Air Distribution and Rear Flue Spacer 3
Serial Plate Information Electrical Connections 4
Electrical, BTU Capacities 4
Initial Start Up and Loading 4
General Upkeep and Cleaning 5
Power Switches, Temperature Controls 5
Thermometer 6
Electrical Enclosure 6
Lighting 6
Refrigeration 7
Leak Testing 7
Evacuation 7
Operational Data and Refrigerant Control 8
Trouble Shooting, and Lights Trouble Shooting 9 & 10
Warranty and Electrical Components Replacement List 11 & 12
Commercial Door Literature 13-16
Page 1
Introduction –
The HGM-BS/TS models are self contained, medium temperature, vertical glass
door merchandisers designed for the display
of dairy products, deli items, beverages, and
wine. Design features include self-closing
glass doors, efficient foamed in place nonCFC insulation, and balanced R-134a refrigeration systems for energy saving performance.
Inspection upon receipt –
Upon receipt of the cabinet, carefully
examine the crating for damage. If crate is
damaged, make a note on the delivery ticket
before signing. Carefully remove shipping
crate and examine cabinet for “concealed”
damage. If damage is found, contact the delivery carrier immediately and have his agent
prepare an inspection report for the purpose
of filing a claim. THIS IS YOUR RESPONSIBILITY.
Proper Location & Clearance –
allowed in front of the case and six (6) inches of
clearance at the rear to provide the necessary
free air movement to and from the condenser.
INITIAL SET-UP Skid –
The skid should be left on the case until it
is near its final location. The skid provides protection for both case and floor. The skid is removed by raising one end of the case approximately six inches. Block securely and remove
the two skid bolts on the raised end. The procedure is repeated on the opposite end. When the
skid bolts are removed, the case may be slid off
the skid.
Leg Installation – Top Mounts only
After the case is near its final location
and the skid has been removed, the NSF approved legs should b e installed. The legs are
packaged inside the cabinet. Replace the tape
and door blocks. To install legs, raise one end of
the cabinet approximately eight (8) inches, block
securely, and install two legs.
Avoid locating the cabinet where direct
sunlight would shine into the fixture or where
drafts from air conditioning grills, fans and
open doors could affect its operation.
Because the condensing unit is located
at the top of the HGM-TS, at least twelve (12)
inches of clearance should be allowed at the
rear of the cabinet and at the top of the case.
This clearance is necessary to provide free air
movement to and from the condenser for
maximum operating efficiency.
Because the condensing unit is located
on the bottom of the HGM-BS, at least twenty
four (24) inches of clearance should be
Page 2
The leg mounting plates are factory installed and contain a ½ x 13 tapped hole to mate
with the leg assembly. The procedure is repeated on the opposite end. The 3-door requires
legs in the center. With cabinet legs installed,
the cabinet should be positioned in its final location and leveled.
The cabinet is leveled by turning the bottom section of each leg. The self-closing doors require
the cabinet to be properly leveled. End to end
leveling will make the door (s) close with uniform speed and tightness. A slight pitch from
front to rear is desirable.
THE CABINET BACK SHOULD
NEVER BE HIGHER THAN THE FRONT.
electrical box to allow the electrical box to
slide out for servicing.
Leveling and Sealing
– Bottom
Mounts only
The case can be leveled by shimming under the cabinet base frame, or be installing optional levelers. The self-closing doors require
the cabinet to be properly leveled. End to end
leveling will make the door (s) close with uniform speed and tightness. A slight pitch from
front to rear is desirable.
Silicone Sealant
Condensate Pan –
Floor
An electrically heated (300w, 115v) condensate pan is provided to evaporate the defrost
water. The heated condensate pan slides onto
the slide plate on the cabinet bottom on TS
cases and has a thermistor. On BS cases the
pan is screwed to the base of the case. The pan
is removable for cleaning. A vinyl drain tube is
provided for connection to the heated condensate pan. The drain must be trapped to guard
against drain line freezing and for good sanitation practice.
Bottom Louvered Panel Removal –
The louvered panel provides access to
the condensing unit and the electrical box.
Remove panel by removing the shipping
screw (s) at bottom and lifting up and pulling
forward. Remove shipping screw on
Top Decorative Panel Removal –
The top decorative panel is removed by
lifting up and pulling forward.
Shelves
–
Each cabinet is provided with 4 cantilever shelves per door that are adjustable on 1inch increments and are tiltable. Each cabinet
also has one bottom shelf per door. These
shelves have one-inch legs to allow proper airflow in the cabinet. Behind the shelves are
wire flue spacers which also allow for proper
airflow. All shelves and flue spacers are white,
epoxy coated for durability and ease of cleaning. Shelves should be adjusted to desired operating height.
When loading product, into the cabinet,
care should be taken not to load product so
that it touches the evaporator coil cover. Do
not extend product past the front edge of the
shelf. Extending past the edge will seriously
effect internal air flow through out the cabinet.
Shelves are UL rated for a maximum
load of 123 lbs. DO NOT OVERLOAD
SHELVES.
Air Distribution and
Rear Flue Spacer –
Air is drawn through the evaporator
from front to rear and is discharged down the
back wall, returning up the face of the glass
door to the return air grill. NOTE: Rear flue
Page 3
spacer must be in place as this forms a discharge air flue at the back of the cabinet.
