5
Specialty Products
FMSS-L
FMSS-L
Technical Data Sheet
REFRIGERATION DATA
Note: This data is based on store temperature and
humidity that does not exceed 75F and 55% R.H.
Discharge Air (F) -5
Evaporator (F) 20
ote: Not recommended to control temp by regulating
coil temp allow t-stat to cycle and control temp.
tu/hr/ft*
Parallel 800
Conventional 920
*For all refrigeration equipment other than Hussmann,
use conventional Btu values.
DEFROST DATA
Frequency Hrs 6
OFFTIME
Temp Term °F 54
Failsafe Minutes 26
ELECTRIC or GAS Not Recommended
Engineering
CROSS SECTION
These merchandi s ers ar e man ufactured to meet ANSI/Nat i onal Sanitation
Foundation Standard #7 requirements.
We reserve the right to change or revise specifications and
roduct design in connection with any feature of our
roducts. Such changes do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for equipment previously sold or shipped.
Merchandiser Drip Pipe (in.) 1 ½*
Merchandiser Liquid Line (in.) 3/8*
Merchandiser Suction Line (in.) 5/8*
Estimated Charge (lb)***
*Dependent on case length and refrigerant type.
*** This is an average for all refrigerants types. Actual
refrigerant charge may vary by approximately half a
ound.
GPM PSI
NA NA
NA NA
NA NA
PHYSICAL DATA
4ft 1.2
5ft 1.5
6ft 1.8
GLYCOL REQUIREMENTS
CUL Listed
UL Sanitation
1 of 5
Rev A

5
Specialty Products
FMSS-L
Engineering
PLAN VIEW
These merchandi s ers ar e man ufactured to meet ANSI/Nat i onal Sanitation
Foundation Standard #7 requirements.
We reserve the right to change or revise specifications and
roduct design in connection with any feature of our
roducts. Such changes do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for equipment previously sold or shipped.
FMSS-L
Technical Data Sheet
Rev A
CUL Listed
UL Sanitation
2 of 5

5
Specialty Products
FMSS-L
FMSS-L
Technical Data Sheet
Rev A
CIRCUIT #1
LOADING
208 V 240 V
11.4
L1
9.6
L2
L3
12.9
11.1
SOLENOID VALVE
225-01-3206
CANOPY LIG H TING
(2) FP28T5/830
125-03-1131
LOW TEMP
THERMOSTAT
A19AGD-21
225-01-0707
MEDIUM TEMP
THERMOSTAT
A19AGD-21
225-01-0707
LIGHT
TOGGLE
SWITCH
BALLAST 125-01-3266
FULHAM LH3-120-L
TEMPERATURE
TOGGLE
SWITCH
~ 120VAC
G N L
50/60Hz.
RELAY MARS
90249Q
225-01-2045
RELAY MARS
90249Q
225-01-2045
5
2
2
6
3
1
5
2
6
3
1
RELAY MARS 90341
COIL: ~110/120VAC
(2)125-01-1343
KLIXON™ THERMODISK
20420L15-913-302
L20-1.5
D
Defrost
120 V
00003382
C
Refrig
120 V
EVAP FAN MOTORS
(2) 3 1/2" AXIAL FANS
EBM-PAPST 3306
00001212A
0.12 AMPS @ 115V
MM
35
6
2
4
1
L1 L2
~208/~240VAC -50/60Hz.
TO DEFROST CONTROL PANEL
CONDUCTIVE GLASS HEATER
20 W/FT @ 120VAC (80W .67A)
ANTI SWEAT HEATER
10 W/FT @ 120VAC (40W .33A)
125-01-0767
DEFROST HEATERS (24" FINNED)
(1) 2000W 9.6A @ 208VAC
00000260
RELAY OMRON
G7L-2A-TUBJ-CB-120A
125-01-3182
1
2356
1
0
4
8
6
4
2
4 of 5
6/19/07
FMSS-L CASE
4' DUAL TEMP FMSS-L CASE
W1400017
1
1