Hussmann Lifeline DGRL Specifications

Page 1
®
F
G
K
A
J
M
C
J
L
H
E
D
N
B
LifeLine Premier Stand
Alone Dry Goods Kit
for RL with
INNOVATOR
Doors
P/N 0512405_A
NSF
®
Certified
October 2009
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
OPTIONS SHOWN:
• Lighted Facades
• Arch Facade
Warning:
Terminal block NOT for
case-to-case
wire connection!
Item Part # Description Wiring Item #
FAN ASSEMBLIES, AND THERMOSTATS
A. 12W Standard Fan Assembly (1)
MO.4410103 Fan Motor, Evaporator FB.4780446 Fan Blade 12W Optional Energy Efficient Fan Assembly (1) MO.4410546 Fan Motor, Evaporator FB.4780446 Fan Blade
B. CT.4440726 Standard Non-adjustable Defrost (2)
Thermostat C. Optional Adjustable Refrigeration Thermostat (3) D. CT.4440261 Defrost Limit Thermostat (4)
E. CT.4481296 Relay Control Thermostat or (5)
Fan and Anti-sweat Heater
Thermostat
RELAYS
F. RL.4480238 Anti-Sweat Control Relay (120V) (6)
G. RL.4480237 Fan Control Relay (208V) (7)
HEATERS
H. Electric Defrost Heaters – Front (208V) (8)
HE.4850346 (1) 2 Door Models HE.4850337 (1) 3 Door Models HE.4850347 (1) 4 Door Models Electric Defrost Heaters — Rear (208V) (8) HE.4850358 (1) 2 Door Models (HE.4850358) HE.4850359 (1) 3 Door Models (HE.4850359) HE.4850360 (1) 4 Door Models (HE.4850360)
Item Part # (Qty) Description Wiring Item #
HEATERS (CONTINUED)
I. Drain Pan Heater — Electric & KoolGas (120V) (9)
HE.4850239 (1) 2 Door Models HE.4850240 (1) 3 Door Models HE.4850241 (1) 4 Door Models
LED FIXTURES AND POWER SUPPLY
J. EP.4481668 Power Supply (10)
K. Door Lamp, LED
BU.4440875 3500K Center (11) BU.4440877 4100K Center (11) BU.4440876 3500K End (12) BU.4440878 4100K End (12)
L. Facade Lamp, LED (13)
BU.4441411 2900K 29.5 In. Length BU.4441412 2900K 30.5 In. Length
M. Dry Goods Lamp, LED (14)
BU.4441414 3500K
N. Side Dry Goods Lamp, LED (15)
BU.4482721 3500K
M. SH.4991645 KLU9600
Dry Goods Shelf, Lighted, Pearwood
N. SH.4992632 KKV2500
Side Dry Goods Shelf, Lighted, Pearwood
P/N0512405A
©2009 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
Refer to I
NNOVATOR REACH-IN GLASS DOOR
I
NSTALLATION AND SERVICE
manual, P/N 0425683, for Innovator and Innovator II door and frame replacement parts.
NOTE: Revision A is original issue.
Page 2
Front
4-Door Shown
6
(152)
41
5
/8
(1057)
Electrical Wireway
Bottom Front Support
48
(1219)
Relay & Terminal
Block Location
Skid/
External
Base
7
(178)
Splashguard
Waste Outlet
1
3
/4
(44)
4
(102)
1 3/4
(44)
B
34
5
/8
(879)
32
(813)
43
3
/4
(1111)
Door Swing
Clearance
26
1
/2
(674)
from Bumper
10 3/4
(273)
Shelf
Area
12 7/8
(327)
15
1
/4
(387)
Shelf
Area
4 in. (102 mm ) Minimum Air Gap from Merchandiser Insulated Panel to Wall or Flat Surface
Water Seal
(see note **)
(see note *)
A
(see note *)
B
Refrigeration
Outlet
Usable
Width
21 3/4
(552)
Shelf
Area
Shelf Area
Usable
Depth
13
(330)
Usable
Width
20
5
/8
(524)
19
1
/4
(489)
LifeLine Premier Stand Alone Dry Goods Kit
for RL
with
Innovator Doors Technical Data Sheet
2 of 11
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Reach-In
2, 3 & 4 Door
Engineering
Plan Views
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/4 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
7
/8
Plan View
LifeLine Premier
Stand Alone Dry Goods
Kit Applied to RL / RM
08-2009
Illustrated below is a 4-door merchandiser with Stand Alone Dry Goods cabinets.