Electrical Connections –
The HGM-1 and 2 cases are supplied
with a supply cord as charted below with a
grounding prong for operation on a 115v power
supply. Do not remove the grounding prong
under any circumstances. The HGM-3 requires
hard wiring to a 30 amp, 115v circuit.
Cord Plug Nema
Model Amperage Designation
HGM-1-BS/TS 15 5 – 15 P
HGM-2-BS/TS 20 5 – 20 P
Serial Plate Information –
The serial plate is located in the upper
left-hand corner of the case interior. It has all
the pertinent information needed for proper
electrical installation. The serial plate should
not be removed for any reason.
NOTE: Connecting this unit to any electrical
supply other than specified on the serial plate
will void the warranty and may result in serious
damage with its own service.
The HGM cases use R-134a refrigerant. Check the serial plate for the specific refrigerant
charge used.
Page 4
Initial Start-up and Loading –
Check the cabinet thoroughly for loose nuts
and bolts and electrical connections. Inspect the refrigeration lines for any visible
damage or chafing.
Replace the electrical box cover.
Start the cabinet and allow to pull down to
operating temperature before loading.
General Upkeep and Cleaning –
1. To insure good sanitation, appearance, and
minimum maintenance, the cabinet should
be cleaned and washed regularly as sue demands. Clean with mile detergent and
warm water. DO NOT USE AN ABRASIVE CLEANER OR STEEL WOOL AS
THEN WILL MAR THE FINISH.
1. Under normal conditions, after the cabinet
is installed and running, very little maintenance should be required. However, the following list of housekeeping practices will
assure trouble-free operation.
a) Check operation of condenser fan motors.
Fan blades must turn freely.
a) Check drain pan and heater to prevent acci-
dental overflow.
a) Make sure doors are closing properly and
that the gaskets seal.
a) Make sure all evaporator fan motors are
running. These can be seen through grill
inside cabinet.
a) Clean the cabinet with a mild detergent.
this will insure good sanitation, and minimize maintenance. Never use an abrasive as
this could mar the finish.
a) A regular program should be set up for the
cleaning of the fin-and-tube condenser.
Normally, this cleaning is required every 3
to 4 months, but the individual store application may shorten or lengthen this time period. Dust and dirt accumulation can cause
serious efficiency loss.
a) On the BS cases (bottom mounts) access is
gained to the unit area by removing the louvered grille. The unit slides forward to facilitate cleaning and for service. Care
should be taken when pushing the unit back
in place to insure that the pullout coil does
not become kinked or damaged in some
way.
OPERATION AND MAINTENANCE
Power Switches –
The power switch is located at the electrical box which is behind the top decorative
panel (TS models) or bottom louvered panel
(BS models). The switch will shut off al power
to the case.
Temperature Control –
The electrical temperature control is located in
the electrical box. The temperature control
does not have an ‘OFF’ position.
Adjustments may be made by turning
the knob on the face of the dial. Turning it
clockwise will give warmer temperatures while
counter-clockwise will give colder temperatures.
Page 5
There is also and adjustable temperature differential (the difference between the cutin temperature and the cut-out temperature)
located on the back of the temperature control
cover. When adjusting the differential, the temperature setting may also have to be adjusted.
See figure below for internal adjustment locations.
The control has a range of –20º F to
+220º F with a differential of 1º to 30º. It is factory set for approximately 29ºF with a 10º differential. The temperature should be checked
with a thermometer other than the case thermometer after it is running to insure that the
case is running at the proper temperature for
the product.
A picture of A319 Electronic Temperature Control and Board Layout is located on
the last page of this booklet.
Thermometer –
The thermometer is located by looking
through the right hand door onto the right
hand end of the fan plenum.
The thermometer will also warm up
rather rapidly when the case door is held open
for a time such as when the case is being restocked or a shopper is making a decision on a
product. After the door is closed it will take
some time for the thermometer to pull back
down to the case temperature. The thermometer and temperature control sense discharge air
temperature which is 5-10º colder than the case
temperature.
The thermometer may be replaced by
removing the two screws securing it to the
evaporator fan grill. Lower the evaporator coil
cover by removing the brass thumb screws
located at each end of the cover, and backing
out the thumb screws located along the front
edge of the cover.
Follow the sensing lead from the thermometer until you locate the sensing element.
Loosen the clamp securing the element and remove the element. Remove the thermometer.
Assemble is the reverse order making sure you
first thread the element through the hole in the
evaporator fan grill. Cleaning of the sensing
element may also be accomplished in this manner.
Electrical Enclosure –
For servicing convenience, access is
gained by removing the access panel and electrical box cover. The cabinet supply breakers
should be disconnected before removing the enclosure cover.
Lighting –
Electronically powered T-8 lamps located inside each doorway provide interior
lighting. The tubes are enclosed in a patented
lens system to maintain proper heat around the
bulb for maximum light intensity and to protect
the product in case of breakage. See the
Commercial instructions for the lens removal,
attached at the back of this booklet.
Each HGM model has a convenient ON/
OFF switch so lights may be turned off to conserve energy during hours when the store is
closed. The switch is located inside the cabinet
above the left hand door. This switch only controls the lights. 115 volt power must be shut off
at the main power supply source located within
the store prior to starting any service or maintenance work.