Technical Data Sheet
P/N 0465897_E
NSF
®
Certified
November 2010
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
©2010 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
Note: Revision E adds 6-ft model
P/N_0465897_E
Item Part # Description Wiring Item #
FAN ASSEMBLIES, AND THERMOSTATS
A. 4W Standard Fan Assembly (1)
0392457 Fan Motor, Evaporator
(MO.4410101)
0382383 Fan Blade (FB.4780617) 4W Energy Efficient Fan Assembly (1) 0477653 Fan Motor, Evaporator
(MO.4410544)
0382383 Fan Blade (FB.4780617)
B. Optional Adjustable Refrigeration Thermostat (2)
(Electric Defrost only) (CT.4440611)
D. 0481370 Heater Switch (4)
(Koolgas Defrost only) (CT.4440738)
H
EATERS
E. 208V Evaporator Defrost Heaters (5)
0444057 6 ft case (HE.4850620) 0465916 8 ft case (HE.4850630) 0465915 12 ft case (HE.4850631)
Item Part # Description Wiring Item #
HEATERS (CONTINUED)
F. 208V Drip Pan Defrost Heaters, Electric (6)
0444300 6 ft case (HE.4850609) 0462160 8 ft case (HE.4850636) 0444296 12 ft case (HE.4850572)
120V Drip Pan Defrost Heaters, Koolgas (7)
0465906 6 ft case (HE.4850628) 0465907 8 ft case (HE.4850622) 0465908 12 ft case (HE.4850623)
G. Nosing Anti-sweat Heaters (8)
0495006 6 ft case (HE.4850684) 0495007 8 ft case (HE.4850685) 0495008 12 ft case (HE.4850686)
H. Return Grille Anti-sweat Heaters (9)
0495010 6 ft case (HE.4850688) 0495011 8 ft case (HE.4850689) 0495012 12 ft case (HE.4850690)
I. Return Glass Anti-sweat Heaters (10)
0489808 6 ft case (GL.4967587) 0474778 8 ft case (GL.4987838) 0474779 12 ft case (GL.4987839)
J. Discharge Glass Anti-sweat Heaters (11)
0516069 6 ft case (GL.4996462) 0504300 8 ft case (GL.4969359) 0504342 12 ft case (GL.4990684)
2 of 7 FIG Technical Data Sheet
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
4 3/4 (120)
11 3/4
(299)
FRONT
12 1/8 (307)
Waste Outlet
Electrical Field Connection
A
B
C
D
46 1/4
(1175)
Splashguard
8 (203)
Refrigeration Outlet
Waste Outlet
39 7/8
(1013)
Electrical
Stub Up Area
6 x 6
(152 x 152)
26 1/2 (673)
NOTE: Case-to-Case Electrical Connections are made IN FRONT OF SPLASHGUARD.
41 1/2
(1054)
43 7/8
(1114)
41 1/2
(1054)
4 1/4 (108)
4 1/2 (115)
Wireway
Splashguard
8 1/2 (217)
8 1/2 (217)
58
(1471)
49 3/8
(1254)
47 5/8
(1209)
42 1/8
(1071)
FI / FIG
Engineering
Plan Views
Dimensions shown as inches & (mm).
6 ft 8 ft 12 ft
General
(A) Case Length (without ends or partitions) 73 3/4 (1874) 96 3/8 (2448) 144 1/2 (3670)
(Each end and insulated partition adds 2 in. (51 mm) to case line up.)
Maximum O/S dimension of case back to front (includes bumper) 58 (1471) 58 (1471) 58 (1471) Back of case to front of splashguard 49 3/8 (1254) 49 3/8 (1254) 49 3/8 (1254) Back of case to O/S edge of front leg 46 1/
4 (1175) 46
1
/
4 (1175) 46
1
/
4 (1175)
Distance between edges of external legs and center legs 41
1
/2 (1054) 41 1/2 (1054) 41 1/2 (1054) Distance between edges of center legs NA NA 43 7/8 (1114) Distance between front legs and splashguard 3 1/8 (82) 3 1/8 (82) 3 1/8 (82)
Electrical Service (Electrical Field Wiring connection point)
(B) RH End of case to center of stub up area 61 5/8 (1565) 84 1/4 (2141) 132 3/8 (3363)
Back of case to center of stub up area 39 7/8 (1013) 39 7/8 (1013) 39 7/8 (1013) Length of electrical wireway 26
1
/2 (673) 26 1/2 (673) 26 1/2 (673)
(C) RH End of case to LH end of wireway 90
1
/8 (2289) 90 1/8 (2289) 138 1/4 (3511)
Waste Outlets (One each end)
(D) RH End of case to the center of LH waste outlet 61 5/8 (1565) 84 1/4 (2141) 132 3/8 (3363)
RH End of case to the center of RH waste outlet 12 1/8 (307) 12 1/8 (307) 12 1/8 (307) Back O/S of case to center of waste outlets 47 5/
8 (1209) 47
5
/
8 (1209) 47
5
/
8 (1209)
Schedule 40 PVC drip pipe 1
1
/4 (32) 1 1/4 (32) 1 1/4 (32)
Refrigeration Outlet
Back of case to center of refrigeration outlet 42 1/8 (1071) 42 1/8 (1071) 42 1/8 (1071) RH end of case to center of refrigeration outlet 8 (203) 8 (203) 8 (203)
Intermediate Island
Frozen Food
Wireway
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/4 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
5
/8
REFRIGERATION DATA
Note: This data is based on store temperature and
humidity that does not exceed 75°F and 55% R.H.
FF
Discharge Air (°F) –12
Evaporator(°F) –20
Unit Sizing (°F) –23
Btu/hr/ft FF
Parallel
535
Conventional
560
DEFROST DATA
FF
Frequency (hr) 24
Defrost Water (lb/ft/day) 1.0
(± 15% based on case configuration and product
loading).
E
LECTRIC
FF
Temp Term (°F) 48
Failsafe (minutes) 60
GAS
Duration (minutes) 15
O
FFTIME Not Recommended
Standard Defrost Thermostat
Close on rise: close 48°F — open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control — CI/CO *
FF –17°F / –29°F
IC –27°F / –39°F
Indoor Unit Only, Pressure Defrost
Termination* Not Recommended
*Use a Temperature Pressure Chart to determine PSIG conversions.
Estimated Charge **
6 ft 2.1 lb 34 oz 1.0 kg
8 ft 2.5 lb 40 oz 1.1 kg
12 ft 3.7 lb 59 oz 1.7 kg
**This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound.
3 of 7P/N 0465897_E
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
FAN
COIL
15 7/8 (404)
47 7/8
(1218)
5
1
/2
(140)
42 1/8 (1071)
34 3/8 (873)
47 5/8 (1209)
49 3/8 (1254)
58 (1471)
46 1/4 (1175)
35 7/8
(910)
3 1/8 (79)
24 3/8 (618)
FIG
9 7/8
(251)
Refrigeration Outlet
Case-to-Case Connection
Impact
Excel
FIG
Frozen Food
Intermediate Island Display with Glass Walls
Dimensions shown as inches & (mm).
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.