REAR
Field Connection
Terminal Block
Terminal Block
F
F
G
L
E
Terminal
Block
G
Serial Plate
(Interior Top Panel)
L
M
M
F
G
J
E
I
LifeLine Premier
RLNIE
with
INNOVATOR
Doors
Technical Data Sheet
P/N 0510312_B
NSF
®
Certified
June 2010
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
OPTION SHOWN:
• Lighted Facades
WARNING
Terminal
block NOT for
case-to-case
wire
connection!
P/N0510312B
©2010 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
NOTE: Revision B adds Facade Lighting values on page 6, updates wiring item numbers on pages 1, 8, 14 & 15 and updates pages 1, 3,
4 & 5. Changes are underlined, circled or marked with a vertical line in the margin.
Item Part # Description Wiring Item #
F
AN ASSEMBLIES, AND THERMOSTATS
A. 12W Standard Fan Assembly (1)
MO.4410103 Fan Motor, Evaporator FB.4780446 Fan Blade 12W Optional Energy Efficient Fan Assembly (1) MO.4410546 Fan Motor, Evaporator FB.4780446 Fan Blade
B. CT.4440726 Standard Non-adjustable Defrost (2)
Thermostat C. Optional Adjustable Refrigeration Thermostat (3) D. CT.4440261 Defrost Limit Thermostat (4)
E. CT.4481296 Relay Control Thermostat or (5)
Fan and Anti-sweat Heater Thermostat
RELAYS
F. RL.4480238 Anti-Sweat Control Relay (120V) (6)
G. Fan Control Relay (7)
RL.4480237 (208V) Electrical Defrost RL.4480238 (120V) KoolGas Defrost
Item Part # Qty Description Wiring Item #
H
EATERS
H. HE.4850346 (2) Electric Defrost Heater – Front (208V) (8)
HE.4850358 (2) Electric Defrost Heater – Rear (208V) (8) HE.4850502 (2) Electric Defrost Heater – End (208V) (8)
I. HE.4850240 (2) Drain Pan Heater (120V) (9)
Electric & KoolGas
J HE.4850573 Flue Reheater (120V) (10)
LED F
IXTURES AND POWER SUPPLY
K. EP.4481668 Power Supply (11)
L. Door Lamp, LED
BU.4440875 3500K Center (12) BU.4440877 4100K Center (12) BU.4440876 3500K End (13) BU.4440878 4100K End (13)
M. Facade Lamp, LED (14)
BU.4441411 2900K 29.5 In. Length BU.4441412 2900K 30.5 In. Length
NOTE: For LED lighting parts contact your Hussmann service representative at 1-800-922-1919. Please have your model and serial number available.
Refer to I
NNOVATOR REACH-IN GLASS DOOR
I
NSTALLATION AND SERVICE
manual, P/N 0425683, for Innovator and Innovator II door and frame replacement parts.
Page 2
LifeLine Premier
RLNIE with Innovator Doors
Technical Data Sheet
2 of 15
U.S. & Canada 1-800-922-1919 • Mexico 1-800-522-1900
6
(152)
Wate r
Seal
Waste Outlet
Electrical Wireway
Electrical Wireway
Waste Outlet
Electrical Wireway
88 1/2
(2248)
9 1/8
(232)
Relay & Terminal Block Location
Refrigeration Outlet
60 5/8
(1540)
63 1/4
(1607)
70 1/8
(1782)
72 3/8
(1838)
1 3/4 (44)
4 (102)
54 1/4
(1378)
5 5/8
(143)
38 1/4
(972)
99 3/4
(2534)
48
(1219)
Main Field Connection
Electrical Terminal Block
REAR OF CASE
FRONT OF CASE
Relay &
Terminal
Block
Location
Relay & Terminal Block Location
Splashguard
7
(178)
Clearance for Door Swing
26
1
/2
(673)
26
1
/2
(673)
26
1
/2
(673)
Clearance for Door Swing
125 3/8
(3185)
126 1/4
(3207)
Clearance for Door Swing
Reach-In
Narrow Island
Unitized End
Engineering
Plan Views
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/4 Merchandiser Liquid Line (in.)
