Hussmann Lifeline RLNI Specifications

Page 1
®
LifeLine Premier
RLNI
with
INNOVATOR
Doors
Technical Data Sheet
P/N 0510309_B
NSF
®
Certified
May 2010
We reserve the right to change or revise specifications and product design in con­nection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
OPTIONS SHOWN:
• Lighted Facades
• Facade Arch
Warning:
Terminal block NOT for
case-to-case
wire connection!
Item Part # Description Wiring Item #
F
AN ASSEMBLIES, AND THERMOSTATS
A. 12W Standard Fan Assembly (1)
MO.4410103 Fan Motor, Evaporator FB.4780446 Fan Blade 12W Optional Energy Efficient Fan Assembly (1) MO.4410546 Fan Motor, Evaporator FB.4780446 Fan Blade
B. CT.4440726 Standard Non-adjustable Defrost (2)
Thermostat C. Optional Adjustable Refrigeration Thermostat (3) D. CT.4440261 Defrost Limit Thermostat (4)
E. CT.4481296 Relay Control Thermostat or (5)
Fan and Anti-sweat Heater Thermostat
R
ELAYS
F. RL.4480238 Anti-Sweat Control Relay (120V) (6)
G. Fan Control Relay (7)
RL.4480237 (208V) Electrical Defrost RL.4480238 (120V) KoolGas Defrost
HEATERS
H. Electric Defrost Heaters – Front (208V) (8)
HE.4850346 (1) 2 Door Models HE.4850337 (1) 3 Door Models HE.4850347 (1) 4 Door Models HE.4850323 (1) 5 Door Models Electric Defrost Heaters — Rear (208V) (8) HE.4850358 (1) 2 Door Models HE.4850359 (1) 3 Door Models HE.4850360 (1) 4 Door Models HE.4850361 (1) 5 Door Models
I. Drain Pan Heater — Electric & KoolGas (120V) (9)
HE.4850239 (1) 2 Door Models HE.4850240 (1) 3 Door Models HE.4850241 (1) 4 Door Models HE.4850242 (1) 5 Door Models
Item Part # (Qty) Description Wiring Item #
LED F
IXTURES AND POWER SUPPLY
J. EP.4481668 Power Supply (10)
K. Door Lamp, LED
ECOSHINE
BU.4441328 3500K Standard Angle 60-in. Center (11) BU.4441330 4100K Standard Angle 60-in. Center (11) BU.4441329 3500K Standard Angle 60-in. End (12) BU.4441331 4100K Standard Angle 60-in. End (12) BU.4441644 3500K Wide Angle 60-in. Center (11) BU.4441646 4100K Wide Angle 60-in. Center (11) BU.4441645 3500K Wide Angle 60-in. End (12) BU.4441647 4100K Wide Angle 60-in. End (12)
ECOSHINE EP (ENERGY PLUS)
BU.4441394 3500K Standard Angle 60-in. Center (11) BU.4441396 4100K Standard Angle 60-in. Center (11) BU.4441395 3500K Standard Angle 60-in. End (12) BU.4441397 4100K Standard Angle 60-in. End (12) BU.4441648 3500K Wide Angle 60-in. Center (11) BU.4441650 4100K Wide Angle 60-in. Center (11) BU.4441649 3500K Wide Angle 60-in. End (12) BU.4441651 4100K Wide Angle 60-in. End (12)
L. Facade Lamp, LED (13)
BU.4441411 2900K 29.5 In. Length BU.4441412 2900K 30.5 In. Length
P/N0510309B
©2010 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
Refer to INNOVATOR REACH-IN GLASS DOOR INSTALLATION AND SERVICE manual, P/N 0425683,
for Innovator and Innovator II door and frame replacement parts.
NOTE: Revision B updates pages 1, 3, 4, 5 and 7. Changes are underlined, circled or marked with a vertical line in the margin.
L
Serial Plate
K
E
A
H
D
J
I
C
G
F
B
Page 2
LifeLine Premier
RLNI with Innovator Doors
Technical Data Sheet
2 of 11
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
Reach-In
2, 3, 4 & 5 Door
Engineering
Plan Views
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/4 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
7
/8
LifeLine Premier
RLNI
Plan View
09-2009
Base 5-door merchandiser is shown above, without Partitions or Ends. Dry Goods cabinets and Bump Out
not available on island models. Refer to chart on Page 3 for detailed dimensional information on options.
