Hussmann LI Technical Data Sheet

Page 1
B
E
F
C
D
A
G
P/N 0395735_H
®
Technical Data Sheet
P/N 0395735_H
NSF
®
Certified
February 2007
Item Part # Description Wiring Item #
FANASSEMBLIES AND THERMOSTATS
A. 4W Fan Assembly (1)
0392457 Fan Motor, Standard (MO.4410101) 0409511 Fan Blade, embossing toward motor
(FB.0409511)
B. Optional Adjustable Refrigeration Thermostat (2)
C. 0398557 Defrost Termination Thermostat (3)
(Electric Defrost only)
(CT.4440611)
D. 0425304 Heater Switch (4)
(Koolgas Defrost only)
(CT.0425304)
Item Part # Description Wiring Item #
H
EATERS
E. 0395709 Modular Electric
Defrost Heaters, 208V (5) (HE.4850409)
F. Drip Pan Heaters, Electric 208V (6)
0392413 8 foot case (HE.0392413) 0392414 12 foot case (HE.0392414)
Drip Pan Heaters, Koolgas 120V (7) 0421238 8 foot case (HE.4850496)
0421239 12 foot case (HE.4850497)
G. Nosing Anti-sweat Heaters (8)
0401605 8 foot case (Discharge) (HE.0401605) 0401557 8 foot case (Return) (HE.4850467) 0401606 12 foot case (Discharge) (HE.4850471) 0401558 12 foot case (Return) (HE.4850468)
©2007 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
NOTE: Revision H corrects heater data on Page 4.
Merchandisers
Page 2
LI Technical Data Sheet2 of 6
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Engineering
Plan Views
Dimensions shown as inches & (mm).
8 ft 12 ft
General
(A) Case Length (without ends or partitions) 96 1/4 (2445) 144 1/2 (3670)
(Each end and insulated partition adds 2 in. (51 mm) to case line up.)
Maximum O/S dimension of case back to front (includes bumper) 56 3/4 (1442) 56 3/4 (1442) Back of case to front of splashguard 52 1/2 (1334) 52 1/2 (1334) Back of case to O/S edge of front base rail 44 (1118) 44 (1118) Width of base rail 2 1/8 (54) 2 1/8 (54) Stub-up area (gray) between base rail and splashguard 7 5/8 (194) 7 5/8 (194)
Electrical Service (Electrical Field Wiring connection point)
RH End of case to center of nearest knockout 5 (127) 5 (127) Back O/S of case to center of knockout 50 1/2 (1283) 50 1/2 (1283)
Waste Outlets
(B) RH End of case to the center of waste outlet 19 3/4 (502) 76 1/2 (1943)
LH End of case to center of waste outlet 38 (965) 76 5/8 (1946) Back O/S of case to center of waste outlet 473/8 (1203) 473/8 (1203)
Water Seal
Edge of water seal to center of waste outlet 11 (279) 11 (279) O/S diameter of drip pipe lines 1 1/2 (38) 1 1/2 (38) Note*: Field installed water seal outlet, tees and connectors are shipped with case.
Refrigeration Outlet
RH end of case to center of RH refrigeration outlet 5 9/16 (141) 5 9/16 (141)
(C) LH end of case to center of LH refrigeration outlet 88 3/8 (2245) 138 7/8 (3527)
Back O/S of case to center of refrigeration outlet 44 3/4 (1137) 44 3/4 (1137)
Low Temperature
Intermediate Wide
Island Models
LI
Base Rail
A
Waste Outlet
C
B
44
44 3/4
31
1/8
(1137)
5
(141)
Refrig. Outlet
9/16
(1115)
(1137)
47
3/8
(1203)
50
(1282)
1/2
52
(1335)
1/2
56
3/4
(1440)
Access Area
(Gray)
Front
Electrical
Water Seal
(See Note*)
2 7/8
(98)
5
(127)
Page 3
3 of 6P/N 0395735_H
Impact LI
Frozen Food & Ice Cream
Single Level Intermediate Island Display
Dimensions shown in inches & (mm).
NSF Certification
These merchandisers are manufactured to meet ANSI /National Sanitation Foundation (NSF®) Standard #7 requirements.
REFRIGERATION DATA
Note: This data is based on store temperature
and humidity that does not exceed 75°F and 55% R.H.
