Hussmann F6L Specifications

Item Part # Description Wiring Item #
FAN ASSEMBLIES, AND THERMOSTATS
A. 12W Standard Fan Assembly
0047000 Fan Motor, Evaporator (MO.4410311) (1) 0413031 Fan Blade (FB.4780620)
embossing toward motor
12W Energy Efficient Fan Assembly 0477655 Fan Motor, Evaporator (MO.4410546) (1) 0142780 Fan Blade (FB.0142780)
embossing toward motor
B. 0404551 Fan Motor – Muffin, Ambient (2)
C. 0440420 Fan Motor, Reversing Non-Refrigerated (3)
(Electric Defrost) 120V, 9W, CW (MO.4410302)
0141070 Fan Blade (FB.0141070)
embossing toward motor
0058698 Fan Motor, Non-Refrigerated (Gas Defrost) (3 )
120V, 7W, CW (MO.4410102)
0141070 Fan Blade (FB.0141070)
embossing toward motor
D. 0474130 Standard Non-Adjustable Bi-metal (4)
Electric Defrost Thermostat (CT.4440737)
0358566 Optional Non-Adjustable Bi-metal
Gas Defrost Thermostat (CT.0358566)
E. Optional Adjustable Refrigeration Thermostat (5)
ELECTRIC DEFROST HEATERS
F. 0123592 Relay, DPDT 208V coil (RL.4440495) (6) G. 0442232 Heater Limit Thermostat (CT.4481090) (7) H. Defrost Heater (8)
0487482 4, 8 & 12 ft (HE.4481533) 0495023 6 ft (HE.4850742)
Item Part # Description Wiring Item #
ELECTRIC DEFROST HEATERS (CONTINUED)
I. Defrost Heater (9)
0486060 4 ft (HE.4851042) 0486061 6 ft (HE.4850669) 0486062 8 ft (HE.4850692) 0486063 12 ft (HE.4850653)
ANTI-SWEAT HEATERS
J. Return Air Heater (10)
0486052 4 ft, (HE.4850701) 0486053 6 ft, (HE.4850702) 0486054 8 ft, (HE.4850627) 0486055 12 ft, (HE.4850660)
K. Main Anti-Sweat Heater (Honeycomb Divider) (11)
0494989 4 ft (HE.4850723) 0494990 6 ft (HE.4850724) 0494991 8 ft (HE.4850725) 0494992 12 ft (HE.4850726)
L. Optional Front Rail Heater (12)
0494998 4 ft (HE.4850727) 0494999 6 ft (HE.4850728) 0495000 8 ft (HE.4850729) 0495001 12 ft (HE.4850730)
LAMPS AND BALLASTS
M. Ballast, Electronic (13)
0466233 1 lamp (BA.4481300) 0466234 2 lamps (BA.4480823) 0466235 3 lamps (BA.4480901)
N. Fluorescent Lamp (14)
Replace with like fixtures
H
N
N
I
D
C
J
E
F
M
L
B
M
K
G
A
F6L
Technical Data Sheet
P/N 0518257_A
NSF
®
Certified
November 2010
P/N_0518257_A
©2010 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
2 of 13 F6L Technical Data Sheet
U.S. & Canada 1-800-922-1919 • Mexico 1-800-522-1900
B
Wireway
8 (203)
4
(102)
30 5/
8
(778)
Refrigeration
Outlet
A
46 1/2
(1182)
27 1/2
(699)
29 1/2
(749)
38 5/
8
(981)
Front
C
Waste Outlet
Water Seal
(See Note*)
D
35 3/8
(899)
Dimensions shown as inches & (mm).
Engineering
Plan Views
F6L
Frozen
06-2010
4 ft 6 ft 8 ft 12 ft
General
(A) Case Length (without ends or partitions) 48 1/4 (1226) 72 1/4 (1835) 96 3/8 (2448) 144 1/2 (3670)
NOTE: Each end or insulated partition adds 1
1
/
2 inch to lineup.