Refer to chart on Page 3 for detailed dimensional information on options.
Dimensions shown as in. & (mm).
Page 3
3 of 11P/N 0510405_A
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
LifeLine Premier
Stand Alone Dry Goods Kit
RL With INNOVATOR Doors
Frozen Food & Ice Cream
Plan View Dimensions for
LifeLine Premier Stand Alone Dry Goods Kit
Options
Abbreviations: DG = Dry Goods section
General 2 Dr 3 Dr 4 Dr 5 Dr
(A) Merchandiser Length DG includes 4 ends and dry goods cabinets 92
1
/2 (2350) 123 (3124) 153 3/8 (3896) NA
Maximum O/S dimension of merchandiser back to front *** 43 3/
4 (1111) 43
3
/
4 (1111) 43
3
/
4 (1111) 43
3
/
4 (1111)
***
Includes bumper. Add 26 1/
2 in. (673 mm) for door swing.
Interior width of front dry goods cabinet 10 3/
4 (273) 10
3
/
4 (273) 10
3
/
4 (273) NA
Interior depth of front dry goods cabinet 12
7
/
8 (327) 12
7
/
8 (327) 12
7
/
8 (327) NA
Interior width of each side dry goods cabinet 22 (559) 22 (559) 22 (559) NA
Interior depth of each side dry goods cabinet 10
3
/
4 (273) 10
3
/
4 (273) 10
3
/
4 (273) NA
Back of merchandiser to rear of splashguard 39
7
/
8 (1013) 39
7
/
8 (1013) 39
7
/
8 (1013) 39
7
/
8 (1013)
Width of Skid rail 3
3
/4 (95) 3 3/4 (95) 3 3/4 (95) 3 3/4 (95)
Width of Bottom Front Support 6 (152) 6 (152) 6 (152) 6 (152)
Stub-up area between front support and splashguard 3 1/
8 (79) 3
1
/
8 (79) 3
1
/
8 (79) 3
1
/
8 (79)
Electrical Service
RH end of merchandiser to the center of nearest knockout DG 19
1
/
4 (489) 19
1
/
4 (489) 19
1
/
4 (489) NA
RH end of merchandiser to the center of LH knockout 58 (1473) 88
1
/2 (2248) 118 7/8 (3019) 149 3/8 (3794)
Back O/S of merchandiser to center of knockout 41 5/8 (1057) 41 5/8 (1057) 41 5/8 (1057) 41 5/8 (1057)
* NOTE: Electrical Field Wiring Connection Point is at terminal.
Waste Outlet
(B) Right end of merchandiser to center of waste outlet DG 39 (991) 69 1/
2 (1765) 61
1
/
2 (1562) NA
Back O/S of merchandiser to center of waste outlet 34
5
/8 (879) 34 5/8 (879) 34 5/8 (879) 34 5/8 (879)
Back O/S of merchandiser with bump-out to center of waste outlet † 46 5/
8 (1184) 46
5
/
8 (1184) 46
5
/
8 (1184) 46
5
/
8 (1184)
Water Seal
Edge of water seal to center of waste outlet 13 (330) 13 (330) 13 (330) 13 (330)
Schedule 40 PVC drip pipe 1
1
/4 (32) 1 1/4 (32) 1 1/4 (32) 1 1/4 (32)
