Hussmann FMSS-L Technical Data Sheet

Page 1
5
N
B
p
p
p
Specialty Products
FMSS-L
FMSS-L
Technical Data Sheet
REFRIGERATION DATA
Note: This data is based on store temperature and humidity that does not exceed 75F and 55% R.H.
Discharge Air (F) -5 Evaporator (F) 20
ote: Not recommended to control temp by regulating
coil temp allow t-stat to cycle and control temp.
tu/hr/ft*
Parallel 800
Conventional 920
*For all refrigeration equipment other than Hussmann, use conventional Btu values.
DEFROST DATA
Frequency Hrs 6
OFFTIME Temp Term °F 54 Failsafe Minutes 26
ELECTRIC or GAS Not Recommended
Engineering
CROSS SECTION
These merchandi s ers ar e man ufactured to meet ANSI/Nat i onal Sanitation Foundation Standard #7 requirements.
We reserve the right to change or revise specifications and
roduct design in connection with any feature of our
roducts. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
Merchandiser Drip Pipe (in.) 1 ½* Merchandiser Liquid Line (in.) 3/8* Merchandiser Suction Line (in.) 5/8*
Estimated Charge (lb)***
*Dependent on case length and refrigerant type.
*** This is an average for all refrigerants types. Actual refrigerant charge may vary by approximately half a
ound.
GPM PSI NA NA NA NA NA NA
PHYSICAL DATA
4ft 1.2 5ft 1.5 6ft 1.8
GLYCOL REQUIREMENTS
CUL Listed
UL Sanitation
1 of 5
Rev A
Page 2
5
p
p
Specialty Products
FMSS-L
Engineering
PLAN VIEW
These merchandi s ers ar e man ufactured to meet ANSI/Nat i onal Sanitation Foundation Standard #7 requirements.
We reserve the right to change or revise specifications and
roduct design in connection with any feature of our
roducts. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
FMSS-L
Technical Data Sheet
Rev A
CUL Listed
UL Sanitation
2 of 5
Page 3
5
Specialty Products
FMSS-L
FMSS-L
Technical Data Sheet
Rev A
3 of 5
Page 4
5
Specialty Products
FMSS-L
FMSS-L
Technical Data Sheet
Rev A
CIRCUIT #1
LOADING
208 V 240 V
11.4
L1
9.6
L2 L3
12.9
11.1
SOLENOID VALVE 225-01-3206
CANOPY LIG H TING (2) FP28T5/830 125-03-1131
LOW TEMP THERMOSTAT A19AGD-21 225-01-0707
MEDIUM TEMP THERMOSTAT A19AGD-21 225-01-0707
LIGHT TOGGLE SWITCH
BALLAST 125-01-3266
FULHAM LH3-120-L
TEMPERATURE TOGGLE SWITCH
~ 120VAC
G N L
50/60Hz.
RELAY MARS 90249Q 225-01-2045
RELAY MARS 90249Q 225-01-2045
5
2
2
6
3
1
5
2
6
3
1
RELAY MARS 90341 COIL: ~110/120VAC (2)125-01-1343
KLIXON™ THERMODISK 20420L15-913-302 L20-1.5
D
Defrost
120 V
00003382
C Refrig 120 V
EVAP FAN MOTORS (2) 3 1/2" AXIAL FANS EBM-PAPST 3306 00001212A
0.12 AMPS @ 115V
MM
35
6
2
4
1
L1 L2 ~208/~240VAC -50/60Hz.
TO DEFROST CONTROL PANEL
CONDUCTIVE GLASS HEATER 20 W/FT @ 120VAC (80W .67A)
ANTI SWEAT HEATER 10 W/FT @ 120VAC (40W .33A) 125-01-0767
DEFROST HEATERS (24" FINNED) (1) 2000W 9.6A @ 208VAC 00000260
RELAY OMRON G7L-2A-TUBJ-CB-120A
125-01-3182
1
2356
1
0
4
8
6
4
2
4 of 5
6/19/07
FMSS-L CASE
4' DUAL TEMP FMSS-L CASE
W1400017
1
1
Page 5
5
Specialty Products
FMSS-L
FMSS-L
Technical Data Sheet
Rev A
5 of 5
Loading...