5
/8
Merchandiser Suction Line (in.) 1 1/8
LifeLine Premier
RLNIE
Plan View
05-2010
Unitized Island End merchandiser is shown above. Neither Bump Out nor Dry Goods available on island end
models. Refer to chart on Page 3 for detailed dimensional information.
Dimensions shown as inches and (mm).
Page 3
3 of 15P/N 0510312_B
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
LifeLine Premier
RLNIE
With INNOVATOR Doors
Frozen Food & Ice Cream
Plan View Dimensions for
LifeLine Premier
Options
RLNIE
General
(A) Merchandiser Length 99 3/4 (2534)
Maximum O/S dimension of merchandiser back to front *** 72 3/8
(1838)
*** Includes bumper. Add 53 in. (1346 mm) for door swing.
Width of skid rail 3 3/4
(95) Width of Bottom Front Support 6 (152) Stub-up area between front support and splashguard 9 (229)
Electrical Service* (B) RH end of merchandiser to the center of nearest knockout 4 (102)
RH end of merchandiser to the center of LH knockout 88
1
/
2 (2248)
* NOTE: Electrical Field Wiring Connection Point is at terminal.
Waste Outlet
(C) Right end of merchandiser to center of waste outlet 38 1/
4 (972)
RH end of merchandiser to center of waste outlet in front of case 54
1
/4 (1378)
Back O/S of merchandiser to center of waste outlet 63 1/4 (1607)
Water Seal
Edge of water seal to center of waste outlet 13 (330) Schedule 40
diameter of drip piping 1
1
/
4 (32)
Field installed water seal outlets, tees, and connectors are shipped with case.
Refrigeration Outlet
(D) RH end of merchandiser to center of RH refrigeration outlet 5 5/8 (143)
Back O/S of merchandiser to center of refrigeration outlet 60 5/
8 (1540)
Outside bottom front supports from end of merchandiser 7 (178) Center bottom front support from Centerline 48 (1219)
Page 4
Facade (Installed Position)
Facade (Shipping Position)
12 1/8
(308)
12 in. Straight Facade
87 1/2
(2222)
Shipped
94 1/2
(2401)
Installed
Facade (Installed Position)
Facade (Shipping Position)
18 1/8
(460)
18 in. Straight Facade
87 1/2
(2222)
Shipped
100 1/2
(2553)
Installed
LifeLine Premier
RLNIE with Innovator Doors
Technical Data Sheet
4 of 15
U.S. & Canada 1-800-922-1919 • Mexico 1-800-522-1900
LifeLine Premier
RLNIE
With INNOVATOR Doors
Frozen Food & Ice Cream
Facade Options in Cross Section ( Arched Facade Not Available )
Island End Profile
Page 5
LifeLine Premier
RLNIE
With INNOVATOR Doors
Frozen Food & Ice Cream
Facade (Installed Position)
Facade (Shipping Position)
18 1/8
(460)
18 in. Straight Facade
Shown
72 (1838)
70 (1778)
4
(121)
11
(298)
67
(1702)
Frame
65 1/2
(1664)
Door
82 1/4
(2089)
13 1/8
(333)
Frame
6
1
/4
(159)
63 (1607)
60 (1540)
3 1/2
(89)
9
(232)
2 1/8
(55)
Facade (Installed Position)
18 1/8
(460)
87 1/2
(2222)
Shipped
100 1/2
(2553)
Installed
82 1/4
(2089)
Dimensions shown as inches and (mm).
LifeLine Premier
Reach-in Narrow Island,
End and Center Unitized
5 of 15P/N 0510312_B
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.
LifeLine
Premier
RLNIE
See Page 4 for alternate facade heights.
REFRIGERATION DATA
Note: This data is based on store temperature and
humidity that does not exceed 75°F and 55%
R.H.
FF IC Discharge Air (°F) 0 –11 Evaporator (°F) –11 –19 Unit Sizing (°F) –14 –22
Btu/hr/case † ‡ FF IC
Parallel
8,900 9,200
Conventional
9,100 9,400
Optional Energy Efficient Fan motors
reduce refrigerant load by 654 Btu/hr/case.
‡Includes EcoShine LED lighting.
