Hussmann LGH, LGH FF, LGH IC Technical Data Sheet

B
C
E
D
I
I
G
H
A
F
P/N 0430137_B
LGH
Technical Data Sheet
P/N 0430137_B
NSF
®
Certified
February 2007
Item Part # Description Wiring Item #
F
AN ASSEMBLIES AND THERMOSTATS
A. 4W Fan Assembly (1)
0392457 Fan Motor, Standard (MO.4410101) 0409511 Fan Blade, embossing toward motor
(FB.0409511)
B. Optional Adjustable Refrigeration Thermostat, (2)
C. 0398557 Defrost Termination Thermostat (3)
(Electric Defrost only)
(CT.4440611)
D. 0425304 Heater Switch (4)
(Koolgas Defrost only) (CT.0425304)
HEATERS
E. 0400543 Control-Glass Anti-sweat Heaters
(Export) Defrost Heaters, 208V (5) (CT.4480905)
F. 0395709 Modular Electric
Defrost Heaters, 208V (6) (HE.4850409)
Item Part # Description Wiring Item #
H
EATERS (CONTINUED)
G. Drip Pan Heaters, Electric 208V (7)
0392413 8 foot case (HE.0392413) 0392414 12 foot case (HE.0392414)
Drip Pan Heaters, Koolgas 120V (8) 0421238 8 foot case (HE.4850496)
0421239 12 foot case (HE.4850497)
H. Nosing Anti-sweat Heaters (9)
0401605 Discharge Nosing 8 foot case
(HE.0401605)
0401606 Discharge Nosing 12 foot case
(HE.4850471)
I. Multiglass-2 Pane,
(Anti-sweat Heaters) (10)
0420156 8 foot case
(Return) (GL.4985203)
0420157 12 foot case (Return) (GL.4985204) 0420168 L.H. End (GL.4985209) 0420169 R.H. End (GL.4985286)
©2007 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
NOTE: Revision B corrects heater data on Page 4.
Merchandisers
LGH Technical Data Sheet2 of 7
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Engineering
Plan Views
Dimensions shown as inches & (mm).
8 ft 12 ft
General
(A) Case Length (without ends or partitions) 96 1/
4 (2445) 144
1
/
2 (3670)
(Each end and insulated partition adds 2 in. (51 mm) to case line up.)
Maximum O/S dimension of case back to front (includes bumper) 43 (1092) 43 (1092) Back of case to front of splashguard 38 7/
8 (987) 38
7
/
8 (987)
Back of case to O/S edge of front base rail 29
5
/
8 (753) 29
5
/
8 (753)
Width of base rail 2
1
/
8 (54) 2
1
/
8 (54)
Stub-up area (gray) between base rail and splashguard 7
5
/
8 (194) 7
5
/
8 (194)
Electrical Service (Electrical Field Wiring connection point)
RH End of case to center of nearest knockout 5 (127) 5 (127) Back O/S of case to center of knockout 36
1
/4 (921) 36 1/4 (921)
Waste Outlets
(B) RH End of case to the center of waste outlet 58 1/4 (1480) 67 7/8 (1724)
LH End of case to center of waste outlet 38 (965) 76 5/8 (1946) Back O/S of case to center of waste outlet 33 (838) 33 (838)
Water Seal
Edge of water seal to center of waste outlet 11 (279) 11 (279) O/S diameter of drip pipe lines 1 1/2 (38) 1 1/2 (38) Note*: Field installed water seal outlet, tees and connectors are shipped with case.
Refrigeration Outlet
RH end of case to center of RH refrigeration outlet 5 9/16 (141) 5 9/16 (141)
(C) LH end of case to center of LH refrigeration outlet 88 3/8 (2245) 138 7/8 (3527)
Back O/S of case to center of refrigeration outlet 30 9/16 (776) 30 9/16 (776)
Low Temperature
Single Deck Wall Models
LGH
Base Rail
Access Area
(Gray)
A
Waste Outlet
Front
C
Water Seal
(See Note *)
Electrical
B
29
5/8
30
5
9/16
(141)
Refrig. Outlet
2
7/8
(98)
5
(127)
(753)
9/16
(776)
33
(838)
36
(921)
1/4
38
(987)
7/8
43
(1092)
3 of 7P/N 0430137_B
Impact LGH
Frozen Food & Ice Cream
Single Level Wall Island High Front Display
Dimensions shown in inches & (mm).
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
REFRIGERATION DATA
Note: This data is based on store temperature and humidity that does not exceed 75°F and 55% R.H.
FF IC Discharge Air (°F) –12 –22 Evaporator(°F) –20 –30 Unit Sizing (°F) –23 –33
Btu/hr/ft FF IC Parallel
425 435
Conventional
440 450
DEFROST DATA
FF IC Frequency (hr) 24 24
Defrost Water (lb/ft/day) 0.75 0.60
(± 15% based on case configuration and product
loading).
ELECTRIC FF IC
Temp Term (°F) 48° 48° Failsafe (minutes) 60 60
GAS
Duration (minutes) 15 18
O
FFTIME
Not Recommended
Standard Defrost Thermostat
Close on rise: close 48°F — open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control
FF IC
CI/CO (Temp °F)* -27°/-39° -27°/-39°
Indoor Unit Only, Pressure Defrost Termination* Not Recommended
*Use a Temperature Pressure Chart to determine PSIG conversions.
PHYSICAL DATA
Drip Pipe (in.) 1 1/4 Liquid Line (in.)
3
/
8
Suction Line (in.)
5
/8
Estimated Charge (lb)**
8 ft 1.7
12 ft 2.6
**This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound.
Length Added to Lineup by Each End/Partition (in.) 1 1/2
NSF Certification
These merchandisers are manufactured to meet ANSI /National Sanitation Foundation (NSF®) Standard #7 requirements.
LGH
10
(254)
32
(832)
36
(914)
15
(381)
26
(660)
8
(210)
1
/
4
5
(127)
FAN
19
1/
8
33 (838)
36
38
43
(1092)
3/
4
COIL
(486)
29
5/
30
9/
16
1/4 (921)
7/8 (987)
8
(753)
(776)
7 (178)
35
(889)
Loading...
+ 4 hidden pages