FF IC
Discharge Air (°F) –12 –22
Evaporator (°F) –20 –30
Unit Sizing (°F) –23 –33
Btu/hr/ft FF IC
Parallel
460 470
Conventional
475 485
DEFROST DATA
FF IC
Frequency (hr) 24 24 Defrost Water (lb/ft/day) 0.75 0.60
(± 15% based on case configuration and product
loading).
ELECTRIC FF IC
Temp Term (°F) 48° 48° Failsafe (minutes) 60 60
GAS
Duration (minutes) 15 18
O
FFTIME Not Recommended
Standard Defrost Thermostat
Close on rise: close 48°F — open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control
FF IC
CI/CO (Temp °F)* – 27/–39 –27/–39
Indoor Unit Only, Pressure Defrost Termination (Temp °F)*
Not Recommended
*Use a Temperature Pressure Chart to determine PSIG conversions.
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/4 Merchandiser Liquid Line (in.)
3
/
8
Merchandiser Suction Line (in.)
7
/8
Estimated Charge (lb)**
8 ft 1.7
12 ft 2.6
**This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound.
Length Added to Lineup by: Each End/Partition (in.) 1
1
/
2
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
LI
3
14
/4
35
(902)
1
/
2
30
(762)
(375)
44
(1118)
FAN
COIL
8
(210)
1
/
4
5
(127)
31
56
1
52
/
50
3/
8
44
44
47
1/
4
(791)
3/
1/
2
2
(1440)
3/
(1335)
(1115)
(1137)
4
(1203)
8
(1282)
7(178)
Page 4
LI Technical Data Sheet4 of 6
Impact
LI
Frozen Food & Ice Cream
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Electrical Data
8 ft 12 ft
Number of Fans – 4W 2 3
(Energy Efficient fan motors are not available for End or End-compartment models)
Amperes Watts
8 ft 12 ft 8 ft 12 ft
Evaporator Fans
120V 60Hz Standard 0.62 0.93 48 72
120V 50Hz Standard NA
230V 60Hz Export 0.30 0.45 48 72
230V 50Hz Export 0.36 0.54 54 81
120V 60Hz Energy Efficient 0.28 0.42 20 30
230V 60Hz Energy Efficient NA
Nosing Anti-sweat Heaters (on fan circuit)
120V 60Hz Standard 0.94 1.40 112 168
230V 50Hz Export 0.49 0.73 112 168
Cycling Anti-sweat Heaters NA
230V 50hz Export NA
Minimum Circuit Ampacity
120V 60Hz Standard 1.76 2.53
120V 50Hz Standard NA
230V 60Hz Export 0.99 1.38
230V 50Hz Export 1.05 1.47
120V 60Hz Energy Efficient 1.42 2.02
230V 60Hz Energy Efficient NA
Maximum Over Current Protection 120V 20 20
Maximum Over Current Protection 230V 15 15
Electric Defrost Heaters
208V 60Hz Standard 8.0 12.0 1670 2505
230V 50Hz Export 8.9 13.3 2040 3060
Koolgas Drip Pan Heaters
120V 60Hz Standard 2.50 3.75 300 450
230V 50Hz Export NA
Standard Lighting: None
Page 5
5 of 6P/N 0395735_H
Electric Defrost – Standard
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
L1
120V POWER
BROWN BAND
208 V Power From Defrost Contactors
Drip Pan Heater
6
Red
Modular Electric Defrost Heaters
Fans
1
8
Nosing (anti-sweat) Heaters
5
BROWN BAND
L2
Red
120V NEUTRAL
Refrigeration
2
Defrost Termination Thermostat
3
Dark Blue
Thermostat
(Field Installed)
Light Blue
}
To Condensing Unit
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
Circled Numbers = Parts List Item Numbers
Grayed components in 12 foot models only.
Page 6
Gas Defrost – Optional
LI Technical Data Sheet6 of 6
BROWN BAND
Fans
BROWN BAND
Nosing (anti-sweat) Heaters
120V POWER
120V NEUTRAL
1
8
Refrigeration
Thermostat
To Condensing Unit
}
Light Blue
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
Circled Numbers = Parts List Item Numbers
Grayed components in 12 foot models only.
(Field Installed)
2
7
4
Drip Pan Heater
Yellow
Heater Switch
Yellow
120V POWER
120V NEUTRAL
Dark Blue
Dark Blue
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Loading...