Hussmann FL4NX-EP Specifications

Item Part # Description Wiring Item #
F
AN ASSEMBLIES
4 Ft, 8 Ft & 12 Ft
A. 12W Standard Fan Assembly (1)
0047000 Fan Motor, Evaporator
(MO.4410103)
0461805 Fan Blade (FB.4780446) 12W Energy Efficient Fan Assembly (1) 0477655 Fan Motor, Evaporator
(MO.4410546)
0461805 Fan Blade (FB.4780446)
6 Ft Only
A. 7W Standard Fan Assembly (1)
0058698 Fan Motor, Evaporator
(MO.4410102)
0142780 Fan Blade (FB.0142780) 7W Energy Efficient Fan Assembly (1) 0477654 Fan Motor, Evaporator
(MO.4410545)
0142780 Fan Blade (FB.0142780)
Item Part # Description Wiring Item #
THERMOSTATS
B. Optional Adjustable Refrigeration Thermostat (2)
L
AMPS AND BALLASTS
C. Ballast, Electronic (3)
0480130 2 lamps (BA.4481676) 0480131 3 lamps (BA.4481654) 0480132 4 lamps (BA.4481677)
D. Fluorescent Lamp (4)
Replace with like fixtures
LED F
IXTURES AND POWER SUPPLY
E. 0501213 Power Supply (EP.4481861) (5)
F. LED Canopy Fixture (6)
Replace with like fixtures — See Page 5.
G. LED Shelf Fixture (7)
Replace with like fixtures — See Page 5.
C
B
D
C
D
A
F
E
G
P/N_0496537_F
FL4NX-EP
Technical Data Sheet
P/N 0496537_F
March 2010
©2010 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
Note: Revision F updates EcoShine values on page 4, LED parts on page 5, and canopy wiring diagram on page 6.
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
Wireway
Splashguard
26 3/4
(680)
25 1/4
(641)
37
(940)
A
41 1/2
(1054)
28 1/2
(724)
3 In.
(77 mm)
Required
Air Gap
Refrigeration
Outlet
Waste Outlet
Waste Outlet
FRONT
4 3/4 (120)
21 1/4
(540)
D
C
8 (203)
12 1/8 (307)
4 1/4 (108)
41 1/2
(1054)
43 7/8
(1114)
B
19
(483)
NOTE: Case-to-Case Electrical Connections are made IN FRONT OF SPLASHGUARD.
Electrical
Stub Up Area
6 x 6
(152x152)
Electrical Field Connection
26 1/2
(673)
4 3/4 (120)
4 1/2 (115)
FL4NX
2 of 9 FL4NX-EP Technical Data Sheet
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
Engineering
Plan Views
Dimensions shown as in. and (mm).
Narrow Floral
10-2004
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/4 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
7
/8
4 ft 6 ft 8 ft 12 ft
General
(A) Case Length (without ends or partitions) 48 3/8
(1229) 72
3
/8
(1838) 96
3
/8
(2448) 144
1
/2
(3670)
(Each end and insulated partition adds 1 1/2 in. (38 mm) to case line up.)
Maximum O/S dimension of case back to front
(includes bumper) 37 (940) 37 (940) 37 (940) 37 (940)
Back of case to front of splashguard 28 1/2 (724) 28 1/2 (724) 28 1/2 (724) 28 1/2 (724) Back of case to O/S edge of front leg 25 1/4 (641) 25 1/4 (641) 25 1/4 (641) 25 1/4 (641) Distance between edges of external legs and center legs NA 29 1/2 (750) 41 1/2 (1054) 41 1/2 (1054) Distance between edges of center legs NA NA NA 43 7/8 (1114) Distance between front legs and splashguard 2 3/4 (70) 2 3/4 (70) 2 3/4 (70) 2 3/4 (70)
Electrical Service (Electrical Field Wiring connection point)
(B) RH End of case to center of stub up area 36 1/4 (921) 60 1/4 (1530) 84 1/4 (2140) 132 3/8 (3363)
Back of case to center of stub up area 19 (483) 19 (483) 19 (483) 19 (483) Length of electrical wireway 26 1/2 (673) 26 1/2 (673) 26 1/2 (673) 26 1/2 (673)
(C) RH End of case to LH end of wireway 42 1/8 (1070) 66 1/8 (1680) 90 1/8 (2289) 138 1/4 (3511)
Waste Outlets (One each end)
(D) RH End of case to the center of LH waste outlet 36
1
/4
(921) 60
1
/4
(1530) 84
1
/4
(2140) 132
3
/8
(3363)
RH End of case to the center of RH waste outlet 12
1
/8 (307) 12 1/8 (307) 12 1/8 (307) 12 1/8 (307) Back O/S of case to center of waste outlets 26 3/4 (680) 26 3/4 (680) 26 3/4 (680) 26 3/4 (680) Schedule 40 PVC drip pipe 1 1/4 (32) 1 1/4 (32) 1 1/4 (32) 1 1/4 (32)
Refrigeration Outlet
Back of case to center of refrigeration outlet 21 1/4 (540) 21 1/4 (540) 21 1/4 (540) 21 1/4 (540) RH end of case to center of refrigeration outlet 8 (203) 8 (203) 8 (203) 8 (203)
Wireway
REFRIGERATION DATA
Note: This data is based on store temperature and humidity that does not exceed 75°F and 55% R.H.
FL4NX-EP UNLIT
Discharge Air °F 34
Evaporator °F 27
Unit Sizing °F 25
Btu/hr/ft
— Unlit Shelves
‡‡
FL4NX-EP Parallel Conventional
U
NLIT 1200 1250
Optional energy efficient motors reduce the
refrigeration load by 27 Btu/hr/ft.
‡‡
Add 10 Btu/hr/ft per shelf row for LED fixtures.
Add 20 Btu/hr/ft per shelf row for fluorescent lamps.
DEFROST DATA
Frequency Hr 8
Defrost Water (lb/ft/day) 3.5
(± 15% based on case configuration and product
loading).
OFFTIME FL4NX-EP
Time (minutes) 20
ELECTRIC OR GAS Not Recommended
CONVENTIONAL CONTROLS
Low Pressure Backup Control
CI/CO* FL4NX-EP
18°F / 8°F
Indoor Unit Only, Pressure Defrost
Termination* 48°F
*Use a Temperature Pressure Chart to determine PSIG conversions.
Estimated Charge** FL4NX-EP
4 ft 1.6 lb 26 oz 0.7 kg
6 ft 2.2 lb 35 oz 1.0 kg
8 ft 3.1 lb 50 oz 1.4 kg
12 ft 4.5 lb 72 oz 2.0 kg
***This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound.
3 of 9
P/N 0496537_F
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
4 3/4 (120)
26 3/4 (680)
25 1/4 (641)
37 (940)
28 1/2 (724)
25 3/8
(644)
34 5/8
(878)
FAN
C
O
I
L
FL4NX-EP
21 1/4
(540)
3 In. (77 mm)
Required
Air Gap
67 1/8
(1705)
7 1/4 (183)
23 5/8
(600)
3 5/8
(92)
21 1/4 (540)
Refrigeration
Outlet
6
(152)
Electrical
Case to Case
Connections
46 1/4
(1174)
36 1/8
(918)
Dimensions shown as in. and (mm).
Narrow Footprint, Multi-deck, 4 Display Levels, Standard Front Height
Impact
Excel
FL4NX-EP