Hussmann F Data Sheet

B
P/N0465894D
F
Technical Data Sheet
P/N 0465894_D
®
Certified
May 2010
Item Part # Description Wiring Item #
F
AN ASSEMBLIES, AND THERMOSTATS
A. 4W Standard Fan Assembly (1)
0392457 Fan Motor, Evaporator
(MO.4410101)
0464847 Fan Blade (FB.4780649) 4W Energy Efficient Fan Assembly (1) 0477653 Fan Motor, Evaporator
(MO.4410544)
0464847 Fan Blade (FB.4780649)
B. Optional Adjustable Refrigeration Thermostat (2)
C. 0398557 Defrost Termination Thermostat (3)
(Electric Defrost only) (CT.4440611)
D. 0481370 Heater Switch (4)
(Koolgas Defrost only) (CT.4440738)
Item Part # Description Wiring Item #
H
EATERS
E. 208V Evaporator Defrost Heaters (5)
0462159 8 ft case (HE.4850603) 0444058 12 ft case (HE.4850571)
F. 208V Drip Pan Defrost Heaters, Electric (6)
0462160 8 ft case (HE.4850636) 0444296 12 ft case (HE.4850572)
120V Drip Pan Defrost Heaters, Koolgas (7) 0465907 8 ft case (HE.4850622) 0465908 12 ft case (HE.4850623)
G. Nosing Anti-sweat Heaters (8)
0495007 8 ft case (HE.4850685) 0495008 12 ft case (HE.4850686)
Note: Revision D adds energy efficient fan Btu note and updates page 3. Changes are underlined, circled or marked with a vertical line in the margin.
©2010 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
F
G
C
A
E
D
2 of 7 F Technical Data Sheet
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
Engineering
Plan Views
Dimensions shown as inches and (mm).
10-2004
8 ft 12 ft
General
(A) Case Length (without ends or partitions) 96 3/
8 (2448) 144
1
/
2 (3670)
(Each end and insulated partition adds 2 in. (51 mm) to case line up.)
Maximum O/S dimension of case back to front (includes bumper) 42 (1065) 42 (1065) Back of case to front of splashguard 33 1/
2 (851) 33
1
/
2 (851)
Back of case to O/S edge of front leg 30
1
/4 (767) 30 1/4 (767) Distance between edges of external legs and center legs 41 1/2 (1054) 41 1/2 (1054) Distance between edges of center legs NA 43 7/8 (1114) Distance between front legs and splashguard 3 1/8 (82) 3 1/8 (82)
Electrical Service (Electrical Field Wiring connection point)
(B) RH End of case to center of stub up area 84 1/4 (2140) 132 3/8 (3363)
Back of case to center of stub up area 24 (612) 24 (612) Length of electrical wireway 26 1/2 (673) 26 1/2 (673)
(C) RH End of case to LH end of wireway 90 1/8 (2289) 138 1/4 (3511)
Waste Outlets (One each end)
(D) RH End of case to the center of LH waste outlet 84 1/4 (2141) 132 3/8 (3363)
RH End of case to the center of RH waste outlet 12 1/
8 (307) 12
1
/
8 (307)
Back O/S of case to center of waste outlets 31
5
/8 (804) 31 5/8 (804) Schedule 40 PVC drip pipe 1 1/
4 (32) 1
1
/
4 (32)
Refrigeration Outlet
Back of case to center of refrigeration outlet 26
1
/
4 (665) 26
1
/
4 (665)
RH end of case to center of refrigeration outlet 8 (203) 8 (203)
Low / Medium Temperature
Wireway
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/4 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
5
/8
F / FG
3 In.
(77 mm)
Required
Air Gap
24
(612)
Electrical Field Connection
41 1/2
(1054)
Electrical
Stub Up Area
6 x 6
(152 x 152)
Waste Outlet
Wireway
26 1/2 (673)
A
B
D
43 7/8
(1114)
4 1/4 (108)
4 3/4 (120)
Splashguard
41 1/2
(1054)
Refrigeration Outlet
Waste
Outlet
4 1/2 (115) 8 (203)
26 1/4
10 3/8
(263)
12 1/8 (307)
(665)
30 1/4
(767)
31 5/8
(804)
C
NOTE: Case-to-Case Electrical Connections are made IN FRONT OF SPLASHGUARD.
FRONT
33 1/2
(851)
42
(1065)
3 of 7P/N 0465894_D
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Case-to-Case Connection
FAN
COIL
Refrigeration Outlet
15 1/4 (388)
36 1/4 (921)
33 3/8 (848)
5
7
/8
(149)
3 1/2 (89)
26 3/4 (679)
26 1/4 (665)
19 7/8 (503)
F
31 5/8 (804)
33 1/2 (851)
42 (1065)
30 1/4 (767)
35 5/8
(905)
3 In.
(77 mm)
Required
Air Gap
Excel
F
Low / Medium Temperature
Single Level Wall Display with Solid Front
Dimensions shown as inches and (mm).
REFRIGERATION DATA
Note: This data is based on store temperature and
humidity that does not exceed 75°F and 55% R.H.
MED FF IC
Discharge Air (°F) +24 –12 –22
Evaporator(°F) +19 –20 –30
Unit Sizing (°F) +17 –23 –33
Btu/hr/ft
M
ED FF IC
Parallel 270
375 385
Conventional 280
390 400
Optional energy efficient motors reduce the refrigeration
load by 9 Btu/hr/ft.
DEFROST DATA
MED FF IC
Frequency (hr) 24 24 24
Defrost Water (lb/ft/day) 0.6 0.75 0.8
(± 15% based on case configuration and product
loading).
ELECTRIC MED FF IC
Temp Term (°F) 48 48 48
Failsafe (minutes) 60 60 60
G
AS
Duration (minutes) NA 15 18
O
FFTIME
Not Recommended
Standard Defrost Thermostat
Close on rise: close 48°F — open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control — CI/CO *
M
ED +12°F / +2°F
FF –17°F / –29°F
IC –27°F / –39°F
Indoor Unit Only, Pressure Defrost Termination*
Not Recommended
*Use a Temperature Pressure Chart to determine PSIG
conversions.
Estimated Charge **
8 ft 2.0 lb 32 oz 0.9 kg
12 ft 3.0 lb 48 oz 1.4 kg
**This is an average for all refrigerant types. Actual
refrigerant charge may vary by approximately 0.5 lb
(8 oz / 0.2 kg)
.
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.