Dimensions shown as inches and (mm).
Clearance for Door Swing
B
D
7
(178)
Rear Relay & Terminal Block Location
Refrigeration Outlet
Electrical Wireway
C
Skid/ External Base
A
Waste Outlet
48
(1219)
Splashguard
Electrical Wireway
6
(152)
Bottom Front Support
Refrigeration Outlet
1
26
/2
(673)
60 5/8
(1541)
63 1/4
(1607)
70 1/8
(1780)
D
72 3/8
(1838)
125 3/8
(3185)
4
(102)
(see note *)
13/4
(44)
Water Seal
Front Relay & Terminal Block Location
(see note **)
(see note *)
13/4
(44)
B
26
(673)
1
/2
C
Clearance for Door Swing
Front
5-Door Shown
Page 3
3 of 11P/N 0510309_B
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
LifeLine Premier
RLNI
With INNOVATOR Doors
Frozen Food & Ice Cream
Plan View Dimensions for
LifeLine Premier
Options
2 Dr 3 Dr 4 Dr 5 Dr
General
(A) Merchandiser Length 62 (1575) 92
1
/
2 (2350) 122
7
/
8 (3121) 153
3
/
8 (3896)
Maximum O/S dimension of merchandiser back to front *** 72
3
/
8 (1838) 72
3
/
8 (1838) 72
3
/
8 (1838) 72
3
/
8 (1838)
***
Includes bumper. Add 53 in. (1346 mm) for door swing.
Width of Skid rail 3 3/
4 (95) 3
3
/
4 (95) 3
3
/
4 (95) 3
3
/
4 (95)
Width of Bottom Front Support 6 (152) 6 (152) 6 (152) 6 (152)
Stub-up area between front support and splashguard 3
1
/
8 (79) 3
1
/
8 (79) 3
1
/
8 (79) 3
1
/
8 (79)
Electrical Service
(B) RH end of merchandiser to the center of nearest knockout 4 (102) 4 (102) 4 (102) 4 (102)
RH end of merchandiser to the center of LH knockout 58 (1473) 88
1
/
2 (2248) 118
7
/
8 (3019) 149
3
/
8 (3794)
* NOTE: Electrical Field Wiring Connection Point is at terminal.
Waste Outlet
(C) Right end of merchandiser to center of waste outlet 23 7/
8 (606) 54
1
/
4 (1378) 46
1
/
4 (1175) 76
5
/
8 (1946)
Water Seal
Edge of water seal to center of waste outlet 13 (330) 13 (330) 13 (330) 13 (330)
Schedule 40 PVC drip pipe 1
1
/
4 (32) 1
1
/
4 (32) 1
1
/
4 (32) 1
1
/
4 (32)
** NOTE: Field installed water seal outlets, tees, and connectors are shipped with merchandiser.
Refrigeration Outlet
(D) RH end of merchandiser to center of RH refrigeration outlet 5 3/8 (136) 5 3/8 (136) 5 3/8 (136) 5 3/8 (136)
Back O/S of merchandiser to center of refrigeration outlet 60 5/8 (1541) 60 5/8 (1541) 60 5/8 (1541) 60 5/8 (1541)
Outside bottom front supports from end of merchandiser 7 (178) 7 (178) 7 (178) 7 (178)
Distance between centerlines of Center bottom front support 48 (1219) 48 (1219) 48 (1219) 48 (1219)
Distance between Center and Outside supports will vary
Page 4
LifeLine Premier
RLNI with Innovator Doors
Technical Data Sheet
4 of 11
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
LifeLine Premier
RLNI
With INNOVATOR Doors
Frozen Food & Ice Cream
Facade Options in Cross Section
12 1/8
(308)
18 1/8
(460)
Facade (Installed Position)
Facade (Shipping Position)
12 in. Straight Facade
Facade (Installed Position)
Facade (Shipping Position)
18 in. Straight Facade
Facade (Installed Position)
17 1/2
94 1/2
(2401)
Installed
(445)
87 1/2
(2222)
Shipped
12 in. Arch Facade
100 1/2
(2553)
Installed
87 1/2
(2222)
Shipped
23 1/2
(597)
Facade (Installed Position)
Facade (Shipping Position)
18 in. Arch Facade
Facade (Shipping Position)
99 7/8
(2537)
Installed
87 1/2
(2222)
Shipped
105 7/8
(2689)
Installed
87 1/2
(2222)
Shipped
Page 5
REFRIGERATION DATA
Note: This data is based on store temperature and humidity that does not exceed 75°F and 55% R.H.
