Hussmann FWG Specifications

Item Part # Description Wiring Item #
F
AN ASSEMBLIES, AND THERMOSTATS
A. 4W Standard Fan Assembly (1)
0392457 Fan Motor, Evaporator
(MO.4410101)
0464847 Fan Blade (FB.4780649) 4W Energy Efficient Fan Assembly (1) 0477653 Fan Motor, Evaporator
(MO.4410544)
0464847 Fan Blade (FB.4780649)
C. 0398557 Defrost Termination Thermostat (3)
(Front/Electric Defrost only) (CT.4440611)
D. 0398558 Defrost Termination Thermostat (3)
(Rear/Electric Defrost only) (CT.4481088)
E. 0481370 Heater Switch (4)
(Koolgas Defrost only) (CT.4440738)
H
EATERS
F. 208V Evaporator Defrost Heaters (5)
0481864 4 ft case (HE.4850637) 0444057 6 ft case (HE.4850620) 0462159 8 ft case (HE.4850603) 0444058 12 ft case (HE.4850571)
Item Part # Description Wiring Item #
H
EATERS (CONTINUED)
G. 208V Drip Pan Defrost Heaters, Electric (6)
0481865 4 ft case (HE.4850638) 0444300 6 ft case (HE.4850609) 0462160 8 ft case (HE.4850636) 0444296 12 ft case (HE.4850572)
120V Drip Pan Defrost Heaters, Koolgas (7) 0488967 4 ft case (HE.4850641) 0465906 6 ft case (HE.4850628) 0465907 8 ft case (HE.4850622) 0465908 12 ft case (HE.4850623)
H. Nosing Anti-sweat Heaters (8)
0495009 4 ft case (HE.4850687) 0495006 6 ft case (HE.4850684) 0495007 8 ft case (HE.4850685) 0495008 12 ft case (HE.4850686)
I. Return Grille Anti-sweat Heaters (9)
0495013 4 ft case (HE.4850691) 0495010 6 ft case (HE.4850688 ) 0495011 8 ft case (HE.4850689) 0495012 12 ft case (HE.4850690)
J. Return Glass Anti-sweat Heaters (10)
0481867 4 ft case (GL.4978594) 0474775 6 ft case (GL.4977903) 0474778 8 ft case (GL.4987838) 0474779 12 ft case (GL.4987839)
B
D
G
E
F
C
A
H
I
J
E
P/N 0465901_G
FWG
Technical Data Sheet
P/N 0465901_G
NSF
®
Certified
December 2008
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
©2008 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
Note: Revision G adds note on reduced energy load with optional energy efficient motors (
Page 3).
2 of 7 FWG Technical Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
10 1/4 (261)
4 3/4 (120)
15 3/4
(400)
FRONT
C
Splashguard
12 1/8 (307)
A
B
D
Splashguard
8 1/2 (217)
Waste Outlet
29 1/2 (750)
Refrigeration
Outlet
Waste
Outlet
Waste
Outlet
80 5/8
(2046)
72
(1829)
64 1/2
(1638)
70 1/4
(1784)
59 3/4
(1515)
Electrical Field Connection
26 1/2 (673)
Wireway
Electrical
Stub Up Area
6 x 6
(152 x 152)
8 (203)
41 1/2
(1054)
43 7/8
(1114)
41 1/2
(1054)
4 1/4 (108)
4 1/2 (115)
Waste Outlet
20 3/4 (529)
Engineering
Plan Views
Dimensions shown as inches & (mm).
10-2004
Low / Medium Temperature
Wide Island
4 ft 6 ft 8 ft 12 ft
General
(A) Case Length (without ends or partitions) 48 1/4 (1226) 73 3/4 (1874) 96 3/8 (2448) 144 1/2 (3670)
(Each end and insulated partition adds 2 in. (51 mm) to case line up.)
