Hussmann F2XLG Technical Data Sheet

B
J
D
G
E
I
A
J
K
I
C
H
F
P/N 0424383_C
®
F2XLG
Technical Data Sheet
P/N 0424383_C
NSF
®
Certified
July 2007
©2007 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
Note: Changed items have been underlined.
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
Parts list on Page 2.
2 of 8 F2XLG Technical Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Item Part # Description Wiring Item #
F
AN ASSEMBLIES AND THERMOSTATS
A. 0382401 Fan Motor, Evaporator (ECM) (1)
12OV, 16W, CW (MO.4410113)
0315470 Fan Blade, Evaporator
embossing toward motor 8 in., 23°, CW (FB.0315470)
B. 0326081 Fan Motor -Muffin, Ambient (2)
12OV, 11W, 34 cfm, 3250 rpm (MO.4410571)
C. 0411744 Standard Non-adjustable (3)
Klixon Electric Defrost Thermostat (CT.0411744)
D. 0137880 Optional Adjustable (4)
Refrigeration Thermostat (CT.4481084)
L
AMPS AND BALLASTS
E. 0466234 Ballast 2 lamps (5)
(BA.4480823)
0376410 Ballast 3 lamps (BA.4480901)
F. Fluorescent Lamp (6)
Replace with like fixtures
Item Part # Description Wiring Item #
HEATERS
G. 0344662 Heater Limit Thermostat (7)
(CT.4440261)
H. 0495022
Defrost Heater, 208V, 685W (8) (HE.4850733)
0419217 Defrost Heater -6 ft (HE.4850568)
I. 0495025 Anti-Sweat Heater-4 ft (9)
(HE.4850734)
0496492
Anti-Sweat Heater-6 ft (HE.4850735)
0496493
Anti-Sweat Heater-8 ft (HE.4850736)
0496494
Anti-Sweat Heater-12 ft (HE.4850737)
J. 0495016
Reheat Heater -4, 8, & 12 ft (10) (HE.4850731)
0495021 Reheat Heater -6 ft (HE.4850732)
K. Multiglass-2 Pane,
(With Anti-Sweat Heater) (11)
0439925 4 foot case (GL.4966239) 0439926
6 foot case (GL.4962273)
0439927
8 and 12 foot case (GL.4985239)
Parts List
3 of 8P/N 0424383_C
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Engineering
Plan Views
Dimensions shown as inches and (mm).
F2XLG
4 ft 6 ft 8 ft 12 ft
General
(A) Case Length (without ends or partitions) 48 1/4 (1226) 72 1/4 (1835) 96 3/8 (2448) 144 1/2 (3670)
(Each end and insulated partition adds 1 1/2 in. (38 mm) to case line up.)
Maximum O/S dimension of case back to front
(includes bumper) 46
1
/2 (1181) 46 1/2 (1181) 46 1/2 (1181) 46 1/2 (1181) Back of case to front of splashguard 38 7/8 (987) 38 7/8 (987) 38 7/8 (987) 38 7/8 (987) Back of case to O/S edge of front skidrail 29 1/
4 (743) 29
1
/
4 (743) 29
1
/
4 (743) 29
1
/
4 (743)
Width of skidrail 2
1
/8 (54) 2 1/8 (54) 2 1/8 (54) 2 1/8 (54)
Stub-up area between front skidrail and splashguard 9 5/8 (245) 9 5/8 (245) 9 5/8 (245) 9 5/8 (245)
Electrical Service (Electrical Field Wiring connection point)
(B) RH End of case to center of farthest knockout 40 1/4 (1022) 64 1/4 (1632) 88 3/8 (2245) 138 7/8 (3527)
Back O/S of case to center of knockout 34 5/8 (880) 34 5/8 (880) 34 5/8 (880) 34 5/8 (880)
Waste Outlets (One each end)
(C) RH End of case to center of waste outlet 24 1/8 (613) 24 1/8 (613) 24 1/8 (613) 72 1/4 (1835)
LH End of case to center of waste outlet 24 1/8 (613) 48 1/8 (1222) 72 1/4 (1835) 72 1/4 (1835) Back O/S of case to center of waste outlets 27 1/2 (699) 27 1/2 (699) 27 1/2 (699) 27 1/2 (699) Edge of water seal to center of waste outlet 4 (102) 4 (102) 4 (102) 4 (102) O/S diameter of drip pipe lines 1 1/2 (38) 1 1/2 (38) 1 1/2 (38) 1 1/2 (38)
Note: Water seal outlet must clear front skid rail. F2 water seal rotation in forward direction only, due to low base.
Refrigeration Outlet
Back O/S of case to center of refrigeration outlet 30 5/8 (778) 30 5/8 (778) 30 5/8 (778) 30 5/8 (778) RH end of case to center of refrigeration outlet 9 (229) 9 (229) 9 (229) 9 (229)
A
B
72
1/4 (1835)
27
34
5/8
(880)
Elec.
9
5/8
Waste Outlet
(245)
Water Seal
(see note)
Front
1/2
(699)
C
29
1/4
30
(743)
9
(229)
4
(102)
Refrig.
5/8
38
(778)
7/8
(987)
46
1/2
(1181)
Loading...