FF IC
Discharge Air (°F) –5 –12
Evaporator(°F) –11 –19
Unit Sizing (°F) –14 –22
Btu/hr/door/side * FF IC
Parallel
1080 1144
Conventional
1200 1270
* Optional Energy Efficient Fan motors reduce refrigeration load by 109 Btu/hr/door/side.
DEFROST DATA
FF IC
Frequency (hr) 24 24
Defrost Water
(lb/Dr/side/day) 1.2 1.2
(± 15% based on case configuration and
product loading).
ELECTRIC FF IC
Temp Term (°F) 48° 48°
Failsafe (minutes) 45 45
GAS
Duration (minutes) 20 20
O
FFTIME Not Recommended
CONVENTIONAL CONTROLS
Low Pressure Backup Control
FF IC
CI/CO (Temp °F)** –18°/ –34° –26°/ –45°
Indoor Unit Only, Pressure Defrost
Termination (Temp °F)**
Not Recommended **Use a Temperature Pressure Chart to determine PSIG conversions.
Estimated Charge per Side ***
2Dr 1.8 lb 29 oz 0.8 kg
3Dr 2.7 lb 43 oz 1.2 kg
4Dr 3.6 lb 58 oz 1.6 kg
5Dr 4.6 lb 74 oz 2.1 kg
***This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately 0.5 lb (8 oz / 0.2 kg).
LifeLine Premier
RLNI
With INNOVATOR Doors
Frozen Food & Ice Cream
Facade (Installed Position)
23 1/2
(597)
18 in. Arch Facade
Shown
72 (1838)
70 (1778)
4
(121)
11
(298)
67
(1702) Frame
65 1/2
(1664)
Door
82 1/4
(2089)
13 1/8
(333)
Frame
6
1
/4
(159)
63 (1607)
60 (1540)
3 1/2
(89)
9
(232)
2 1/8
(54)
Facade (Installed Position)
23 1/2
(597)
87 1/2
(2222)
Shipped
105 7/8
(2689)
Installed
Facade (Shipping Position)
Dimensions shown as inches and (mm).
LifeLine Premier
Narrow Island Reach-in 2, 3,
4 and 5 Door Models
5 of 11P/N 0510309_B
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.
LifeLine
Premier
RLNI
See Page 4 for alternate facade heights.
Refrigeration data is PER SIDE.
Page 6
Electrical Data
2Dr 3Dr 4Dr 5Dr
Number of Fans—12W 2 3 4 5
Amperes Watts
Merchandiser 2Dr 3Dr 4Dr 5Dr 2Dr 3Dr 4Dr 5Dr
Evaporator Fan
120V 60Hz Standard 1.30 1.95 2.60 3.25 100 150 200 250
120V 50Hz Standard 1.50 2.25 3.00 3.75 114 171 228 285
220V 60Hz Export 0.66 0.99 1.32 1.65 100 150 200 250
220V 50Hz Export 0.76 1.14 1.52 1.90 114 171 228 285
120V 60Hz Energy Efficient 0.60 0.90 1.20 1.50 36 54 72 90
220V 60Hz Energy Efficient 0.30 0.45 0.60 0.75 36 54 72 90
Door Anti-sweat Heaters (on fan circuit)
120V 50/60Hz Standard 1.54 2.31 3.08 3.86 185 278 370 463
220V 50/60Hz Export 0.84 1.26 1.68 2.10 185 278 370 463
Frame Anti-sweat Heaters (on fan circuit)
120V 50/60Hz Standard 0.78 1.18 1.57 1.97 94 141 188 236
220V 50/60Hz Export 0.43 0.64 0.85 1.07 94 141 188 236
Minimum Circuit Ampacity
120V 60Hz Standard 3.82 5.64 7.45 9.28
120V 50Hz Standard 4.02 5.94 7.85 9.78
220V 60Hz Export 2.13 3.09 4.05 5.02
220V 50Hz Export 2.23 3.24 4.25 5.27
120V 60Hz Energy Efficient 3.12 4.59 6.05 7.53
