Electrical Data
2Dr 3Dr 4Dr 5Dr
Number of Fans—12W 2 3 4 5
Amperes Watts
Merchandiser 2Dr 3Dr 4Dr 5Dr 2Dr 3Dr 4Dr 5Dr
Evaporator Fan
120V 60Hz Standard 1.30 1.95 2.60 3.25 100 150 200 250
120V 50Hz Standard 1.50 2.25 3.00 3.75 114 171 228 285
220V 60Hz Export 0.66 0.99 1.32 1.65 100 150 200 250
220V 50Hz Export 0.76 1.14 1.52 1.90 114 171 228 285
120V 60Hz Energy Efficient 0.60 0.90 1.20 1.50 36 54 72 90
220V 60Hz Energy Efficient 0.30 0.45 0.60 0.75 36 54 72 90
Door Anti-sweat Heaters (on fan circuit)
120V 50/60Hz Standard 1.54 2.31 3.08 3.86 185 278 370 463
220V 50/60Hz Export 0.84 1.26 1.68 2.10 185 278 370 463
Frame Anti-sweat Heaters (on fan circuit)
120V 50/60Hz Standard 0.78 1.18 1.57 1.97 94 141 188 236
220V 50/60Hz Export 0.43 0.64 0.85 1.07 94 141 188 236
Minimum Circuit Ampacity
120V 60Hz Standard 3.82 5.64 7.45 9.28
120V 50Hz Standard 4.02 5.94 7.85 9.78
220V 60Hz Export 2.13 3.09 4.05 5.02
220V 50Hz Export 2.23 3.24 4.25 5.27
120V 60Hz Energy Efficient 3.12 4.59 6.05 7.53
220V 60Hz Energy Efficient 1.77 2.55 3.33 4.12
Maximum Over Current Protection 120V 20 20 20 20
Maximum Over Current Protection 220V 15 15 15 15
Defrost
Drain Heaters (120V) 0.63 1.25 2.00 2.50 75 150 240 300
(Export: 220V 50 hz) 0.39 0.76 1.22 1.53 84 168 269 336
208V 1Ø Electric Defrost 6.72 10.08 13.46 16.82 1400 2100 2800 3500
(Export: 220V 50 hz) 7.11 10.66 14.24 17.79 1564 2345 3133 3914
Standard Vertical Lighting* 2Dr 3Dr 4Dr 5Dr 2Dr 3Dr 4Dr 5Dr
Hussmann EcoShine™ (24VDC) 0.45 0.68 0.90 1.13 54 81 108 135
Optional LED Lighting (24VDC)
Facade Lamps 0.79 1.17 1.54 1.92 19 28 37 46
* Innovator or Innovator II.
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
LifeLine Premier
RLNI with Innovator Doors
Technical Data Sheet
6 of 11
LifeLine Premier
RLNI
With
INNOVATOR Doors
Frozen Food & Ice Cream
Hussmann recommends against frame heater cycling with
Innovator
doors to prevent door seals from freezing to the
frames and tearing.
ELECTRICAL DATA IS PER SIDE — TWO CIRCUITS REQUIRED PER CASE.