8 ft 12 ft
General
(A) Case Length (without ends or partitions) 96 3/
8 (2448) 144
1
/
2 (3670)
Maximum outside dimension of case back to front
(includes bumper) 46
1
/
2 (1182) 46
1
/
2 (1182)
Back of case to front of splash guard 38
7
/
8 (986) 38
7
/
8 (986)
Back of case to outside edge of front skid rail 29
1
/4 (743) 29 1/4 (743) Width of skid rail 4 1/2 (114) 4 1/2 (114) Right-hand end of case to inside edge of external support 5 1/2 (140) 5 1/2 (140) Distance between edges of external support and center support 40 5/8 (1032) 40 5/8 (1032) Distance between edges of center supports NA 44 (1118) Stub-up area between front skid rail and splash guard 7 7/8 (199) 7 7/8 (199)
Electrical Service (Electrical Field Wiring connection point)
(B) Right-hand end of case to center of farthest knockout 88 3/8 (2245) 136 1/2 (3467)
Back outside of case to center of knockout 34 5/8 (881) 34 5/8 (881) Length of electrical raceway 34 1/2 (878) 34 1/2 (878)
Waste Outlet
(C) Left-hand end of case to the center of waste outlet 72 1/4 (1835) 72 1/4 (1835) (D) Right-hand end of case to the center of waste outlet 24 1/8 (613) 72 1/4 (1835)
Back outside of case to center of waste outlet 27 5/8 (702) 27 5/8 (702)
Water Seal
Edge of water seal to center of waste outlet 4 (102) 4 (102) Outside diameter of the drip pipe 1 1/
2 (38) 1
1
/
2 (38)
*Note: Water seal outlet must clear front skid rail. M2E & M2GE water seal rotation in forward direction only, due to low base.
Refrigeration Outlet
(E) Right-hand end of case to center of refrigeration outlet 9 (230) 9 (230)
Back of case to center of refrigeration outlet 30
5
/8 (778) 30 5/8 (778)
2 of 7
Engineering
Plan Views
Dimensions shown as inches and (mm).
M2GE Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Meat, Delicatessen
and Precut Produce
08-2003
A
B
M2GE
34 5/8
(881)
Electrical
C
Skid/ External Base
7 7/8 (199)
27
Waste Outlet
Water Seal
(See Note*)
Front
(703)
5
/8
D
5 1/2 (140)
29 1/4
(743)
30 5/8
(778)
E
4
(102)
Refrigeration
38 7/8
(986)
46 1/2
(1182)
3 of 7
P/N 0384134B
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
26 7/8 (683)
7 1/2 (190)
35 1/8
(894)
30 1/8
(766)
FAN
C O
I
L
55 1/4
(1402)
29 3/8
(746)
5 3/8
(136)
26
(661)
14 1/8
(360)
7 3/4
(199)
46 1/2 (1182)
38 3/4 (984)
29 1/4 (743)
27 3/4 (703)
34 3/4 (881)
Dimensions shown as inches and (mm).
Multi-deck, 3 or 4 Display Levels, with Front Glass
NSF Certification
These merchandisers are manufactured to meet ANSI /National Sanitation Foundation (NSF®) Standard #7 requirements.
Impact M2GE
Meat, Delicatessen,
and Pre-cut Produce
REFRIGERATION DATA
Note: This data is based on store temperature
and humidity that does not exceed 75°F and 55% R.H.
M2GE Discharge Air (°F) 29 Evaporator (°F) 21 Unit Sizing (°F) 19
Btu/hr/ft* M2GE Parallel 915 Conventional 985
*For all refrigeration equipment other than Hussmann, use conventional Btu values.
DEFROST DATA
M2GE Frequency (hr) 6 Defrost Water (lb/ft/day) 6
(± 15% based on case configuration and
product loading).
O
FFTIME
M2GE Temp Term (°F) 48°F Failsafe (minutes) 30
ELECTRIC OR GAS Not Recommended
Standard Defrost Thermostat
Close on rise: close 48°F — open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control
M2GE CI/CO** 14°F / 4°F
Indoor Unit Only, Pressure Defrost Termination** 48°F
**Use a Temperature Pressure Chart to determine PSIG conversions.
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/2 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
7
/8
Estimated Charge (lb)*** 8 ft 2.3 12 ft 3.3
***This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound.
Length (in.) added to Lineup by Each End or Insulated Partition 1
1
/2
The M2G has been discontinued.