Hussmann M1GLE-93 Technical Data Sheet

Page 1
P/N 0405077_B
®
M1GLE-93
P/N 0405077_B
NSF
®
Certified
July 2007
Item Part # Description Wiring Item #
FAN ASSEMBLIES, AND THERMOSTATS
A. 9W Fan Assembly (1)
0302555 Fan Motor,
EMS #RS4BEB9E1 (MO.0302555)
0252116 Fan Blade
embossing toward motor 7 Inch, 15°, CW (FB.4780611)
B. Optional Adjustable Refrigeration Thermostat, (2)
C. 0398557 Defrost Termination (3)
Thermostat, Disc type 48° F (CT.4440611)
Item Part # Description Wiring Item #
R
ELAYS
D. 0123592 Relay, DPDT 208V coil (4)
(RL.4440495)
0253603 Relay, DPDT 120V coil (4)
(RL.4440267)
HEATERS
E. 008671P Modular Electric
Defrost Heaters, 208V, 514W (5) (HE.4850419)
F. Rear Rail Heaters, 120V, 6 amp (6)
0494977
93 inch end cap case (HE.4850716)
NOTE:
The M1GLE-93, is a low or dual temperature island end cap case, designed to be used with back to back C2LG cases with 4 in. elevated bases.
NOTE: Changed items have been underlined.
©2007 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
Merchandisers
C
A
B
D
F
E
Page 2
M1GLE-93 Technical Data Sheet 2 of 6
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Dimensions shown as inches and (mm).
Engineering
Plan View
End
General
(A) Case Length (bumper to bumper) 93 (2362)
Maximum O/S dimension of case back to front (includes bumper) 43 1/2
(1105)
Back of case to front of splashguard 31
5
/8 (810) Back of case to O/S edge of front skid rail 26 1/4 (667) Width of skid rail 4 1/2
(114)
Stub-up area between front skid rail and splashguard 4 (102)
Electrical Service (Electrical Field Wiring connection point)
(B) RH End of case to center of farthest knockout 83
3
/8 (2118)
Back O/S of case to center of knockout 27 1/4 (692)
Waste Outlet
(C) RH End of case to the center of waste outlet 31 1/4 (794)
LH End of case to the center of waste outlet 61 3/4 (1569) Back O/S of case to center of waste outlet 24 1/4 (616)
Water Seal
Edge of water seal to center of waste outlet 4 (102) Outside diameter of the drip pipe 1 1/
2 (38)
NOTE: Water seal outlet must clear front skid rail.
Refrigeration Outlet
Back O/S of case to center of refrigeration outlet 27
3
/8 (695)
(D) RH end of case to center of refrigeration outlet 161/2 (419)
09-1997
Frozen Meat or Delicatessen
A
B
61 3/4 (1569)
C
17 1/8
(435)
4 1/2 (114)
27 1/4
(692)
Access Area
Electrical
(see note*)
4 (102)
Front
24 1/4
(616)
Waste Outlet
Water Seal
(see note**)
27 3/8
(695)
D
Refrig.
Outlet
26 1/4
(667)
31 5/8
(810)
43 1/2
(1105)
Page 3
3 of 6P/N 0405077_B
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
REFRIGERATION DATA
M1GLE-93
Discharge Air °F –10*
Evaporator °F –20*
Unit Sizing °F –23
B
TU
/HR/FOOT
M1GLE-93
Parallel 730†
Conventional 760†
DEFROST DATA
Frequency Hrs 6
E
LECTRIC
M1GLE-93 Temp Term °F 48 Failsafe Minutes 40
G
AS
Duration (Minutes) 15
O
FFTIME
Not Recommended
CONVENTIONAL CONTROLS
Low Pressure Backup Control
M1GLE-93
CI/CO (Temp °F)** –27 / –37
Indoor Unit Only, Pressure Defrost Termination (Temp °F)**
Not Recommended
**Use a Temperature Pressure Chart to determine PSIG conversions.
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1
1
/4
Liquid Line (in.)
3
/8
Suction Line (in.)
5
/8
Estimated Charge (lbs)*** M1GLE-93 1.7
***This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound.
DUAL TEMPERATURE CASE APPLICATIONS
*Medium temperature operation: Discharge Air °F –21
Evaporator °F –10
†Multiply by 6 feet.
Impact M1GLE-93
Frozen Meat or Delicatessen
Single Level Wall Island Display
Dimensions shown as in. & (mm).
NSF Certification
These merchandisers are manufactured to meet ANSI /National
Sanitation Foundation (NSF
®
) Standard #7 requirements.
M1GLE-93
11
3
29
/
4
(756)
1
28
/
2
(724)
3
6
(171)
/
4
(289)
3
15
/
7
29
/
8
(759)
3
/
8
(400)
4
C
10
O
(254)
I
L
34
(889)
7
FAN
7
9
/
16
(239)
3 7/
4
(102)
43
1
/
32
(1103)
2
26
1
/
24
2
3
/
4
(826)
3
/
(679)
(619)
8
(98)
8
/
8
Page 4
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
M1GLE-93 Technical Data Sheet 4 of 6
Impact
M1GLE-93
Frozen Meat or Delicatessen
Electrical Data
End
Number of Fans – 9W 2
Amperes Watts
Merchandiser
End End
Fans
Standard NA Energy Efficient NA Reverse Air 0.60 60
Anti-sweat Heaters
Constant on Anti-sweat Heaters 0.60 72
Cycling Anti-sweat Heaters NA
Min. Circuit Ampacity
With Standard Fans NA With Energy Efficient Fans NA With Reverse Air Fans 1.5
Max. Over Current Protection 20
208V Electric Defrost 5.0 1040 120V Supplemental Rev. Air NA
Standard Lighting
None
Optional Lighting
None
Standard Shelf Lighting
None
Page 5
5 of 6P/N 0405077_B
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
L2
L3
L1
L2
Modular Electric Defrost Heaters
(Mounted above Evaporators)
R
R
5
Defrost Termination Thermostat
Refrigeration
Thermostat
Dark Blue
To Condensing Unit
}
Light Blue
32
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
Circled Numbers = Parts List Item Numbers.
R = Red
Evaporator Fans (Reverse During Defrost)
1
4
Orange
Red
Brown
To Defrost Timer
120V Only
Blue
Yellow
Relay
Electric Defrost – Standard
120V
P
OWER
Anti-Sweat Heater, Rear Rail
6
PURPLE BAND
PURPLE BAND
120V
N
EUTRAL
1
3
2
208 V Power From Defrost Contactors
Electric Defrost – Standard
Page 6
Gas Defrost – Optional
M1GLE-93 Technical Data Sheet 6 of 6
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
L2
L3
Refrigeration
Thermostat
To Condensing Unit
}
Light Blue
2
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
Circled Numbers = Parts List Item Numbers.
120V
P
OWER
Anti-Sweat Heaters, Rear Rail
6
PURPLE BAND
PURPLE BAND
120V
N
EUTRAL
Evaporator Fans (Reverse During Defrost)
1
4
Orange
Red
Brown
To Defrost Timer
120V Only
Blue
Yellow
Relay
1
3
2