220V 60Hz Energy Efficient 1.77 2.55 3.33 4.12
Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 220V 15 15 15 15
Defrost
Drain Heaters (120V) 0.63 1.25 2.00 2.50 75 150 240 300
(Export: 220V 50 hz) 0.39 0.76 1.22 1.53 84 168 269 336
208V 1Ø Electric Defrost 6.72 10.08 13.46 16.82 1400 2100 2800 3500
(Export: 220V 50 hz) 7.11 10.66 14.24 17.79 1564 2345 3133 3914
Standard Vertical Lighting* 2Dr 3Dr 4Dr 5Dr 2Dr 3Dr 4Dr 5Dr
Hussmann EcoShine™ (24VDC) 0.45 0.68 0.90 1.13 54 81 108 135
Optional LED Lighting (24VDC)
Facade Lamps 0.79 1.17 1.54 1.92 19 28 37 46
* Innovator or Innovator II.
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
LifeLine Premier
RLNI with Innovator Doors
Technical Data Sheet
6 of 11
LifeLine Premier
RLNI
With
INNOVATOR Doors
Frozen Food & Ice Cream
Hussmann recommends against frame heater cycling with
Innovator
doors to prevent door seals from freezing to the
frames and tearing.
ELECTRICAL DATA IS PER SIDE — TWO CIRCUITS REQUIRED PER CASE.
Page 7
Product Data
Recommended Usable Cube 1(Cu Ft/Dr) 22.80 ft3 /Dr (0.65 m3 /Dr) AHRI Total Display Area 2(Sq Ft/Dr) 13.31 ft2/Dr (1.24 m2 /Dr) Shelf Area 3(Sq Ft/Dr) 28.50 ft2/Dr (2.65 m2 /Dr)
1
AHRI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume/Unit of Length, ft3/ft [m3/m]
2
Computed using AHRI 1200 standard methodology: Total Display Area, ft2[m2]/Unit of Length, ft [m]
3
Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann Product Reference Guide. The standard shelf complement for this model is (5) rows of 22-inch shelves.
7 of 11P/N 0510309_B
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
LifeLine Premier
RLNI
With INNOVATOR Doors
Frozen Food & Ice Cream
ESTIMATED SHIPPING WEIGHT
4
2 Dr 3 Dr 4 Dr 5 Dr Solid End (each)
Standard LifeLine Premier Merchandiser (12-Inch Facade, no Arch)
lb (kg) 1204 (546) 2320 (1052) 3094 (1403) 3868 (1454) 110 (50)
Standard LifeLine Premier Merchandiser (18-Inch Facade, no Arch)
lb (kg) 1244 (564) 2380 (1080) 3174 (1440) 3968 (1800) 110 (50)
Add 10 lb (5 kg) for Arch each side
4
Actual weights will vary according to optional kits included.
PRODUCT DATA IS PER SIDE.
Page 8
LifeLine Premier
RLNI with Innovator Doors
Technical Data Sheet
8 of 11
A.S. Relay
Coil
BR
Evaporator Fans
1
Fan Relay
F
COM
N.O.
Rod Heater (Drain)
9
Y
Y
N.C.
7
7
1
3
W
Relay Control
c
25
Fan Relay
F
5
6
COM
N.C.
6
A.S. Relay
A.S.
24
Door A.S. Heaters
Frame A.S. Heaters
21
22
2P
P
2P
P
12
11
10
120V POWER
16
13
14
26
C.O.R.
NEUTRAL
BK
BK
BK
BK
OR
120V POWER
OR
NEUTRAL
17
20
Switch
Evaporator Fan
Relay Coil
1
3
Rear Defrost Heater
R
R
C
8
R
R
Front Defrost Heater
R
5
4
7
R
N.C.
7
8
8
Defrost Limit
208V
208V
1
2
3
4
6
O.O.R.