Maximum O/S dimension back to front (with bumper) 46 1/2 (1182) 46 1/2 (1182) 46 1/2 (1182) 46 1/2 (1182) Back of case to front of splashguard 38 5/8 (981) 38 5/8 (981) 38 5/8 (981) 38 5/8 (981) Width of skid rail 4 1/
8 (105) 4
1
/
8 (105) 4
1
/
8 (105) 4
1
/
8 (105)
RH end of case to outside edge of external support 1
3
/8 (35) 1 3/8 (35) 1 3/8 (35) 1 3/8 (35)
Distance between inside edges of
external support and center support NA 28 1/
2 (724) 40
1
/
2 (1029) 40
1
/
2 (1029)
Distance between inside edges of center supports NA NA NA 43
7
/8 (1114) Distance between inside edges of external supports 37 (940) NA NA NA Stub-up area between front skid rail and splashguard 8 (203) 8 (203) 8 (203) 8 (203)
Electrical Service (Electrical Field Wiring connection point)
(B) RH End of case to center of farthest knockout 40
1
/4 (1022) 64 1/4 (1632) 88 3/8 (2245) 138 7/8 (3527)
Back of case to center of end knockout 35 3/
8 (899) 35
3
/
8 (899) 35
3
/
8 (899) 35
3
/
8 (899)
Length of electrical wireway 34
5
/8 (879) 34 5/8 (879) 34 5/8 (879) 34 5/8 (879)
Waste Outlet
(C) RH End of case to the center of waste outlet 24
1
/8 (613) 48 1/8 (1222) 72 1/4 (1835) 72 1/4 (1835)
Back O/S of case to center of waste outlet 27 1/
2 (699) 27
1
/
2 (699) 27
1
/
2 (699) 27
1
/
2 (699)
Water Seal
Edge of water seal to center of waste outlet 4 (102) 4 (102) 4 (102) 4 (102) Schedule 40 diameter drip pipe 1
1
/2 (38) 1 1/2 (38) 1 1/2 (38) 1 1/2 (38)
(Field installed water seal outlets, tees, and connectors
are shipped with the merchandiser.)
Refrigeration Outlet
Back of case to center of refrigeration outlet 30
5
/8 (778) 30 5/8 (778) 30 5/8 (778) 30 5/8 (778)
(D) RH end of case to center of refrigeration outlet 9 (229) 9 (229) 9 (229) 9 (229)
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/2 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.) 1 1/8
3 of 13P/N 0518257_A
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Multi-Deck, 6 Display Levels
Excel F6L
Multi-Deck Frozen Food
REFRIGERATION DATA
Note: This data is based on store
temperature and humidity that does not exceed 75°F and 55% R.H.
F6L F6L*
Discharge Air (°F) –8 –3
Evaporator (°F) –16 –9
Unit Sizing (°F) –19 –12
Btu/hr/ft**
F6L F6L*
Parallel 1755 1660
Conventional 1850 1750
* = Non-0 Return Code
Optional energy efficient motors reduce the
refrigeration load by 55 Btu/hr/ft.
DEFROST DATA
F6L
Frequency (hr) 8 Defrost Water
(lb/ft/day)
8.6
(± 15% based on case configuration and product loading).
E
LECTRIC REVERSE
AIR DEFROST
Temp Term (°F) 60°
Failsafe (minutes) 30
G
AS DEFROST
Temp Term (°F) NA
Failsafe (minutes) 22
OFFTIME NA
CONVENTIONAL CONTROLS
Low Pressure Backup Control
F6L
CI/CO (Temp °F)
**
–20°/ –39°
Indoor Unit Only, Pressure Defrost Termination (Temp °F)
** 48°
**Use a Temperature Pressure Chart to determine PSIG conversions.
Estimated Charge *** F6L
4 ft 1.8 lb 29 oz 0.8 kg
6 ft 2.5 lb 40 oz 1.1 kg
8 ft 3.5 lb 56 oz 1.6 kg
12 ft 5.1 lb 82 oz 2.3 kg
***This is an average for all refrigerant
types. Actual refrigerant charge may vary by approximately 0.5 lb (8 oz / 0.2 kg).