DEFROST DATA
FF IC Frequency (hr) 24 24 Defrost Water (lb/day) 8.6 8.6
(± 15% based on case configuration and prod-
uct loading).
E
LECTRIC
FF IC Temp Term (°F) 48 48 Failsafe (minutes) 45 45
GAS
Duration (minutes) 20 20
OFFTIME Not Recommended
Standard Defrost Thermostat
Close on rise: close 48°F — open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control
FF IC CI/CO (Temp °F)* –18/–34 –26/–45 Indoor Unit Only, Pressure Defrost Termination (Temp °F)*
Not Recommended
*Use a Temperature Pressure Chart to deter-
mine PSIG conversions.
Estimated Charge **
RLNIE 5.4 lb 86 oz 2.4 kg
**This is an average for all refrigerant types.
Actual refrigerant charge may vary by approx-
imately
0.5 lb (8 oz / 0.2 kg).
Length added to Lineup by: Each Standard End (in.) 2 Insulated Partition (in.) 1
1
/2
Page 6
Electrical Data
Number of Fans – 12W RLNIE
7
Amperes Watts Merchandiser Evaporator Fans
120V 60Hz Standard 4.55 350 120V 50Hz Standard 5.25 399 220V 60Hz Export 2.31 350 220V 50Hz Export 2.66 399 120V 60Hz Energy Efficient 2.10 126 220V 60Hz Energy Efficient 1.05 126
Door Anti-sweat Heaters (on fan circuit)
120V 50/60Hz Standard 6.17 740 220V 50/60Hz Export 3.36 744
Frame Anti-sweat Heaters (on fan circuit)
120V 50/60Hz Standard 3.14 376 220V 50/60Hz Export 1.71 376
Frame Anti-sweat Heaters (on fan circuit)
120V 50/60Hz Standard 1.67 200 220V 50/60Hz Export 0.87 200
Minimum Circuit Ampacity
120V 60Hz Standard 15.73 120V 50Hz Standard 16.43 220V 60Hz Export 8.45 220V 50Hz Export 8.80 120V 60Hz Energy Efficient 13.28 220V 60Hz Energy Efficient 7.19
Maximum Over Current Protection 120V 20 Maximum Over Current Protection 220V 15
Defrost
Drain Heaters (120V 60Hz) 1.89 225 Export (230V 50Hz) 1.02 252
Electric Defrost (208V 3 Phase
))
per phase value 11.70 2426
Standard LED Lighting
Hussmann EcoShine [120V] 1.58 189 Hussmann EcoShine [220V (Export)] 0.86 189
Optional LED Lighting (24VDC)
Facade Lamps 3.07 73
* Innovator or Innovator II
U.S. & Canada 1-800-922-1919 • Mexico 1-800-522-1900
LifeLine Premier
RLNIE with Innovator Doors
Technical Data Sheet
6 of 15
LifeLine Premier
RLNIE
With
INNOVATOR Doors
Frozen Food & Ice Cream
Hussmann recommends against frame heater cycling with
Innovator
doors to prevent door seals from freezing to the
frames and tearing.
Page 7
7 of 15P/N 0510312_B
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
LifeLine Premier
RLNIE
With INNOVATOR Doors
Frozen Food & Ice Cream
ESTIMATED SHIPPING WEIGHT
5
Case
RLNIE
lb (kg) 1980 (900)
5
Actual weights will vary according to optional kits included.
Product Data
Recommended Usable Cube
1
(Cu Ft/Case) 148.52 ft3 /Case ( 4.21 m3 /Case)
AHRI Total Display Area
2
(Sq Ft/Case) 131.90 ft2/Case (12.25 m2 /Case)
Shelf Area 3(Sq Ft/Case) 185.65 ft2/Case (17.25 m2 /Case)
1
AHRI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume/Unit of Length, ft3/ft [m3/m]
2
Computed using AHRI 1200 standard methodology: Total Display Area, ft2[m2]/Unit of Length, ft [m]
3
Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann Product Reference Guide. The standard shelf complement for this model is (5) rows of 22-inch shelves.
