Hussmann FWEG Specifications

E
G
C
A
B
F
H
I
D
PN0465903E
FWEG
P/N 0465903_E
NSF
®
Certified
November 2009
Item Part # Description Wiring Item #
F
AN ASSEMBLIES, AND THERMOSTATS
A. 4W Standard Fan Assembly (1)
0392457 Fan Motor, Evaporator
(MO.4410101)
0464847 Fan Blade (FB.4780649) 4W Energy Efficient Fan Assembly (1) 0477653 Fan Motor, Evaporator
(MO.4410544)
0464847 Fan Blade (FB.4780649)
B. Optional Adjustable Refrigeration Thermostat (2)
C. 0398557 Defrost Termination Thermostat (3)
(Electric Defrost only) (CT.4440611)
D. 0481370 Heater Switch (4)
(Koolgas Defrost only) (CT.4440738)
Item Part # Description Wiring Item #
HEATERS
E. 208V Evaporator Defrost Heaters (5)
0444057 End case (HE.4850620)
F. 208V Drip Pan Defrost Heaters, Electric (6)
0444300 End case (HE.4850609)
120V Drip Pan Defrost Heaters, Koolgas (7) 0465906 End case (HE.4850628)
G. Nosing Anti-sweat Heaters (8)
0495006 End case (HE.4850684)
H. Return Grille Anti-sweat Heaters (9)
0495010 End case (HE.4850688)
I. Return Glass Anti-sweat Heaters (10)
0474775 End case, Front (GL.4977903) 0474776 End case, Left Side (GL.4978388) 0474777 End case, Right Side (GL.4977997)
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
©2008 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
Note: Revision D updates the Heater Switch part number on Page 1 and adds capacity and weight (Page 5).
2 of 7 FWEG Technical Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
8 1/2 (217)
4 3/4 (120)
FRONT
Refrigeration
Outlet
26 1/4 (665)
30 1/4 (767)
33 1/2 (851)
Waste
Outlet
Splashguard
Waste
Outlet
80 5/8 (2048)
65 (1653)
42
(1064)
31 5/8
(804)
49 7/8
(1267)
4 1/4 (108) 8 1/2 (217)
10 3/8
(263)
15 1/2
(393)
18 1/2 (470)
Wireway
24
(612)
Electrical
Stub Up Area
6 x 16
(152 x 406)
69 (1755)
26 1/2
(673)
52 3/8 (1330)
Electrical Field Connection
11 1/8 (283)
Engineering
Plan Views
Dimensions shown as inches & (mm).
10-2004
End Case
General
Case Length — Outside 80 5/
8 (2048)
Inside Length 73
5
/8 (1870) Maximum O/S dimension of case back to front (includes bumper) 42 (1064) Back of case to front of splashguard 33 1/
2 (851)
Back of case to O/S edge of front leg 30
1
/4 (767) Distance between edges of external legs and center legs 48 1/2 (1234) Distance between edges of center legs NA Distance between front legs and splashguard 3 1/8 (82)
Electrical Service (Electrical Field Wiring connection point)
RH End of case to center of stub up area 52 3/8 (1653) Back of case to center of stub up area 24 (612) Length of electrical wireway 26 1/2 (673) RH End of case to LH end of wireway 69 (1755)
Waste Outlets (One each end)
RH End of case to the center of LH waste outlet 65 (1653) RH End of case to the center of RH waste outlet 15 1/
2 (393)
Back O/S of case to center of waste outlets 31
5
/8 (804) Schedule 40 PVC drip pipe 1 1/
4 (32)
Refrigeration Outlet
Back of case to center of refrigeration outlet 26
1
/
4 (665)
RH end of case to center of refrigeration outlet 18
1
/
2 (470)
Low / Medium Temperature
Wide Island End Case
Wireway
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/4 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
5
/8
3 of 7P/N 0465903_E
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
FAN
COIL
42 (1064)
15 7/8
(404)
35 7/8 (910)
33 3/8 (848)
5 1/2
(140)
3 1/8 (79)
24 3/8 (618)
26 1/4 (665)
19 7/8 (503)
31 5/8 (804)
33 1/2 (851)
FWEG
9 7/8
(251)
30 1/4 (767)
35 1/4
(893)
Case-to-Case Connection
Refrigeration Outlet
Impact
Excel
FWEG
Low / Medium Temperature
Single Level End Display with Glass Front
Dimensions shown as inches & (mm).
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.
REFRIGERATION DATA
Note: This data is based on store temperature and
humidity that does not exceed 75°F and 55% R.H.
MED FF IC
Discharge Air (°F) +24 –12 –22
Evaporator (°F) +19 –20 –30
Unit Sizing (°F) +17 –23 –33
Btu/hr/case
MED FF IC
Parallel 1610
2560 2730
Conventional 1680
2670 2850
Optional energy efficient motors reduce the refrigeration
load by 55 Btu/hr/case.
DEFROST DATA
M
ED FF IC
Frequency (hr) 24 24 24
Defrost Water (lb/case/day) 6.6 6.3 5.4
(± 15% based on case configuration and product
loading).
E
LECTRIC
M
ED FF IC
Temp Term (°F) 48 48 48
Failsafe (minutes) 60 60 60
GAS
Duration (minutes) NA 15 18
O
FFTIME Not Recommended
Standard Defrost Thermostat
Close on rise: close 48°F — open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control — CI/CO *
M
ED
+22°F / +10°F
FF –17°F / –29°F
IC –27°F / –39°F
Indoor Unit Only, Pressure Defrost Termination*
Not Recommended *Use a Temperature Pressure Chart to determine PSIG conversions.
Estimated Charge (lb)**
End 1.5
**This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound.
Length Added to Lineup: 42 (1064)
This End Case is used in place of an End
Assembly. Partitions do not apply.
Loading...
+ 4 hidden pages