** NOTE: Field installed water seal outlets, tees, and connectors are shipped with merchandiser.
Refrigeration Outlet
RH end of merchandiser to center of RH refrigeration outlet DG 20 5/8 (524) 20 5/8 (524) 20 5/8 (524) NA
Back O/S of merchandiser to center of refrigeration outlet 32 (813) 32 (813) 32 (813) 32 (813)
Back O/S of merchandiser with bump-out to center of refrigeration outlet 44 (1118) 44 (1118) 44 (1118) 44 (1118)
Outside bottom front supports from end of merchandiser 6 3/4 (170) 6 3/4 (170) 6 3/4 (170) 6 3/4 (170)
Outside bottom front supports from end of merchandiser DG 6 3/4 (170) 6 3/4 (170) 6 3/4 (170) NA
Center bottom front support from Centerline 24 (610) 24 (610) 24 (610) 24 (610)
Center bottom front support from Centerline DG 19 (483) 24 (610) 24 (610) NA
Distance between Center and Outside supports will vary
The Stand Alone
Dry
Goods
Cabinet
is not
offered
in the
5-door
length.
Page 4
Facade (Installed Position)
Facade (Shipping Position)
12 in. Arch Facade
17 1/2
(445)
87 1/2
(2222)
Shipped
99 7/8
(2537)
Installed
Facade (Installed Position)
Facade (Shipping Position)
12 in. Straight Facade
12 1/8
(308)
87 1/2
(2222)
Shipped
94 1/2
(2401)
Installed
Facade (Installed Position)
Facade (Shipping Position)
18 in. Straight Facade
18 1/8
(460)
87 1/2
(2222)
Shipped
100 1/2
(2553)
Installed
Facade (Installed Position)
Facade (Shipping Position)
18 in. Arch Facade
23 1/2
(597)
105 7/8
(2689)
Installed
87 1/2
(2222)
Shipped
LifeLine Premier Stand Alone Dry Goods Kit
for RL
with
Innovator Doors Technical Data Sheet
4 of 11
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Fixed Shelf
Adjustable
Shelves
Electrical Connection
for Shelf Lamps
Facade
Lamp
64 1/2
(1638)
Usable Height
12 3/4
(324)
Usable
Depth
43 3/4 (1111 )
77 3/4
(1975)
Fixed Shelf
Usable
Volume
Facade Options in Cross Section
End ProfilesDry Goods Cross-Section
LifeLine Premier Stand Alone Dry Goods Kit
RL With INNOVATOR Doors
Frozen Food & Ice Cream
Page 5
REFRIGERATION DATA
Note: This data is based on store temperature
and humidity that does not exceed 75°F and 55% R.H.
FF IC Discharge Air (°F) –5 –12 Evaporator (°F) –11 –19 Unit Sizing (°F) –14 –22
Btu/hr/Door*
Parallel
1200 1270
Conventional
1225 1300
*Optional Energy Efficient Fan motors reduce refrigeration load by 109 Btu/hr/Door.
DEFROST DATA
FF IC Frequency (hr) 24 24 Defrost Water (lb/Dr/day) 1.2 1.2
(± 15% based on merchandiser configuration
and product loading.)
E
LECTRIC
FF IC Temp Term (°F) 48° 48° Failsafe (minutes) 45 45
GAS
Duration (minutes) 20 20
O
FFTIME
Not Recommended
CONVENTIONAL CONTROLS
Low Pressure Backup Control
FF IC
CI/CO (Temp °F)** –18°/ –34° – 26°/ –45°
Indoor Unit Only, Pressure Defrost Termination (Temp °F)**
Not Recommended
**Use a Temperature Pressure Chart to determine PSIG conversions.
Estimated Charge (lb)***
2Dr 1.8 3Dr 2.7 4Dr 3.6
***This is an average for all refrigerant types. Actual refrigerant charge may vary by approx­imately half a pound.
2
(52)
13 1/8
(333)
Fan
Coil
62 1/2
(1588)
4
3
/4
(121)
22 Shelf
(559)
27
5
/8 (702)
3 7/8
(97)
Refrigeration Outlet
Electrical Field Wiring Connection is at Terminal
34 5/8 (879)
32 (813)
41 5/8 (1056)
6
1
/4
(159)
82 1/4
(2089)
2 5/8
(67)
41 (1041)
40 1/4 (1022)
83
(2108)
87 1/2
(2222)
Shipped
105 7/8
(2689)
Installed
Facade (Installed Position)
Facade (Shipping Position)
18 in. Arch Facade
Shown
23 1/2
(597)
43 3/4 (1111 )
67
(1702)
Frame
65 1/2
(1664)
Door
Dimensions shown as in. & (mm).