Page 8
LifeLine Premier
RLNIE with Innovator Doors
Technical Data Sheet
8 of 15
U.S. & Canada 1-800-922-1919 • Mexico 1-800-522-1900
Defrost Termination
Thermostat
Refrigeration
Thermostat
(Optional)
Pink
2
3
}
To Condensing Unit
Terminal Blocks in Front and Rear Raceway
Low Temperature with
Electric Defrost
20
21
22
26
17
1234
56 7
81011 1413 16
LIGHTS
(120V)
DEFROST HEATERS
(208V)
CAUTION: When multiplexing merchandisers equipped with defrost heaters, if branch circuit overcurrent protection is larger than the
circuit load, then additional supplemental overcurrent protection may be required per NEC Articles 210 and 240.
RLNIE Front and Rear Compartment
24 2512
FANS & A.S.
(120V)
LIGHTS
(Neutral)
FANS & A.S. (Neutral)
Permanent Internal
Jumpers
R P
W
BRORRRRBKBKRRBKP
2P
BK BK ORBK 2P Y
Removable External
Jumpers
Dark Blue
Refer to Innovator Reach-In
Glass Door, Installation and Service manual, P/N 0425683,
for Innovator door and frame replacement parts.
Switch
17
20
120V
NEUTRAL
OR
OR
Defrost Termination Thermostat
FIELD WIRED
C.O.R.
DB
DB
Rear Defrost
Front Defrost
Defrost Limit
O.O.R.
1
2
3
8
7
6
4
5
Fan Relay Coil
208V
F
208V
R
R
R
7
1
3
R
BK
R
R
8
8
4
BK
Rod Heater (Drain)
Fans
NC
NO
F
F
Fan Relay
Relay Control
C.O.R.
A.S. Relay Coil
14
16
24
25
26
NC
AS
A.S. Relay
Frame A.S.
Door A.S.
13
10
11
12
22
21
AS
120V
Y
W
BR
1
9
7
7
Y
31
BK
5
6
P
2P
2P
P
6
BK
COM
BK
BK
NEUTRAL
ROD HEATER (Drain)
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
THESE ARE MARKER COLORS (WIRE MAY VARY.)
R = Red P = Purple 2P = Purple (2 Bands) DB = Dark Blue BK = Black
LB = Light Blue BR =Brown Y =Yellow OR = Orange W = White
Front and Rear Compartments Connect to Main Terminal Block at Rear (see Page 10).
Wiring Diagram is per side — two circuits required per case.
Wiring Diagram is per side — two circuits required per case.
Page 9
9 of 15P/N 0510312_B
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Defrost Termination
Thermostat
Refrigeration
Thermostat
(Optional)
Pink
2
3
}
To Condensing Unit
Terminal Blocks in End Raceway
Low Temperature with
Electric Defrost
20
21
22
26
17
1234
56 7
81011 1413 16
LIGHTS
(120V)
DEFROST HEATERS
(208V)
CAUTION: When multiplexing merchandisers equipped with defrost heaters, if branch circuit overcurrent protection is larger than the
circuit load, then additional supplemental overcurrent protection may be required per NEC Articles 210 and 240.
RLNIE End Compartment
24 2512
FANS & A.S.
(120V)
LIGHTS
(Neutral)
FANS & A.S. (Neutral)
Permanent Internal
Jumpers
R P
W
BRORRRRBKBKRRBKP
2P
BK BK ORBK 2P Y
Removable External
Jumpers
Dark Blue
Refer to Innovator Reach-In
Glass Door, Installation and Service manual, P/N 0425683,
for Innovator door and frame replacement parts.
Rear Defrost
Front Defrost
Defrost Limit
O.O.R.
1
2
3
8
7
6
4
5
Fan Relay Coil
208V
F
208V
R
R
R
13
7
R
BK
4
R
R
8
8
Fans
COM
NC
NO
F
F
Fan Relay
Relay Control
C.O.R.
A.S. Relay Coil
14
16
24
25
26
NC
AS
A.S. Relay
Frame A.S.
Door A.S.
13 10
11
12
22
21
AS
120V
Neutral
Reheater
7
7
1
5
6
BR
W
3
1
BK
P
2P
6
P
2P
10
BK
BK
BK
Switch
17
20
NEUTRAL
OR
OR
Defrost Termination Thermostat
FIELD WIRED
C.O.R.