C O
I
L
F6L
FAN
46 1/2 (1182)
45 5/8
(1159)
41/8
(101)
38 5/8 (981)
Refrigeration Outlet
29 1/2
(749)
30 5/8
(778)
27 1/2 (699)
7 5/8
(194)
35 3/8
(899)
23
(584)
7 1/2 (191)
81 1/4
(2064)
5 1/2
(139)
22
(559)
14
(355)
16
(406)
18
(457)
55 1/4
(1403)
49 5/8
(1260)
12
(305)
6
(152)
2
(51)
25 7/8
(657)
Optional
Bottom
Wire Rack
53
(1346)
Dimensions are shown as inches & (mm).
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.
4 of 13 F6L Technical Data Sheet
U.S. & Canada 1-800-922-1919 • Mexico 1-800-522-1900
Excel F6L
Multi-Deck Frozen Food
Electrical Data
Number of Fans 4 ft 6 ft 8 ft 12 ft
Main Evaporator 2 4 4 6 Ambient 1 2 2 3 Non-Refrigerated 1 2 2 3
Amperes Watts
4 ft 6 ft 8 ft 12 ft 4 ft 6 ft 8 ft 12 ft
Main Evaporator Fans (12W)
120V 60Hz Standard 1.30 2.60 2.60 3.90 100 200 200 300
120V 50Hz Standard 1.50 3.00 3.00 4.50 114 228 228 342
120V 60 Hz Energy Efficient 0.60 1.20 1.20 1.80 36 72 72 108
Ambient Fans (15W)
120V 60Hz Standard 0.25 0.50 0.50 0.75 22 44 44 66
120V 50Hz Standard 0.29 0.58 0.58 0.87 24 48 48 72
Non-Refrigerated Fan (9W, Reversing )
Standard Electric Defrost Only
120V 60Hz Standard 0.24 0.48 0.48 0.72 25 50 50 75
120V 50Hz Standard 0.27 0.54 0.54 0.81 28 56 56 84
Non-Refrigerated Fans (7W) Optional Gas Defrost Only
120V 60Hz Standard 0.50 1.00 1.00 1.50 39 78 78 117
120V 50Hz Standard 0.55 1.10 1.10 1.65 42 84 84 126
Anti-Sweat Heaters Constant On
Main Divider Anti-sweat Heaters 0.75 1.00 1.50 2.25 90 120 180 270
Return Grill Air Heaters 0.83 1.25 1.67 2.50 100 150 200 300
Minimum Circuit Ampacity Standard Electric Defrost
120V 60Hz Standard 3.57 6.03 6.95 10.32
120V 50Hz Standard 3.84 6.57 7.49 11.13
120V 60 Hz Energy Efficient 2.87 4.63 5.55 8.22
Minimum Circuit Ampacity Optional Gas Defrost
120V 60Hz Standard 3.83 6.55 7.47 11.10
120V 50Hz Standard 4.12 7.13 8.05 11.97
120V 60 Hz Energy Efficient 3.13 5.15 6.07 9.00
Optional Hand Rail Anti-Sweat Heater 120V 0.56 0.78 1.11 1.67 67 94 133 200
Maximum Over Current Protection 120V 20 20 20 20
Maximum Over Current Protection 230V NA
Electric Defrost Heaters 208V 1ph
Modular U-Shaped 3.29 4.76 6.58 9.87 685 990 1370 2055
Full Length Rod 4.71 7.07 9.42 14.15 980 1470 1960 2943
Total Defrost Heaters 8.00 11.83 16.00 24.02 1665 2460 3330 4998
Standard Lighting (T-8 fluorescent)
1 Row Canopy & 1 Row Rail 0.52 1.00 1.00 1.50 62 120 120 184
Optional Lighting (T-8 fluorescent)
2 Row Canopy & 1 Row Rail 0.76 1.50 150 2.25 92 180 180 231
5 of 13P/N 0518257_A
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Excel F6L
Multi-Deck Frozen Food
ESTIMATED SHIPPING WEIGHT
4
Case Solid End
4 ft 6 ft 8 ft 12 ft (each)
lb (kg) 1000 ( 454 ) 1300 ( 590 ) 1700 ( 771 ) 2000 ( 907 ) 100 ( 45 )
4
Actual weights will vary according to optional kits included.