LifeLine Premier
Reach-in 2, 3 and 4 Door Models
5 of 11P/N 0510405_A
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.
LifeLine Premier
RL - RM
See Page 4 for alternate facade heights.
LifeLine Premier
Stand Alone Dry Goods Kit
RL With INNOVATOR Doors
Frozen Food & Ice Cream
Page 6
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Electrical Data
2Dr 3Dr 4Dr 5Dr
Number of Fans—12W 2 3 4 5
Amperes Watts
Merchandiser 2Dr 3Dr 4Dr 5Dr 2Dr 3Dr 4Dr 5Dr
Evaporator Fan
120V 60Hz Standard 1.30 1.95 2.60 3.25 100 150 200 250
120V 50Hz Standard 1.50 2.25 3.00 3.75 114 171 228 285
220V 60Hz Export 0.66 0.99 1.32 1.65 100 150 200 250
220V 50Hz Export 0.76 1.14 1.52 1.90 114 171 228 285
120V 60Hz Energy Efficient 0.60 0.90 1.20 1.50 36 54 72 90
220V 60Hz Energy Efficient 0.30 0.45 0.60 0.75 36 54 72 90
Door Anti-sweat Heaters (on fan circuit)
120V 50/60Hz Standard 1.54 2.31 3.08 3.86 185 278 370 463
220V 50/60Hz Export 0.84 1.26 1.68 2.10 185 278 370 463
Frame Anti-sweat Heaters (on fan circuit)
120V 50/60Hz Standard 0.78 1.18 1.57 1.97 94 141 188 236
220V 50/60Hz Export 0.43 0.64 0.85 1.07 94 141 188 236
Minimum Circuit Ampacity
120V 60Hz Standard 3.82 5.64 7.45 9.28
120V 50Hz Standard 4.02 5.94 7.85 9.78
220V 60Hz Export 2.13 3.09 4.05 5.02
220V 50Hz Export 2.23 3.24 4.25 5.27
120V 60Hz Energy Efficient 3.12 4.59 6.05 7.53
220V 60Hz Energy Efficient 1.77 2.55 3.33 4.12
Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 220V 15 15 15 15
Defrost
Drain Heaters (120V) 0.63 1.25 2.00 2.50 75 150 240 300
(Export: 220V 50 hz) 0.39 0.76 1.22 1.53 84 168 269 336
208V 1Ø Electric Defrost 6.72 10.08 13.46 16.82 1400 2100 2800 3500
(Export: 220V 50 hz) 7.11 10.66 14.24 17.79 1564 2345 3133 3914
Standard Vertical Lighting* 2Dr 3Dr 4Dr 5Dr 2Dr 3Dr 4Dr 5Dr
Hussmann EcoShine™ 0.45 0.68 0.90 1.13 54 81 108 135
Optional LED Lighting
Facade Lamps 0.18 0.28 0.36 1.92 22 33 43 46 Dry Goods Lamps 0.63 0.63 0.63 NA** 137 137 137 NA**
(11 per front, 11 per side — 44 total)
* Innovator or Innovator II.
** Dry Goods sections are not available on 5-Door models.
LifeLine Premier Stand Alone Dry Goods Kit
for RL
with
Innovator Doors Technical Data Sheet
6 of 11
Hussmann recommends against frame heater cycling with
Innovator
doors to prevent door
seals from freezing to the frames and tearing.
