Hussmann M1XLD-GE Specifications

C
B
A
E
D
F
C
M1XLD-GE
Technical Data Sheet
P/N 0490770_E
NSF
Certified
March 2010
©2010 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
Item Part # Description Wiring Item #
FAN ASSEMBLIES AND THERMOSTATS
A. 9W Standard Fan Assembly (1)
0440420 Fan Motor, Evaporator
(MO.4410302)
0376413 Fan Blade (FB.0376413)
0123592 Relay, DPDT 208V coil (4)
(RL.4440495)
0253603 Relay, DPDT 120V coil
(RL.4440267)
B. Optional Adjustable
Refrigeration Thermostat (2)
C. 0398557 Standard Non-adjustable (3)
Defrost Thermostat
(CT.4440611)
Item Part # Description Wiring Item #
HEATERS
D. 0483959 8 ft and 12 ft (5)
Modular Electric
Defrost Heaters, 208V, 685W
(HE.4850633)
E. Rear Rail Heaters (6)
0109417 8 foot case (HE.4850422)
0109418 12 foot case (HE.4850423)
F. 0483952 Front Glass Anti-Sweat Heater (7)
(GL.4978826)
LAMPS AND BALLASTS
None
Note: Revision E adds Btu note (page 3). Other changes marked by bar, underline or circle.
P/N_0490770_E
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
M1XLD-GE Technical Data Sheet2 of 7
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
Engineering
Plan Views
Dimensions shown as in. and (mm).
Frozen Meat, and Delicatessen
09-2005
NOTE: Case-to-Case Electrical Connections are made IN FRONT OF SPLASHGUARD.
4 3/4 (120)
Splashguard
31 5/8
(804)
42
(1064)
A
41 1/2
(1054)
3 In.
(77 mm)
Required
Air Gap
Refrigeration
Outlet
Electrical
Stub Up Area
6 x 6
(152x152)
Waste Outlet
Waste Outlet
FRONT
26 1/4
(665)
B
D
8 (203)
4 1/2 (115)
12 1/8 (307)
41 1/2
(1054)
43 7/8
(1114)
C
Wireway
4 3/4 (120)
26 1/2
(673)
4 1/4 (108)
24
(612)
33 1/2
(851)
Electrical Field Connection
30 1/4
(768)
8 ft 12 ft
General
(A) Case Length (without ends or partitions) 72 3/
8 (1838) 96
3
/
8 (2448) 144
1
/
2 (3670)
(Each end and insulated partition adds 1 1/2 in. (38 mm) to case line up.)
Maximum O/S dimension of case back to front
(includes bumper) 42 (1064) 42 (1064) 42 (1064)
Back of case to front of splashguard 33 1/2 (851) 33 1/2 (851) 33 1/2 (851) Back of case to O/S edge of front leg 30 1/4 (767) 30 1/4 (768) 30 1/4 (768) Distance between edges of external legs and center legs 29 1/2 (750) 41 1/2 (1054) 41 1/2 (1054) Distance between edges of center legs NA NA 43 7/8 (1114) Distance between front legs and splashguard 2 3/
4 (70) 2
3
/
4 (70) 2
3
/
4 (70)
Electrical Service (Electrical Field Wiring connection point)
(B) RH End of case to center of stub up area 60
1
/
4 (1530) 84
1
/
4 (2140) 132
3
/
8 (3363)
Back of case to center of stub up area 24 (612) 24 (612) 24 (612) Length of electrical wireway 26
1
/2 (673) 26 1/2 (673) 26 1/2 (673)
(C) RH End of case to LH end of wireway 66 1/
8 (1680) 90
1
/
8 (2289) 138
1
/
4 (3511)
Waste Outlets (One each end)
(D) RH End of case to the center of LH waste outlet 60
1
/
4 (1530) 84
1
/
4 (2140) 132
3
/
8 (3363)
RH End of case to the center of RH waste outlet 12
1
/8 (307) 12 1/8 (307) 12 1/8 (307)
Back O/S of case to center of waste outlets 31 5/
8 (804) 31
5
/
8 (804) 31
5
/
8 (804)
Schedule 40 PVC drip pipe 1
1
/
4 1
1
/
4 (32) 1
1
/
4 (32)
Refrigeration Outlet
Back of case to center of refrigeration outlet 26
1
/
4 (665) 26
1
/
4 (665) 26
1
/
4 (665)
RH end of case to center of refrigeration outlet 8 (203) 8 (203) 8 (203)
Wireway
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/4 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
5
/8
REFRIGERATION DATA
Note: This data is based on store temperature and humidity that does not exceed 75°F and 55% R.H.
M1XLD-GE
Discharge Air (°F) –10
Evaporator (°F) –20
Unit Sizing (°F) –23
Btu/hr/ft
M1XLD-GE
Parallel 380
Conventional 390
Energy efficient fan motors are not available for
this low temperature model.
DEFROST DATA
M1XLD-GE
Frequency (hr) 8
ELECTRIC
Temp Term (°F) 48°F
Failsafe (minutes) 40
GAS W/REVERSE AIR
Duration (minutes) 15
Standard Defrost Thermostat
Close on rise: close 48°F — open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control
M1XLD-GE
CI/CO* –27°F / –37°F
Indoor Unit Only, Pressure Defrost
Termination* Not Recommended
*Use a Temperature Pressure Chart to determine PSIG conversions.
Estimated Charge** M1XLD-GE
8 ft 1.7 lb 27 oz 0.8 kg
12 ft 2.3 lb 37 oz 1.0 kg
**This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound.
3 of 7
P/N 0490770_E
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
4 3/4
(120)
17 1/8
(436)
39 1/8
(994)
31 5/8 (804)
30 1/4 (768)
42 (1064)
33 1/2 (851)
26 1/4 (665)
Electrical
Case to Case
Connections
FAN
C O
I
L
3 In.
(77 mm)
Required
Air Gap
Refrigeration Outlet
28 5/8
(727)
38 1/4
(972)
12 1/4
(311)
7 5/8
(194)
9 3/4 (246)
30 (762)
2 1/8
(54)
8 3/4
(222)
32 3/8 (822)
M1XLD-GE
11
(280)
13 3/8 (340)
Dimensions shown as inches and (mm).
Single Deck, 1 Display Level, Deep, Glass Front
Impact
Excel
M1XLD-GE
Frozen Meat and
Delicatessen
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.
Loading...