Hussmann FWE Specifications

G
E
D
C
B
A
F
PN0465902E
FWE
Technical Data Sheet
NSF
®
Certified
November 2009
Item Part # Description Wiring Item #
FAN ASSEMBLIES, AND THERMOSTATS
A. 4W Standard Fan Assembly (1)
0392457 Fan Motor, Evaporator
(MO.4410101)
0464847 Fan Blade (FB.4780649) 4W Energy Efficient Fan Assembly (1) 0477653 Fan Motor, Evaporator
(MO.4410544)
0464847 Fan Blade (FB.4780649)
B. Optional Adjustable Refrigeration Thermostat (2)
C. 0398557 Defrost Termination Thermostat (3)
(Electric Defrost only) (CT.4440611)
D. 0481370 Heater Switch (4)
(Koolgas Defrost only) (CT.4440738)
Item Part # Description Wiring Item #
H
EATERS
E. 208V Evaporator Defrost Heaters (5)
0444057 End case (HE.4850620)
F. 208V Drip Pan Defrost Heaters, Electric (6)
0444300 End case (HE.4850609)
120V Drip Pan Defrost Heaters, Koolgas (7) 0465906 End case (HE.4850628)
G. Nosing Anti-sweat Heaters (8)
0495006 End case (HE.4850684)
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
©2009 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
Note: Revision E adds Btu note, Page 3.
2 of 7 FWE Technical Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
8 1/2 (217)
4 3/4 (120)
FRONT
Refrigeration
Outlet
26 1/4 (665)
30 1/4 (767)
33 1/2 (851)
Waste
Outlet
Splashguard
Waste
Outlet
80 5/8 (2048)
65 (1653)
42
(1064)
31 5/8
(804)
49 7/8
(1267)
4 1/4 (108) 8 1/2 (217)
10 3/8
(263)
15 1/2
(393)
18 1/2 (470)
Wireway
24
(612)
Electrical
Stub Up Area
6 x 16
(152 x 406)
69 (1755)
26 1/2
(673)
52 3/8 (1330)
Electrical Field Connection
11 1/8 (283)
Engineering
Plan Views
Dimensions shown as inches & (mm).
End Case
General
Case Length — Outside 80 5/
8 (2048)
Inside Length 73
5
/
8 (1870)
Maximum O/S dimension of case back to front
(includes bumper) 42 (1064)
Back of case to front of splashguard 33 1/2 (851) Back of case to O/S edge of front leg 30 1/
4 (767)
Distance between edges of external legs and center legs 48
1
/2 (1234) Distance between edges of center legs NA Distance between front legs and splashguard 3 1/8 (82)
Electrical Service (Electrical Field Wiring connection point)
RH End of case to center of stub up area 52 3/8 (1653) Back of case to center of stub up area 24 (612) Length of electrical wireway 26 1/
2 (673)
RH End of case to LH end of wireway 69 (1755)
Waste Outlets (One each end)
RH End of case to the center of LH waste outlet 65 (1653) RH End of case to the center of RH waste outlet 15
1
/2 (393)
Back O/S of case to center of waste outlets 31 5/
8 (804)
Schedule 40 PVC drip pipe 1
1
/4 (32)
Refrigeration Outlet
Back of case to center of refrigeration outlet 26 1/4 (665) RH end of case to center of refrigeration outlet 18 1/
2 (470)
Low / Medium Temperature
Wide Island End case
Wireway
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/4 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
5
/8
10-2004
3 of 7P/N 0465902_E
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
FAN
COIL
15 1/4 (388)
35 7/8 (910)
33 3/8 (848)
5
1
/2
(140)
3 1/8 (79)
26 3/8 (669)
26 1/4 (665)
19 7/8 (503)
FWE
42 (1064)
31 5/8 (804)
33 1/2 (851)
30 1/4 (767)
35 1/4
(893)
Case-to-Case Connection
Refrigeration Outlet
Impact
Excel
FWE
Low / Medium Temperature
Single Level End Display with Solid Front
Dimensions shown as inches & (mm).
REFRIGERATION DATA
Note: This data is based on store temperature and
humidity that does not exceed 75°F and 55% R.H.
M
ED FF IC
Discharge Air (°F) +24 –12 –22
Evaporator (°F) +19 –20 –30
Unit Sizing (°F) +17 –23 –33
Btu/hr/case
MED FF IC
Parallel 1370
2175 2325
Conventional 1430
2270 2425
Optional energy efficient motors reduce the refrigeration
load by 55 Btu/hr/case.
DEFROST DATA
MED FF IC
Frequency (hr) 24 24 24
Defrost Water (lb/case/day) 4.8 4.5 3.6
(± 15% based on case configuration and product
loading).
ELECTRIC MED FF IC
Temp Term (°F) 48 48 48
Failsafe (minutes) 60 60 60
G
AS
Duration (minutes) NA 15 18
O
FFTIME Not Recommended
Standard Defrost Thermostat
Close on rise: close 48°F — open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control — CI/CO *
M
ED +22°F / +10°F
FF –17°F / –29°F
IC –27°F / –39°F
Indoor Unit Only, Pressure Defrost Termination*
Not Recommended *Use a Temperature Pressure Chart to determine PSIG conversions.
Estimated Charge (lb)**
End 1.5
**This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound.
Length Added to Lineup: 42 (1064)
This End Case is used in place of an End
Assembly. Partitions do not apply.
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.