LifeLine Premier Stand Alone Dry Goods Kit
RL With INNOVATOR Doors
Frozen Food & Ice Cream
Page 7
7 of 11P/N 0510405_A
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Product Data (Refrigerated Area Only)
Recommended Usable Cube
1
(Cu Ft/Dr) 23.46 ft3 /Dr (0.66 m3 /Dr)
ARI Total Display Area
2
(Sq Ft/Dr) 13.31 ft2/Dr (1.24 m2 /Dr)
Shelf Area 3(Sq Ft/Dr) 29.32 ft2/Dr (2.72 m2 /Dr)
1
ARI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume/Unit of Length, ft3/ft [m3/m]
2
Computed using ARI 1200 standard methodology: Total Display Area, ft2[m2]/Unit of Length, ft [m]
3
Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann Product Reference Guide. The standard shelf complement for this model is (5) rows of 22-inch shelves.
Product Data (Dry Goods Area Only)
Front DG TOTAL Gross Usable Cube (2 DG per merchandiser) 10.77 ft3 / (0.30 m3 ) Side DG TOTAL Gross Usable Cube (2 DG per merchandiser) 10.77 ft3 / (0.30 m3 )
ESTIMATED SHIPPING WEIGHT
4
2 Dr 3 Dr 4 Dr 5 Dr Solid End (each)
LifeLine Premier Stand Alone Dry Goods Merchandiser (12-Inch Facade, no Arch)
lb (kg) 1507 (684) 1820 (826) 2135 (968) NA NA
LifeLine Premier Stand Alone Dry Goods Merchandiser (18-Inch Facade, no Arch)
lb (kg) 1537 (697) 1855 (841) 2175 (987) NA NA
Add 10 lb (5 kg) for Arch
4
Actual weights will vary according to optional kits included.
LifeLine Premier
Stand Alone Dry Goods Kit
RL With INNOVATOR Doors
Frozen Food & Ice Cream
Page 8
LifeLine Premier Stand Alone Dry Goods Kit
for RL
with
Innovator Doors Technical Data Sheet
8 of 11
A.S. Relay
Coil
BR
Evaporator Fans
1
Fan Relay
F
COM
N.O.
Rod Heater (Drain)
9
Y
Y
N.C.
7
7
1
3
W
B
Relay Control
c
25
Fan Relay
F
B
5
6
B
B
COM
N.C.
6
A.S. Relay
A.S.
24
Door A.S. Heaters
Frame A.S. Heaters
21
22
2P
P
2P
P
12
11
10
120V POWER
16
13
14
26
C.O.R.
NEUTRAL
OR
OR
NEUTRAL
17
20
Switch
Evaporator Fan
Relay Coil
1
3
Rear Defrost Heater
R
R
C
8
R
R
Front Defrost Heater
R
5
4
BB
7
R
N.C.
7
8
8
Defrost Limit
208V
208V
1
2
3
4
6
O.O.R.
Defrost Termination
Thermostat
Refrigeration
Thermostat
(Optional)
Pink
2
3
}
To Condensing Unit
Dark Blue
DB
C.O.R.
2
Defrost Termination
Thermostat
FIELD WIRED
DB
Terminal Blocks in Raceway
Low Temperature with
Electric Defrost
20
21
22
26
17
1234
56 7
81011 1413 16
LIGHTS
(120V)
DEFROST HEATERS
(208V)
CAUTION: When multiplexing merchandisers equipped with defrost heaters, if branch circuit overcurrent protection is larger than the
circuit load, then additional supplemental overcurrent protection may be required per NEC Articles 210 and 240.
Low Temperature
24 2512
FANS & A.S.
(120V)
LIGHTS
(Neutral)
FANS & A.S. (Neutral)
Permanent Internal
Jumpers
R P
W
BRORRRRBBRRBP2PBB ORB2PY
Removable External
Jumpers
Refer to Innovator Reach-In
Glass Door, Installation and Service manual, P/N 0425683,
for Innovator door and frame replacement parts.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
THESE ARE MARKER COLORS (WIRE MAY VARY.)