Defrost Termination
Thermostat
Refrigeration
Thermostat
(Optional)
Pink
2
3
}
To Condensing Unit
Dark Blue
DB
C.O.R.
2
Defrost Termination
Thermostat
FIELD WIRED
DB
Terminal Blocks in Raceway
Low Temperature with
Electric Defrost
202122
26
17
1234
56 7
81011 1413 16
LIGHTS
(120V)
DEFROST HEATERS
(208V)
CAUTION: When multiplexing merchandisers equipped with defrost heaters, if branch circuit overcurrent protection is larger than the
circuit load, then additional supplemental overcurrent protection may be required per NEC Articles 210 and 240.
Low Temperature
24 2512
FANS & A.S.
(120V)
LIGHTS
(Neutral)
FANS & A.S. (Neutral)
Permanent Internal
Jumpers
R P
W
BRORRRR RR P
2P
OR 2P Y
Removable External
Jumpers
Refer to Innovator Reach-In
Glass Door, Installation and Service manual, P/N 0425683,
for Innovator door and frame replacement parts.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
THESE ARE MARKER COLORS (WIRE MAY VARY.)
R = Red P = Purple 2P = Purple (2 Bands) DB = Dark Blue BK = Black
LB = Light Blue Pink = Pink BR =Brown Y =Yellow OR = Orange W = White
BK
BK
BK
BK
BK
BK
BK
BK
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
Electric Defrost Sequence - Low Temperature
1. Power from the defrost contactor energizes Defrost Heaters and 208V Evaporator Fan Relay Coil (7). Relay Contacts open the fan circuit and energizes the Drain Pan Heater.
2. If the Defrost Heater raises internal air temperature above 90°F, the Defrost Limit Thermostat (4) will open.
3. Temperature rise of the evaporator closes the Relay Control Thermostat (5) at about 35°F, energizing 120V A.S. Relay Coil (6). This relay’s contacts open the Frame and Door Heater Circuits.
4. When Defrost Termination Thermostat ends defrost period, the defrost contactor opens the Defrost Heater and Evaporator Fan Relay Coil Circuits. The Drain Pan Heater goes off and fans are on.
5. Temperature fall of the evaporator opens the Relay Control Thermostat (5) at about 20°F, de-energizing 120V A.S. Relay Coil (6). A.S. Relay Contacts close the Frame and Door Heater Circuits.
Fan and Heater Circuits — Electric Defrost (standard)
Low Temperature
Wiring Diagram is per side — two circuits required per case.
Wiring Diagram is per side — two circuits required per case.
Page 9
9 of 11P/N 0510309_B
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Gas Defrost Sequence - Low Temperature
1. Defrost vapor enters evaporator causing a rise in temperature. At about 35°F the Control Relay Thermostat (5) closes the A.S. Relay Coil
(6) and Fan Relay Coil (7) circuit. The Relay opens the Fan, Door Heater, and Frame Heater
circuits, while energizing the Drain Pan Heater (9).
2. If the Drain Pan Heater (9) raises internal air temperature above 90°F, the Heater Limit Thermostat (4) will open.
3. When the defrost timer ends a defrost period, the evaporator temperature will start to fall. At about 20°F, the Relay
Control Thermostat will open, de-energizing the A.S. Relay Coil (6) and Fan Relay Coil (7). The A.S. and Fan Relays will open the Drain Pan Heater circuits, and will close the Fan, Door Heater, and Frame Heater circuits.
Fan and Heater Circuits — Gas Defrost (optional)
Low Temperature
Wiring Diagram is per side — two circuits required per case.
Wiring Diagram is per side — two circuits required per case.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
R = Red P = Purple 2P = Purple (2 Bands) DB = Dark Blue BK = Black
LB = Light Blue Pink = Pink BR =Brown Y =Yellow OR = Orange W = White
THESE ARE MARKER COLORS (WIRE MAY VARY.)
NEUTRAL
120V POWER
BK
14
16
13
BK
BK
COM
Fan Relay
Fan Relay
A.S. Relay
COM
F
F
A.S.
N.C.
N.O.
N.C.
7
7
Defrost Limit
Y
Relay Control
6
BK
Evaporator Fans
4
O.O.R.
