Hussmann LIE, LIE FF, LIE IC Technical Data Sheet

Page 1
B
A
E
F
C
G
D
P/N 0469082_A
®
Technical Data Sheet
P/N 0469082_A
NSF
®
Certified
February 2007
Item Part # Description Wiring Item #
FAN ASSEMBLIES AND THERMOSTATS
A. 4W Fan Assembly (1)
0392457 Fan Motor, Standard (MO.4410101) 0409511 Fan Blade, embossing toward motor
(FB.0409511)
B. Optional Adjustable Refrigeration Thermostat (2)
C. 0398557 Defrost Termination Thermostat (3)
(Electric Defrost only) (CT.4440611)
D. 0425304 Heater Switch (4)
(Koolgas Defrost only) (CT.0425304)
Item Part # Description Wiring Item #
HEATERS
E. 0395709 Modular Electric
Defrost Heaters, 208V (5) (HE.4850409)
F. 0392412 Drip Pan Heaters, Electric 208V (6)
(HE.4850461)
F. 0421237 Drip Pan Heaters, Koolgas 120V (7)
(HE.4850495)
G. Nosing Anti-sweat Heaters (8)
009992P Discharge (HE.4850681) 0401555 Return (HE.4850465)
©2007 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
NOTE: Revision A corrects heater data on Page 4.
Merchandisers
Page 2
LIE Technical Data Sheet2 of 6
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Engineering
Plan Views
Dimensions shown as inches & (mm).
End Case
General
Case Length (without ends or partitions) 43 (1092)
(Each end and insulated partition adds 2 in. (51 mm) to case line up.)
Maximum O/S dimension of case back to front (includes bumper) 56 3/
4 (1442)
Front of splashguard to O/S edge of front base rail 8
1
/
2 (216)
Back of case to O/S edge of front base rail 44
1
/
4 (1124)
Front of case to O/S edge of front base rail 12
1
/
2 (318)
Width of base rail 2
1
/
8 (54)
Stub-up area (gray) between front base rail and splashguard 7
5
/
8 (194)
Electrical Service (Electrical Field Wiring connection point)
LH End of case to center of first knockout 6
3
/4 (172)
Back O/S edge of case to nearest knockout 9 7/8 (251)
Waste Outlets
LH End of case to the center of waste outlet 9 7/8 (251) Back O/S of case to center of waste outlet 43 (1092)
Water Seal
Edge of water seal to center of waste outlet 11 (279) O/S diameter of drip pipe lines 1 1/2 (38) Note: Field installed water seal outlet, tees and connectors are shipped with case.
Refrigeration Outlet
LH end of case to center of front and rear refrigeration outlets 12 3/8 (314) Front or rear of case to center of front and rear refrigeration outlets 6 1/4 (83)
Single Deck Frozen Food
Intermediate Island End
12
9
7/8
(249)
3/8
(314)
43
(1092)
LIE
Electrical
6
3/4
(170)
C
L
25
(635)
43
(1092)
44
1/4
(1123)
56
3/4
(1441)
Waste
9
7/8
(249)
Outlet
Refrig. Outlet
8
Access Area
(Gray)
Front
1/2
(214)
6
1/4
(159)
12
(318)
1/2
Page 3
REFRIGERATION DATA
Note: This data is based on store temperature
and humidity that does not exceed 75°F and 55% R.H.
FF IC
Discharge Air (°F) –12 –22
Evaporator (°F) –20 –30
Unit Sizing (°F) –23 –33
Btu/hr/case FF IC
Parallel
1365 1396
Conventional
1410 1441
DEFROST DATA
FF IC
Frequency (hr) 24 24 Defrost Water (lb/ft/day) 0.75 0.60
(± 15% based on case configuration and product
loading).
E
LECTRIC
FF IC
Temp Term (°F) 48° 48° Failsafe (minutes) 60 60
GAS
Duration (minutes) 15 18
O
FFTIME Not Recommended
Standard Defrost Thermostat
Close on rise: close 48°F — open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control
FF IC
CI/CO (Temp °F)* – 27/–39 –27/–39
Indoor Unit Only, Pressure Defrost Termination (Temp °F) Not Recommended
*Use a Temperature Pressure Chart to determine PSIG conversions.
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/
4
Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
5
/8
Estimated Charge (lb)**
End Case 1.1
**This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound.
Length Added to Lineup by: Each End/Partition (in.) 1
1
/2
Each Contoured End (in.) 5
3 of 6
P/N 0469082_A
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Dimensions shown in inches & (mm).
Impact
LIE
Frozen Food & Ice Cream
Single Level Free Standing End Island Display
NSF Certification
These merchandisers are manufactured to meet ANSI /National Sanitation Foundation (NSF
®
) Standard #7 requirements.
LIE
3
14
/4
35
(902)
1
/
2
30
(762)
(375)
32
(862)
FA N
1
8
/
4
5
(210)
(127)
34
40
43
(1092)
15
/16
COIL
25
(635)
30
31
5/8 (803)
33
1/8 (843)
1/2 (876)
1
/4 (1021)
(762)
7 (178)
Page 4
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
LIE Technical Data Sheet4 of 6
Impact LIE
Frozen Food & Ice Cream
Electrical Data
End
Number of Fans – 4W 1
(Energy Efficient fan motors are not available for End or End-compartment models)
Amperes Watts
8 ft 8 ft
Evaporator Fans
120V 60Hz Standard 0.31 24
120V 50Hz Standard NA
230V 60Hz Export 0.15 24
230V 50Hz Export 0.18 27
120V 60Hz Energy Efficient 0.14 10
230V 60Hz Energy Efficient NA
Nosing Anti-sweat Heaters (on fan circuit)
120V 60Hz Standard 0.63 76
230V 50Hz Export 0.34 76
Cycling Anti-sweat Heaters NA
230V 50Hz Export NA
Minimum Circuit Ampacity
120V 60Hz Standard 1.09
120V 50Hz Standard NA
230V 60Hz Export 0.69
230V 50Hz Export 0.72
120V 60Hz Energy Efficient 0.97
230V 60Hz Energy Efficient NA
Maximum Over Current Protection 120V 20
Maximum Over Current Protection 230V 15
Electric Defrost Heaters
208V 60Hz Standard 5.5 1150
230V 50Hz Export 6.1 1403
Koolgas Drip Pan Heaters
120V 60Hz Standard 1.25 150
230V 50Hz Export NA
Standard Lighting: None
Page 5
5 of 6
P/N 0469082_A
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
Circled Numbers = Parts List Item Numbers
120V POWER
120V NEUTRAL
BROWN BAND
Fan
BROWN BAND
Nosing (anti-sweat) Heater
1
8
208 V Power From Defrost Contactors
L1
L2
Drip Pan Heater
Modular Electric Defrost Heater
5
6
Defrost
Termination
Thermostat
Refrigeration
Thermostat
Dark Blue
To Condensing Unit
}
Light Blue
3
2
(Field Installed)
Electric Defrost – Standard
Page 6
Gas Defrost – Optional
LIE Technical Data Sheet6 of 6
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
120V POWER
BROWN BAND
Fans
Yellow
Dark Blue
Heater Switch
4
1
8
Nosing (anti-sweat) Heaters
Drip Pan Heater
7
120V NEUTRAL
BROWN BAND
Yellow
Dark Blue
120V POWER
120V NEUTRAL
Refrigeration
Thermostat
2
(Field Installed)
Light Blue
To
}
Condensing Unit
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
Circled Numbers = Parts List Item Numbers
Grayed components in 12 foot models only.
Loading...