R = Red P = Purple 2P = Purple (2 Bands) DB = Dark Blue BL = Black
LB = Light Blue Pink = Pink BR =Brown Y =Yellow OR = Orange W = White
Electric Defrost Sequence - Low Temperature
1. Power from the defrost contactor energizes Defrost Heaters and 208V Evaporator Fan Relay Coil (7). Relay Contacts open the fan circuit and energizes the Drain Pan Heater.
2. If the Defrost Heater raises internal air temperature above 90°F, the Defrost Limit Thermostat (4) will open.
3. Temperature rise of the evaporator closes the Relay Control Thermostat (5) at about 35°F, energizing 120V A.S. Relay Coil (6). This relay’s contacts open the Frame and Door Heater Circuits.
4. When Defrost Termination Thermostat ends defrost period, the defrost contactor opens the Defrost Heater and Evaporator Fan Relay Coil Circuits. The Drain Pan Heater goes off and fans are on.
5. Temperature fall of the evaporator opens the Relay Control Thermostat (5) at about 20°F, de-energizing 120V A.S. Relay Coil (6). A.S. Relay Contacts close the Frame and Door Heater Circuits.
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Page 9
9 of 11P/N 0510405_A
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Permanent Internal
Jumpers
A.S. Relay
Coil
BR
Evaporator Fans
1
Fan Relay
F
COM
N.O.
Rod Heater (Drain)
9
Y
Y
N.C.
7
7
1
3
W
B
Relay Control
c
25
Fan Relay
F
B
5
6
B
B
COM
N.C.
6
A.S. Relay
A.S.
24
Door A.S. Heaters
Frame A.S. Heaters
22
2P
2P
P
12
10
120V POWER
13
26
C.O.R.
P
OR
120V POWER
OR
NEUTRAL
17
20
Terminal Blocks in Raceway
Low Temperature with
Gas Defrost
20
21
22
26
17
10 11 1413 16
LIGHTS
(120V)
Refrigeration
Thermostat
(Optional)
Pink
3
}
To Condensing Unit
24 2512
FANS & A.S.
(120V)
LIGHTS
(Neutral)
FANS & A.S. (Neutral)
P
W
BRORBP2PBB ORB2PY
Removable External
Jumpers
Low Temperature
16
7
Fan Relay
Coil
11
c
Defrost Limit
4
O.O.R.
14
21
NEUTRAL
Refer to Innovator Reach-In Glass Door, Installation and Service manual, P/N 0425683,
for Innovator door and frame replacement parts.
Switch
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
THESE ARE MARKER COLORS (WIRE MAY VARY.)
R = Red P = Purple 2P = Purple (2 Bands) DB = Dark Blue BL = Black
LB = Light Blue Pink = Pink BR =Brown Y =Yellow OR = Orange W = White
Gas Defrost Sequence - Low Temperature
1. Defrost vapor enters evaporator causing a rise in temperature. At about 35°F the Control Relay Thermostat
(5)
closes the Fan Relay Coil (7) and Control Relay Coil (6) circuit. The Coil opens the Fan, Door Heater, and Frame Heater circuits, while energizing the Drain Pan Heater
(9).
2. If the Drain Pan Heater (9) raises internal air temperature above 90°F, the Heater Limit Thermostat (4) will open.
3. When the defrost timer ends a defrost period, the evaporator temperature will start to fall. At about 20°F, the Control
Relay Thermostat will open, de-energizing the Control Relay Coil and Fan Relay Coil (7). Control and Fan Relay’s will open the Drain Pan Heater circuits, and will close the Fan, Door Heater, and Frame Heater circuits.