5
C.O.R.
10
11
12
1
Rod Heater (Drain)
A.S. Relay
3
Fan Relay
Frame A.S. Heaters
P
Door A.S. Heaters
2P
Coil
c
c
Coil
BR
26
Refer to Innovator Reach-In
9
Y
Glass Door, Installation and
25
Service manual, P/N 0425683, for Innovator door and frame replacement parts.
6
1
W
24
7
P
22
2P
21
NEUTRAL
OR
20
24 2512
26
FANS & A.S. (Neutral)
Refrigeration
Thermostat
(Optional)
Pink
}
3
To Condensing Unit
Low Temperature with
Gas Defrost
Removable External
Jumpers
120V POWER
OR
17
Terminal Blocks in Raceway
BK BK BK BK
10 11 1413 16
FANS & A.S.
(120V)
Switch
20
17
21
LIGHTS
(120V)
LIGHTS
(Neutral)
Permanent Internal
Jumpers
PW BRORP2P OR2P Y
22
Page 10
LifeLine Premier
RLNI with Innovator Doors
Technical Data Sheet
10 of 11
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
Standard Vertical Lighting
Hussmann EcoShine
LED Fixtures
Wiring Diagram is per side — two circuits required per case.
Wiring Diagram is per side — two circuits required per case.
SWITCH
LIGHT
BLACK
WHITE
BLACK
12
RED
BLACK
INPUT
WIREWAY
OUTPUT
RED
BLUE
RED
RED
BLACK
BLACK
10
1211
RED
TERMINAL BLOCK
20
17
WHITE
BLACK
BLACK
2 DOOR LED LIGHT WIRING DIAGRAM
SWITCH
LIGHT
BLACK
INPUT
WHITE
12
RED
BLACK
RED
OUTPUT
10
BLUE
RED
11
RED
BLACK
BLACK
RED
11
RED
BLACK
BLACK
12
RED
TERMINAL BLOCK
17
20
WHITE
BLACK
WIREWAY
BLACK
BLACK
3 DOOR LED LIGHT WIRING DIAGRAM
SWITCH
LIGHT
12
RED
BLACK
BLACK
INPUT
WHITE
BLACK
RED
11
RED
BLACK
BLACK
RED
BLUE
OUTPUT
RED
11
RED
BLACK
BLACK
10
RED
11
RED
BLACK
BLACK
12
RED
TERMINAL BLOCK
17
20
WHITE
BLACK
BLACK
WIREWAY
4 DOOR LED LIGHT WIRING DIAGRAM
SWITCH
LIGHT
RED
12
BLACK
BLACK
WHITE
RED
11
RED
BLACK
BLACK
11
RED
RED
BLACK
BLACK
RED
BLUE
INPUT
OUTPUT
10
RED
11
RED
BLACK
BLACK
BLACK
INPUT
WHITE
11
RED
RED
BLACK
BLACK
RED
OUTPUT
10
BLUE
TERMINAL BLOCK
12
RED
BLACK
WIREWAY
17 20
BLACK
BLACK
BLACK
5 DOOR LED LIGHT WIRING DIAGRAM
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
= 120V POWER = 120V NEUTRAL
= FIELD GROUND
= CASE GROUND
Page 11
11 of 11P/N 0510309_B
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
LifeLine Premier
RLNI
With INNOVATOR Doors
Frozen Food & Ice Cream
Wiring Diagram is per side — two circuits required per case.
Wiring Diagram is per side — two circuits required per case.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
R = Red P = Purple 2P = Purple (2 Bands)
DB = Dark Blue B = Black
BR =Brown Y =Yellow OR = Orange W = White
THESE ARE MARKER COLORS (WIRE MAY VARY.)
External Facade LED Wiring
White
Orange
Orange
Black
White
Black
Black 120 VAC from Wireway
White
Enclosure or
Wireway
Light Switch
17
20
Ter min al
Block
Side
White
Black
Power Supply 24VDC
Input
13
10
Red
Blue
Output
Blue
13
Red
Red
Blue
13
Facade LED 1Facade LED 2Facade LED 3
Red
Blue
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
= 120V POWER = 120V NEUTRAL
= FIELD GROUND
= CASE GROUND
Loading...