Product Data
Recommended Usable Cube 1(Cu Ft/Ft) 7.73 ft3 /ft (0.72 m3 /m) AHRI Total Display Area 2(Sq Ft/Ft) 4.07 ft2/ft (1.24 m2 /m) Shelf Area
3
(Sq Ft/Ft) 11.32 ft2/ft (3.45 m2 /m)
1
AHRI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume/Unit of Length, ft3/ft [m3/m]
2
Computed using AHRI 1200 standard methodology: Total Display Area, ft2[m2]/Unit of Length, ft [m]
3
Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann Product Reference Guide. The standard shelf complement for this model is (4) rows of 22-inch shelves and (1) row of 18-inch shelves.
6 of 13 F6L Technical Data Sheet
U.S. & Canada 1-800-922-1919 • Mexico 1-800-522-1900
2
4 ft Wiring Diagram
Optional Stainless Steel Front Rail Heater, 67W
Reversing Non-Refrigerated Fan
Ambient Air Curtain - Muffin Fan
15W
12W
9W
Brown & Purple
Fans and
Anti-sweat Heaters
120V
Neutral
120V
Power
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
R = Red Y = Yellow G = Green BL = Blue BK = Black BR = Brown W = White
Main Evaporator Fans
Main Anti-Sweat Heater
(Honeycomb Divider)
Return Air Heater
100W - 1 pass Tubular Heater
90W 4-pass Foil Bond
11
1
3
6
12
10
BR
Relay
BK
R
Electric Defrost Fans & Anti-Sweat Heaters
7 of 13P/N 0518257_A
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
5
14
6
220V
Holding Coil
220V Power from Defrost Contactor
Reversing Relay
685W
U-Shaped Rod Mod. Defrost Heater
Refrigeration and Defrost Controls
Pink
L-2
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
R = Red Y = Yellow G = Green BL = Blue BK = Black W = White
7
Defrost (Rod) Heater 980W
1
1
2
2
Optional
Refrigeration
Thermostat
Dark
Blue
Defrost Terminator - 60
Defrost Circuit
Heater Limit Thermostat
8
9
Front Rail Light Switch 200W
Orange
120V
Neutral
120V
Power
T-8 ballast mounted in lower wireway
L-1
Red
T-8 Ballast
Ballast mounted next to muffin fans
left and center of canopy area
Lights
13
13
14
14
4 ft Wiring Diagram
Lighting Circuit
90 Open
on Rise
13
4
10A 10A
(Mounted above
left-hand rear coil)
Standard Electric
Light Circuit
Standard Electric
Defrost Circuit
8 of 13 F6L Technical Data Sheet
U.S. & Canada 1-800-922-1919 • Mexico 1-800-522-1900
Optional Stainless Steel
Front Rail Heater
200W - 12 ft, 133W - 8 ft, 94W - 6 ft
Brown & Purple
Fans and
Anti-sweat Heaters
120V
Neutral
120V
Power
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
Grayed components in 12 foot models only
R = Red Y = Yellow G = Green BL = Blue BK = Black BR = Brown W = White
Main Anti-Sweat Heater
(Honeycomb Divider)
Return Air Heater
1 pass Tubular Heater
300W - 12 ft, 200W - 8 ft, 150W - 6 ft
4-pass Foil Bond
270W 12 ft, 180W - 8 ft, 120W - 6 ft
11
6
12
10
BR
Relay
BK
R
1
3
6, 8, & 12 ft
Wiring Diagram
Reversing Non-Refrigerated Fans
Ambient Air Curtain - Muffin Fans
15W
12W
9W
Main Evaporator Fans
12 ft case shown in gray lines
12 ft case shown in gray lines
12 ft case shown in gray lines
2
Electric Defrost Fans & Anti-Sweat Heaters
9 of 13P/N 0518257_A
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
6
Reversing Relay
220V Holding Coil
220V Power from Defrost Contactor
685W ea 4 ft Tubular Heater 495W ea 3 ft Tubular Heater
U-Shaped Rod Modular Defrost Heaters
Refrigeration and Defrost Controls
Pink
L-2
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
Grayed components in 12 foot models only