Page 10
LifeLine Premier Stand Alone Dry Goods Kit
for RL
with
Innovator Doors Technical Data Sheet
10 of 11
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
WIREWAY
RED
BLACK
RED
BLACK
20
17
RED
BLUE
RED
RED
BLACK
BLACK
BLACK
WHITE
TERMINAL BLOCK
INPUT
OUTPUT
BLACK
BLACK
WHITE
LIGHT
SWITCH
2 DOOR LED LIGHT WIRING DIAGRAM
10
12 1211
WIREWAY
RED
BLUE
RED
RED
BLACK
BLACK
RED
BLACK
BLACK
INPUT
OUTPUT
BLACK
WHITE
LIGHT
SWITCH
3 DOOR LED LIGHT WIRING DIAGRAM
RED
RED
RED
BLACK
BLACK
TERMINAL BLOCK
20
17
WHITE
BLACK
BLACK
12
12
10
11
11
WIREWAY
RED
BLUE
RED
RED
BLACK
BLACK
RED
BLACK
BLACK
INPUT
OUTPUT
BLACK
WHITE
LIGHT
SWITCH
4 DOOR LED LIGHT WIRING DIAGRAM
RED
RED
RED
BLACK
BLACK
TERMINAL BLOCK
20
17
RED
BLACK
RED
BLACK
BLACK
WHITE
BLACK
10
12
12
11
11
11
WIREWAY
RED
BLUE
RED
RED
BLACK
BLACK
RED
BLACK
BLACK
INPUT
OUTPUT
BLACK
WHITE
LIGHT
SWITCH
5 DOOR LED LIGHT WIRING DIAGRAM
RED
RED
RED
BLACK
BLACK
TERMINAL BLOCK
RED
BLUE
INPUT
OUTPUT
BLACK
WHITE
RED
BLACK
RED
BLACK
BLACK
RED
RED
BLACK
BLACK
BLACK
17 20
BLACK
10
12
10
12
11
11
11 11
= 120V POWER = 120V NEUTRAL = FIELD GROUND
= CASE GROUND
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
Standard Vertical Lighting
Hussmann EcoShine
LED Fixtures
Page 11
11 of 11P/N 0510405_A
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Red
Red
Red
Red
Red
Blue
Blue
Blue
Blue
Blue
Blue
Blue
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Blue
Blue
Blue
Blue
Blue
Blue
Blue
Blue
Blue
Blue
Blue
Blue
Blue
Red
Red
Red
Red
Red
Red
Red
Blue
Blue
Red
Red
RedBlue
Red
Blue
RedBlue
RedBlue
RedBlue
Red
Blue
Red
Blue
RedBlue
Blue
Red
Blue
Blue
Blue
Blue
Blue
Blue
Blue
Blue
Blue
Blue
Red
Black 120 VAC
from Wireway
Black
White
Enclosure or Wireway
Red
Blue
Red
Blue
Black
White
Black
White
Red
Blue
Red
Blue
Red
Blue
Blue
Red
Blue
Red
Blue
Red
Red
Blue
Red
Blue
Red
Blue
Red
Blue
Red
Blue
Red
Blue
Red
Blue
Red
Blue
Black
White
Black
White
Light Switch
Facade
LED 5
Facade
LED 4
Facade
LED 3
Facade
LED 2
Facade
LED 1
13 13 13 13 13
Orange
Orange
Terminal Block
17 20
Light Switch
White
Power Supply
10
Input
Output
Power Supply
10
Input
Output
Power Supply
10
Input
Output
Pilaster / Shelf Standard
Pilaster / Shelf Standard
Pilaster / Shelf Standard
Pilaster / Shelf Standard
Pilaster / Shelf Standard
Pilaster / Shelf Standard
Pilaster / Shelf Standard
Pilaster / Shelf Standard
Red
Blue
Red
Blue
15 14 14 15
Shelf Lamps (up to 20 per end) Shelf Lamps (up to 20 per end)
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
THESE ARE MARKER COLORS (WIRE MAY VARY.)
R = Red P = Purple 2P = Purple (2 Bands)
DB = Dark Blue B = Black
BR =Brown Y =Yellow OR = Orange W = White
= 120V POWER = 120V NEUTRAL = FIELD GROUND
= CASE GROUND
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
Black
15 14 14 15
LifeLine Premier
Stand Alone Dry Goods Kit
RL With INNOVATOR Doors
Frozen Food & Ice Cream