DB
DB
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
THESE ARE MARKER COLORS (WIRE MAY VARY.)
R = Red P = Purple 2P = Purple (2 Bands) DB = Dark Blue BK = Black
LB = Light Blue BR =Brown Y =Yellow OR = Orange W = White
BK
End Compartment Connects to Main Terminal Block at Rear (see Page 10).
Page 10
Defrost Heaters (208v)
Defrost Heaters (208v)
Fans & AS (120v)
Light (120v)
Light (Neutral)
Fans & AS (Neutral)
Defrost Heaters (208v)
Defrost Heaters (208v)
Fans & AS (120v)
Light (120v)
Light (Neutral)
Fans & AS (Neutral)
Defrost Heaters (208v)
Defrost Heaters (208v)
Fans & AS (120v)
Light (120v)
Light (Neutral)
Fans & AS (Neutral)
Defrost Heaters (208v)
Defrost Heaters (208v)
Defrost Heaters (208v)
Fans & AS (120v)
Light (120v)
Fans & AS (Neutral)
Light (Neutral)
Field Connections
Front of Case
(Three door Frame)
End Case
(Two door Frame)
Rear of Case
(Three door Frame)
Ph. A (208v)
Main Field Electrical Connection Rear of Case
(Terminal Block Located in RH Doorframe wireway)
Standard RL terminal blocks
in door frame wireway.
Main terminal block located in
Rear wireway.
1
2
3
4
5
6
7
8
10
11 12
13
14
16
17
20
21
22
24
25
26
1
2
34
5
6
7
8
10
11 12
13
14
16
17
20
21
22
24
25
26
1
2
3
4
5
6
7
8
10
11
12
13
14
16
17
20
21
22
24
25
26
Ph. B (208v)
Ph. C (208v)
Fans & AS (120v)
Lights (120v)
Fans & AS (Ntrl)
Lights (Ntrl)
RLNIE Wiring Diagram for Electric Defrost
Front of Case
(Three door Frame)
End of Case
(Two door Frame)
Rear of Case
(Three door Frame)
LifeLine Premier
RLNIE with Innovator Doors
Technical Data Sheet
10 of 15
U.S. & Canada 1-800-922-1919 • Mexico 1-800-522-1900
Electric Defrost Sequence - Low Temperature
1. Power from the defrost contactor energizes Defrost Heaters and 208V Evaporator Fan Relay Coil (7). Relay Contacts open the fan
circuit and energizes the Drain Pan Heater.
2. If the Defrost Heater raises internal air temperature above 90°F, the Defrost Limit Thermostat (4) will open.
3. Temperature rise of the evaporator closes the Relay Control Thermostat (5) at about 35°F, energizing 120V A.S. Relay Coil (6). This
relay’s contacts open the Frame and Door Heater Circuits.
4. When Defrost Termination Thermostat ends defrost period, the defrost contactor opens the Defrost Heater and Evaporator Fan Relay
Coil Circuits. The Drain Pan Heater goes off and fans are on.
5. Temperature fall of the evaporator opens the Relay Control Thermostat (5) at about 20°F, de-energizing 120V A.S. Relay Coil (6).
A.S. Relay Contacts close the Frame and Door Heater Circuits.
LifeLine Premier
RLNIE
With INNOVATOR Doors
Frozen Food & Ice Cream
Page 11
11 of 15P/N 0510312_B
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Permanent Internal
Jumpers
A.S. Relay
Coil
BR
Evaporator Fans
1
Fan Relay
F
COM
N.O.
Rod Heater (Drain)
9
Y
Y
N.C.
7
7
1
3
W
Relay Control
c
25
Fan Relay
F
5
6
COM
N.C.
6
A.S. Relay
A.S.
24
Door A.S. Heaters
Frame A.S. Heaters
22
2P
2P
P
12
10
120V POWER
13
26
C.O.R.
P
OR
120V POWER
OR
Switch
NEUTRAL
17
20
Terminal Blocks in Raceway
Low Temperature with
Gas Defrost
20
21
22
26
17
10 11 1413 16
LIGHTS
(120V)
Refrigeration
Thermostat
(Optional)
Pink
3
}
To Condensing Unit
24 2512
FANS & A.S.
