Hussmann M1X-XGE Specifications

C
B
A
M1X-XGE
Technical Data Sheet
P/N 0475010_G
NSF
®
Certified
Item Part # Description Wiring Item #
FAN ASSEMBLIES 8 Ft & 12 Ft
A. 4W Standard Fan Assembly (1)
0392457 Fan Motor, Evaporator
(MO.4410101)
0464847 Fan Blade (FB.4780649) 4W Energy Efficient Fan Assembly (1) 0477653 Fan Motor, Evaporator
(MO.4410544)
0464847 Fan Blade (FB.4780649)
Item Part # Description Wiring Item #
THERMOSTATS
B. 0382028 Standard Non-adjustable (2)
Defrost Thermostat (CT.0382028)
C. Optional Adjustable
Refrigeration Thermostat (3)
LAMPS AND BALLASTS
None
©2010 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
Note: Revision G adds Btu note (page 3). Other changes marked by bar, underline or circle.
P/N_0475010_G
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
2 of 5 M1X-XGE Technical Data Sheet
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
Engineering
Plan Views
Meat, Delicatessen and Produce
09-2005
NOTE: Case-to-Case Electrical Connections are made IN FRONT OF SPLASHGUARD.
4 3/4 (120)
Splashguard
31 5/8
(804)
42
(1064)
A
41 1/2
(1054)
3 In.
(77 mm)
Required
Air Gap
Refrigeration
Outlet
Electrical
Stub Up Area
6 x 6
(152x152)
Waste Outlet
Waste Outlet
FRONT
26 1/4
(665)
B
D
8 (203)
4 1/2 (115)
12 1/8 (307)
41 1/2
(1054)
43 7/8
(1114)
C
Wireway
4 3/4 (120)
26 1/2
(673)
4 1/4 (108)
24
(612)
33 1/2
(851)
Electrical Field Connection
30 1/4
(768)
M1X
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/4 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
5
/8
8 ft 12 ft
General
(A) Case Length (without ends or partitions) 96 3/
8 (2448) 144
1
/
2 (3670)
(Each end and insulated partition adds 1 1/2 in. (38 mm) to case line up.)
Maximum O/S dimension of case back to front
(includes bumper) 42 (1064) 42 (1064)
Back of case to front of splashguard 33 1/2 (851) 33 1/2 (851) Back of case to O/S edge of front leg 30 1/4 (768) 30 1/4 (768) Distance between edges of external legs and center legs 41 1/2 (1054) 41 1/2 (1054) Distance between edges of center legs NA 43 7/8 (1114) Distance between front legs and splashguard 2 3/4 (70) 2 3/4 (70)
Electrical Service (Electrical Field Wiring connection point)
(B) RH End of case to center of stub up area 84 1/4 (2140) 132 3/8 (3363)
Back of case to center of stub up area 24 (612) 24 (612) Length of electrical wireway 26 1/2 (673) 26 1/2 (673)
(C) RH End of case to LH end of wireway 90 1/8 (2289) 138 1/4 (3511)
Waste Outlets (One each end)
(D) RH End of case to the center of LH waste outlet 84 1/
4 (2140) 132
3
/
8 (3363)
RH End of case to the center of RH waste outlet 12
1
/8 (307) 12 1/8 (307) Back O/S of case to center of waste outlets 31 5/8 (804) 31 5/8 (804) Schedule 40 PVC drip pipe 1 1/4 (32) 1 1/4 (32)
Refrigeration Outlet
Back of case to center of refrigeration outlet 26 1/4 (665) 26 1/4 (665) RH end of case to center of refrigeration outlet 8 (203) 8 (203)
Wireway
Dimensions shown as in. and (mm).
Loading...