Hussmann FL3X-LEP Specifications

P/N_0505002_D
A
B
C
D
C
D
F
E
G
FL3X-LEP
Technical Data Sheet
March 2010
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
Item Part # Description Wiring Item #
F
AN ASSEMBLIES
4 Ft, 8 Ft & 12 Ft
A. 7W Standard Fan Assembly (1)
0058698 Fan Motor, Evaporator
(MO.4410102)
0142780 Fan Blade (FB.0142780) 7W Energy Efficient Fan Assembly (1) 0477654 Fan Motor, Evaporator
(MO.4410545)
0142780 Fan Blade (FB.0142780)
6 Ft Only
A. 4W Standard Fan Assembly (1)
0392457 Fan Motor, Evaporator
(MO.4410101)
0382383 Fan Blade (FB.4780617) 4W Energy Efficient Fan Assembly (1) 0477653 Fan Motor, Evaporator
(MO.4410544)
0382383 Fan Blade (FB.4780617)
Item Part # Description Wiring Item #
T
HERMOSTATS
B. Optional Adjustable Refrigeration Thermostat (2)
L
AMPS AND BALLASTS
C. Ballast, Electronic (3)
0480130 2 lamps (BA.4481676) 0480131 3 lamps (BA.4481654) 0480132 4 lamps (BA.4481677)
D. Fluorescent Lamp (4)
Replace with like fixtures
LED F
IXTURES AND POWER SUPPLY
E. 0501213 Power Supply (EP.4481861) (5)
F. LED Canopy Fixture (6)
Replace with like fixtures — See Page 5.
G. LED Shelf Fixture (7)
Replace with like fixtures — See Page 5.
©2010 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
Note: Revision F updates EcoShine values on page 4, LED parts on page 5, and canopy wiring diagram on page 6.
2 of 9 FL3X-LEP Technical Data Sheet
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
Engineering
Plan Views
Floral
06-2008
NOTE: Case-to-Case Electrical Connections are made IN FRONT OF SPLASHGUARD.
4 3/4 (120)
Splashguard
31 5/8
(804)
42
(1064)
A
41 1/2
(1054)
3 In.
(77 mm)
Required
Air Gap
Refrigeration
Outlet
Electrical
Stub Up Area
6 x 6
(152x152)
Waste Outlet
Waste Outlet
FRONT
26 1/4
(665)
B
D
8 (203)
4 1/2 (115)
12 1/8 (307)
41 1/2
(1054)
43 7/8
(1114)
C
Wireway
4 3/4 (120)
26 1/2
(673)
4 1/4 (108)
24
(612)
33 1/2
(851)
Electrical Field Connection
30 1/4
(768)
FL3X
4 ft 6 ft 8 ft 12 ft
General
(A) Case Length (without ends or partitions) 48 3/8
(1229) 72
3
/8
(1838) 96
3
/8
(2448) 144
1
/2
(3670)
(Each end and insulated partition adds 1 1/2 in. (38 mm) to case line up.)
Maximum O/S dimension of case back to front
(includes bumper) 42 (1064) 42 (1064) 42 (1064) 42 (1064)
Back of case to O/S edge of front leg 30 1/4 (768) 30 1/4 (768) 30 1/4 (768) 30 1/4 (768) Distance between edges of external legs and center legs NA 29 1/2 (750) 41 1/2 (1054) 41 1/2 (1054) Distance between edges of center legs NA NA NA 43 7/8
(1114)
Electrical Service (Electrical Field Wiring connection point)
(B) RH End of case to center of stub up area 36
1
/4 (921) 60 1/4 (1530) 84 1/4 (2140) 132 3/8 (3363) Back of case to center of stub up area 24 (612) 24 (612) 24 (612) 24 (612) Length of electrical wireway 26 1/2 (673) 26 1/2 (673) 26 1/2 (673) 26 1/2 (673)
(C) RH End of case to LH end of wireway 42 1/8 (1070) 66 1/8 (1680) 90 1/8 (2289) 138 1/4 (3511)
Waste Outlets (One each end)
(D) RH End of case to the center of LH waste outlet 36 1/4 (921) 60 1/4 (1530) 84 1/4 (2140) 132 3/8 (3363)
RH End of case to the center of RH waste outlet 12
1
/8
(307) 12
1
/8
(307) 12
1
/8
(307) 12
1
/8
(307)
Back O/S of case to center of waste outlets 31
5
/8 (804) 31 5/8 (804) 31 5/8 (804) 31 5/8 (804) Schedule 40 PVC drip pipe 1 1/4 (32) 1 1/4 (32) 1 1/4 (32) 1 1/4 (32)
Refrigeration Outlet
Back of case to center of refrigeration outlet 26 1/4 (665) 26 1/4 (665) 26 1/4 (665) 26 1/4 (665) RH end of case to center of refrigeration outlet 8 (203) 8 (203) 8 (203) 8 (203)
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/4 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
7
/8
Wireway
Dimensions shown as inches and (mm).
REFRIGERATION DATA
Note: This data is based on store temperature and
humidity that does not exceed 75°F and 55% R.H.
FL3X-LEP UNLIT
Discharge Air °F 32
Evaporator °F 28
Unit Sizing °F 26
Btu/hr/ft
— Unlit Shelves
‡‡
FL3X-LEP‡‡Parallel Conventional
U
NLIT 950 1015
Optional energy efficient motors reduce the
refrigeration load by 21 Btu/hr/ft.
‡‡
Add 10 Btu/hr/ft per shelf row for LED fixtures.
Add 20 Btu/hr/ft per shelf row for fluorescent lamps.
DEFROST DATA
FL3X-LEP
Frequency (hr) 8
Defrost Water (lb/ft/day) 6
(±15% based on case configuration and product loading.
O
FFTIME FL3X-LEP
Time (minutes) 30
E
LECTRIC OR GAS Not Recommended
CONVENTIONAL CONTROLS
Low Pressure Backup Control
FL3X-LEP
CI/CO* 19°F / 9°F
Indoor Unit Only,
Pressure Defrost Termination* 48°F
*Use a Temperature Pressure Chart to determine PSIG conversions.
Estimated Charge** FL3X-EP
4 ft 1.4 lb 22 oz 0.6 kg
6 ft 1.9 lb 30 oz 0.9 kg
8 ft 2.7 lb 43 oz 1.2 kg
12 ft 3.9 lb 62 oz 1.8 kg
***This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound.
P/N 0505002_D 3 of 9
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
31 5/8 (804)
4 3/4 (120)
30 1/4 (768)
42 (1064)
33 1/2 (851)
FL3X-LEP
30 1/4
(768)
42 1/8
(1070)
34 5/8
(879)
FAN
17 1/4
(438)
3 In.
(77 mm)
Required
Air Gap
63 1/8
(1603)
7 1/4 (183)
19 5/8
(499)
3 5/8
(92)
26 1/4 (665)
Refrigeration Outlet
6
(152)
Electrical
Case to Case
Connections
C O
I
L
36 1/2
(927)
Impact
Excel
FL3X-LEP
Floral
Multi-deck, 2 Display Levels
Dimensions shown as inches and (mm).
Loading...