(120V)
LIGHTS
(Neutral)
FANS & A.S. (Neutral)
P
W
BRORBK P
2P
BK BK ORBK 2P Y
Removable External
Jumpers
RLNIE Front and Rear Compartment
16
7
Fan Relay
Coil
11
c
Defrost Limit
4
O.O.R.
14
21
NEUTRAL
Refer to Innovator Reach-In Glass Door, Installation and Service manual, P/N 0425683,
for Innovator door and frame replacement parts.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
THESE ARE MARKER COLORS (WIRE MAY VARY.)
R = Red P = Purple 2P = Purple (2 Bands) DB = Dark Blue BK = Black
LB = Light Blue BR =Brown Y =Yellow OR = Orange W = White
BK
BK
BK
BK
Front and Rear Compartments Connect to Main Terminal Block at Rear (see Page 13).
Wiring Diagram is per side — two circuits required per case.
Wiring Diagram is per side — two circuits required per case.
Page 12
LifeLine Premier
RLNIE with Innovator Doors
Technical Data Sheet
12 of 15
U.S. & Canada 1-800-922-1919 • Mexico 1-800-522-1900
Reheater
10
Permanent Internal
Jumpers
A.S. Relay
Coil
BR
Evaporator Fans
1
Fan Relay
F
COM
N.O.
N.C.
7
7
1
3
W
Relay Control
c
25
Fan Relay
F
5
6
COM
N.C.
6
A.S. Relay
A.S.
24
Door A.S. Heaters
Frame A.S. Heaters
22
2P
2P
P
12
10
120V POWER
13
26
C.O.R.
P
OR
120V POWER
OR
Switch
NEUTRAL
17
20
Terminal Blocks in Raceway
Low Temperature with
Gas Defrost
20
21
22
26
17
10 11 1413 16
LIGHTS
(120V)
Refrigeration
Thermostat
(Optional)
Pink
3
}
To Condensing Unit
24 2512
FANS & A.S.
(120V)
LIGHTS
(Neutral)
FANS & A.S. (Neutral)
P
W
BRORBK P
2P
BK BK ORBK 2P Y
Removable External
Jumpers
RLNIE End Compartment
16
7
Fan Relay
Coil
11
c
14
21
NEUTRAL
Refer to Innovator Reach-In Glass Door, Installation and Service manual, P/N 0425683,
for Innovator door and frame replacement parts.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
THESE ARE MARKER COLORS (WIRE MAY VARY.)
R = Red P = Purple 2P = Purple (2 Bands) DB = Dark Blue BK = Black
LB = Light Blue BR =Brown Y =Yellow OR = Orange W = White
BK
BK
BK
BK
End Compartment Connects to Main Terminal Block at Rear (see Page 13).
Page 13
13 of 15P/N 0510312_B
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Fans & AS (120v)
Light (120v)
Light (Neutral)
Fans & AS (Neutral)
Fans & AS (120v)
Light (120v)
Light (Neutral)
Fans & AS (Neutral)
Fans & AS (120v)
Light (120v)
Light (Neutral)
Fans & AS (Neutral)
Fans & AS (120v)
Light (120v)
Fans & AS (Neutral)
Light (Neutral)
RLNIE Wiring Diagram for Gas Defrost
Main Field Electrical Connection Rear of Case
(Terminal Block Located in RH Doorframe wireway)
Front of Case
(Three door Frame)
End Case
(Two door Frame)
Rear of Case
(Three door Frame)
Fans & AS (120)
Standard RL terminal blocks
in door frame wireway.
New terminal block located in
RH door frame wireway.
10
11 12
13
14 16 17 20
21
22
24 25
26
10
11
12
13
14 16
17
20
21
22
24 25
26
10
11 12
13
14 16 17 20
21
22
24 25
26
Lights (120) Fans & AS (Ntrl)
Lights (Ntrl)
Front of Case
(Three door Frame)
End Case
(Two door Frame)
Rear of Case
(Three door Frame)
Gas Defrost Sequence - Low Temperature
1. Defrost vapor enters evaporator causing a rise in temperature. At about 35°F the Control Relay Thermostat
(5)
closes the Fan Relay Coil
(7)
and Control Relay Coil
(6)
circuit. The Coil opens the Fan, Door Heater,
and Frame Heater circuits, while energizing the Drain Pan Heater
(9)
.