R = Red Y = Yellow G = Green BL = Blue BK = Black W = White
2
1
1
1
1
2
2
2
Dark Blue
Defrost Circuit
Heater Limit Thermostat
(12 ft Case Only)
7
14
Lighting Circuit
Front Rail Light Switch
Orange
120V
Neutral
120V
Power
T-8 ballast mounted in lower wireway
12 ft case shown in gray lines
L-1
Red
T-8 Ballast
Ballast mounted next to muffin fans
left and center of canopy area
Lights
13
13
13
14
14
14
14
14
14
14
14
12 ft case shown in gray lines
9
8
6, 8, & 12 ft Wiring Diagram
Klixon mounted on right-hand plenum between fans
90
Open
on Rise
Defrost (Rod) Heater 2943W - 12 ft 1960W - 8 ft 1470W - 6 ft
10A 10A
5
Optional
Refrigeration
Thermostat
Defrost Terminator - 60
4
(
Mounted above
left-hand rear coil)
Standard Electric
Light Circuit
Standard Electric
Defrost Circuit
10 of 13 F6L Technical Data Sheet
U.S. & Canada 1-800-922-1919 • Mexico 1-800-522-1900
2
4 ft Wiring Diagram
Optional Stainless Steel
Front Rail Heater, 67W
Non-Refrigerated Fan
Ambient Air Curtain - Muffin Fan
15W
12W
7W
Brown & Purple
Fans and
Anti-sweat Heaters
120V
Neutral
120V
Power
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
R = Red Y = Yellow G = Green BL = Blue BK = Black W = White
Main Evaporator Fans
Main Anti-Sweat Heater
(Honeycomb Divider)
Return Air Heater
100W - 1 pass Tubular Heater
90W 4-pass Foil Bond
11
1
3
12
10
Gas Defrost Fans & Anti-Sweat Heaters
11 of 13P/N 0518257_A
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Pink
Optional
Refrigeration
Thermostat
5
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
R = Red Y = Yellow G = Green BL = Blue BK = Black W = White
4 ft Wiring Diagram
Lighting Circuit
Orange
120V
Neutral
120V
Power
T-8 ballast mounted in lower wireway
T-8 Ballast
Ballast mounted next to muffin fans
left and center of canopy area
Lights
13
13
14
14
Front Rail Light Switch
13
14
Gas Defrost
Light Circuit
& Thermostat
12 of 13 F6L Technical Data Sheet
U.S. & Canada 1-800-922-1919 • Mexico 1-800-522-1900
Optional Stainless Steel
Front Rail Heater
200W - 12 ft, 133W - 8 ft, 94W - 6 ft
Brown & Purple
Fans and
Anti-sweat Heaters
120V
Neutral
120V
Power
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
Grayed components in 12 foot models only
R = Red Y = Yellow G = Green BL = Blue BK = Black W = White
Main Anti-Sweat Heater
(Honeycomb Divider)
Return Air Heater
1 pass Tubular Heater
300W - 12 ft, 200W - 8 ft, 150W - 6 ft
4-pass Foil Bond
270W 12 ft, 180W - 8 ft, 120W - 6 ft
11
12
10
1
3
6, 8, & 12 ft
Wiring Diagram
Non-Refrigerated Fans
Ambient Air Curtain - Muffin Fans
15W
12W
7W
Main Evaporator Fans
12 ft case shown in gray lines
12 ft case shown in gray lines
12 ft case shown in gray lines
2
Gas Defrost Fans & Anti-Sweat Heaters
13 of 13P/N 0518257_A
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
13
14
14
14
13
14
14
14
14
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
Grayed components in 12 foot models only
R = Red Y = Yellow G = Green BL = Blue BK = Black W = White
Lighting Circuit
Orange
120V
Neutral
120V
Power
T-8 ballast mounted in lower wireway
12 ft case shown in gray lines
T-8 Ballast
Ballast mounted next to muffin fans
left and center of canopy area
Lights
13
12 ft case shown
in gray lines
14
6, 8, & 12 ft
Wiring Diagram
Front Rail Light Switch 200W
14
Pink
Optional
Refrigeration
Thermostat
5
Gas Defrost
Light Circuit
& Thermostat
Loading...