Maximum O/S dimension of case back to front (includes bumper)
80 5/8 (2046) 80 5/8 (2046) 80 5/8 (2046) 80 5/8 (2046) Back of case to front of splashguard 72 (1829) 72 (1829) 72 (1829) 72 (1829) Back of case to O/S edge of front leg 59 3/4 (1515) 59 3/4 (1515) 59 3/4 (1515) 59 3/4 (1515) Distance between edges of external legs and center legs NA 30 1/4 (768) 41 1/2 (1054) 41 1/2 (1054) Distance between edges of center legs NA NA NA 43 7/
8 (1114)
Distance between front legs and splashguard 12
3
/8 (312) 12 3/8 (312) 12 3/8 (312) 12 3/8 (312)
Electrical Service (Electrical Field Wiring connection point)
(B) RH End of case to center of stub up area 36 1/8 (918) 61 5/8 (1565) 84 1/4 (2140) 132 3/8 (3363)
Back of case to center of stub up area 64 1/2 (1638) 64 1/2 (1638) 64 1/2 (1638) 64 1/2 (1638) Length of electrical wireway 26 1/2 (673) 26 1/2 (673) 26 1/2 (673) 26 1/2 (673)
(C) RH End of case to LH end of wireway 401/2 (1029) 67 1/2 (1715) 90 1/8 (2289) 138 1/4 (3511)
Waste Outlets (One each end)
(D) RH End of case to the center of LH waste outlet 36 1/8 (918) 61 5/8 (1565) 84 1/4 (2140) 132 3/8 (3363)
RH End of case to the center of RH waste outlet 12 1/
8 (307) 12
1
/
8 (307) 12
1
/
8 (307) 12
1
/
8 (307)
Back O/S of case to center of waste outlets 70
1
/4 (1784) 70 1/4 (1784) 70 1/4 (1784) 70 1/4 (1784)
Schedule 40 PVC drip pipe 1 1/4 (32) 1 1/4 (32) 1 1/4 (32) 1 1/4 (32)
Refrigeration Outlet
Back of case to center of front refrigeration outlet 64 7/8 (1646) 64 7/8 (1646) 64 7/8 (1646) 64 7/8 (1646) Back of case to center of rear refrigeration outlet 15 3/4 (400) 15 3/4 (400) 15 3/4 (400) 15 3/4 (400) RH end of case to center of refrigeration outlet 8 (203) 8 (203) 8 (203) 8 (203)
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/4 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
5
/8
Wireway
(12 Ft shown)
REFRIGERATION DATA
Note: This data is based on store temperature and humidity that does not exceed 75°F and 55% R.H.
MED FF IC
Discharge Air (°F) +24 –12 –22
Evaporator(°F) +19 –20 –30
Unit Sizing (°F) +17 –23 –33
Btu/hr/ft * M
ED FF IC
Parallel 440 625 670
Conventional 460 650 700
*Optional energy efficient motors reduce the
refrigeration load by 27 Btu/hr/ft (4 ft and 8 ft models)
and 18 Btu/hr/ft (12 ft models).
DEFROST DATA
M
ED FF IC
Frequency (hr) 24 24 24
Defrost Water (lb/ft/day) 2.2 2.1 1.8
(± 15% based on case configuration and product
loading).
ELECTRIC MED FF IC Temp Term (°F) 48 48 48 Failsafe (minutes) 60 60 60
GAS
Duration (minutes) NA 15 18
OFFTIME Not Recommended
Standard Defrost Thermostat
Close on rise: close 48°F — open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control — CI/CO **
M
ED +22°F / +10°F
FF –17°F / –29°F
IC –27°F / –39°F
Indoor Unit Only, Pressure Defrost Termination**
Not Recommended
**Use a Temperature Pressure Chart to determine
PSIG conversions.
Estimated Charge (lb)***
4 ft 1.7 6 ft 2.1 8 ft 2.5
12 ft 3.7
***This is an average for all refrigerant types. Actual
refrigerant charge may vary by approximately half a
pound.
3 of 7P/N 0465901_G
FAN
COIL
35
7
/8
(910)
33 (838)
5
1
/2
(140)
3
1
/8
(79)
COIL
FAN
Refrigeration
Outlet
59
3
/4 (1517)
11
3
/4 (299)
68
7
/8 (1747)
80
5
/8 (2046)
3
1
/4 (82)
1
1
/2 (37)
4 (101)
FWG
15
7
/8
(404)
24
3
/8
(618)
9
7
/8
(251)
Case-to-Case
Connection
Impact
Excel
FWG
Low / Medium Temperature
Wide Island Display with Glass Walls
Dimensions shown as inches & (mm).
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.