2.
If the Drain Pan Heater
(9)
raises internal air temperature above 90°F, the Heater Limit Thermostat
(4)
will open.
3.
When the defrost timer ends a defrost period, the evaporator temperature will start to fall. At about 20°F, the Control
Relay Thermostat will open, de-energizing the Control Relay Coil and Fan Relay Coil
(7).
Control and Fan Relay’s
will open the Drain Pan Heater circuits, and will close the Fan, Door Heater, and Frame Heater circuits.
LifeLine Premier
RLNIE
With INNOVATOR Doors
Frozen Food & Ice Cream
Page 14
Wiring Diagrams shown are for the RLNIE Island merchandisers with 60 in. EcoShine or EcoShine Energy Plus LEDs.
LifeLine Premier
RLNIE with Innovator Doors
Technical Data Sheet
14 of 15
U.S. & Canada 1-800-922-1919 • Mexico 1-800-522-1900
Optional Lighting 24VDC
Power Supply
EcoShine LED Lighting Circuits
LifeLine Premier
RLNIE
With INNOVATOR Doors
Frozen Food & Ice Cream
WIREWAY
RED
BLUE
RED
RED
BLACK
BLACK
RED
BLACK
BLACK
INPUT
OUTPUT
BLACK
WHITE
LIGHT
SWITCH
3 DOOR RH SIDE COMPARTMENT LED LIGHT WIRING DIAGRAM
RED
RED
RED
BLACK
BLACK
TERMINAL BLOCK
BLACK
20
17
WHITE
BLACK
BLACK
BLACK
11
12
12
13 13
WIREWAY
20
17
RED
BLUE
RED
BLACK
BLACK
WHITE
TERMINAL BLOCK
INPUT
OUTPUT
BLACK
BLACK
WHITE
LIGHT
SWITCH
2 DOOR END COMPARTMENT
LED LIGHT WIRING DIAGRAM
11
RED
BLACK
12
WIREWAY
RED
BLUE
RED
RED
BLACK
BLACK
RED
BLACK
BLACK
INPUT
OUTPUT
BLACK
WHITE
LIGHT
SWITCH
3 DOOR LH SIDE COMPARTMENT LED LIGHT WIRING DIAGRAM
RED
RED
RED
BLACK
BLACK
TERMINAL BLOCK
BLACK
20
17
WHITE
BLACK
BLACK
BLACK
11
12
12
13
13
Page 15
Light Switch
Red
Blue
Red
Blue
Red
Blue
Red
Blue
Black
White
White
Black
White
Black
White
Orange
Orange
Ter min al
Block
Black 120 VAC from Wireway
17
20
Power Supply 24VDC
Facade LED 1Facade LED 2Facade LED 3
Input
Output
11
14
14
14
Side
Light Switch
Black
White
Red
Blue
Blue
Black
Black 120 VAC from Wireway
White
Orange
White
Black
White
Orange
Enclosure or
Wireway
Ter min al
Block
17
20
Facade LED 1Facade LED 2
Input
Output
Power Supply 24VDC
Red Red
Blue
External Facade LED Wiring
11
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
THESE ARE MARKER COLORS (WIRE MAY VARY.)
R = Red P = Purple 2P = Purple (2 Bands)
DB = Dark Blue BK = Black
BR =Brown Y =Yellow OR = Orange W = White
14
14
End
Light Switch
Red
Blue
Red
Blue
Red
Blue
Red
Blue
Black
White
White
Black
White
Black
White
Orange
Orange
Ter min al
Block
Black 120 VAC from Wireway
17
20
Power Supply 24VDC
Facade LED 1Facade LED 2Facade LED 3
Input
Output
11
14
14
14
Side
= 120V POWER = 120V NEUTRAL = FIELD GROUND
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
= CASE GROUND
15 of 15P/N 0510312_B
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM