Hussmann LI Technical Data Sheet

B
E
F
C
D
A
G
P/N 0395735_H
®
Technical Data Sheet
P/N 0395735_H
NSF
®
Certified
February 2007
Item Part # Description Wiring Item #
FANASSEMBLIES AND THERMOSTATS
A. 4W Fan Assembly (1)
0392457 Fan Motor, Standard (MO.4410101) 0409511 Fan Blade, embossing toward motor
(FB.0409511)
B. Optional Adjustable Refrigeration Thermostat (2)
C. 0398557 Defrost Termination Thermostat (3)
(Electric Defrost only)
(CT.4440611)
D. 0425304 Heater Switch (4)
(Koolgas Defrost only)
(CT.0425304)
Item Part # Description Wiring Item #
H
EATERS
E. 0395709 Modular Electric
Defrost Heaters, 208V (5) (HE.4850409)
F. Drip Pan Heaters, Electric 208V (6)
0392413 8 foot case (HE.0392413) 0392414 12 foot case (HE.0392414)
Drip Pan Heaters, Koolgas 120V (7) 0421238 8 foot case (HE.4850496)
0421239 12 foot case (HE.4850497)
G. Nosing Anti-sweat Heaters (8)
0401605 8 foot case (Discharge) (HE.0401605) 0401557 8 foot case (Return) (HE.4850467) 0401606 12 foot case (Discharge) (HE.4850471) 0401558 12 foot case (Return) (HE.4850468)
©2007 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
NOTE: Revision H corrects heater data on Page 4.
Merchandisers
LI Technical Data Sheet2 of 6
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Engineering
Plan Views
Dimensions shown as inches & (mm).
8 ft 12 ft
General
(A) Case Length (without ends or partitions) 96 1/4 (2445) 144 1/2 (3670)
(Each end and insulated partition adds 2 in. (51 mm) to case line up.)
Maximum O/S dimension of case back to front (includes bumper) 56 3/4 (1442) 56 3/4 (1442) Back of case to front of splashguard 52 1/2 (1334) 52 1/2 (1334) Back of case to O/S edge of front base rail 44 (1118) 44 (1118) Width of base rail 2 1/8 (54) 2 1/8 (54) Stub-up area (gray) between base rail and splashguard 7 5/8 (194) 7 5/8 (194)
Electrical Service (Electrical Field Wiring connection point)
RH End of case to center of nearest knockout 5 (127) 5 (127) Back O/S of case to center of knockout 50 1/2 (1283) 50 1/2 (1283)
Waste Outlets
(B) RH End of case to the center of waste outlet 19 3/4 (502) 76 1/2 (1943)
LH End of case to center of waste outlet 38 (965) 76 5/8 (1946) Back O/S of case to center of waste outlet 473/8 (1203) 473/8 (1203)
Water Seal
Edge of water seal to center of waste outlet 11 (279) 11 (279) O/S diameter of drip pipe lines 1 1/2 (38) 1 1/2 (38) Note*: Field installed water seal outlet, tees and connectors are shipped with case.
Refrigeration Outlet
RH end of case to center of RH refrigeration outlet 5 9/16 (141) 5 9/16 (141)
(C) LH end of case to center of LH refrigeration outlet 88 3/8 (2245) 138 7/8 (3527)
Back O/S of case to center of refrigeration outlet 44 3/4 (1137) 44 3/4 (1137)
Low Temperature
Intermediate Wide
Island Models
LI
Base Rail
A
Waste Outlet
C
B
44
44 3/4
31
1/8
(1137)
5
(141)
Refrig. Outlet
9/16
(1115)
(1137)
47
3/8
(1203)
50
(1282)
1/2
52
(1335)
1/2
56
3/4
(1440)
Access Area
(Gray)
Front
Electrical
Water Seal
(See Note*)
2 7/8
(98)
5
(127)