Hussmann F Data Sheet

Page 1
B
P/N0465894D
F
Technical Data Sheet
P/N 0465894_D
®
Certified
May 2010
Item Part # Description Wiring Item #
F
AN ASSEMBLIES, AND THERMOSTATS
A. 4W Standard Fan Assembly (1)
0392457 Fan Motor, Evaporator
(MO.4410101)
0464847 Fan Blade (FB.4780649) 4W Energy Efficient Fan Assembly (1) 0477653 Fan Motor, Evaporator
(MO.4410544)
0464847 Fan Blade (FB.4780649)
B. Optional Adjustable Refrigeration Thermostat (2)
C. 0398557 Defrost Termination Thermostat (3)
(Electric Defrost only) (CT.4440611)
D. 0481370 Heater Switch (4)
(Koolgas Defrost only) (CT.4440738)
Item Part # Description Wiring Item #
H
EATERS
E. 208V Evaporator Defrost Heaters (5)
0462159 8 ft case (HE.4850603) 0444058 12 ft case (HE.4850571)
F. 208V Drip Pan Defrost Heaters, Electric (6)
0462160 8 ft case (HE.4850636) 0444296 12 ft case (HE.4850572)
120V Drip Pan Defrost Heaters, Koolgas (7) 0465907 8 ft case (HE.4850622) 0465908 12 ft case (HE.4850623)
G. Nosing Anti-sweat Heaters (8)
0495007 8 ft case (HE.4850685) 0495008 12 ft case (HE.4850686)
Note: Revision D adds energy efficient fan Btu note and updates page 3. Changes are underlined, circled or marked with a vertical line in the margin.
©2010 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
F
G
C
A
E
D
Page 2
2 of 7 F Technical Data Sheet
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
Engineering
Plan Views
Dimensions shown as inches and (mm).
10-2004
8 ft 12 ft
General
(A) Case Length (without ends or partitions) 96 3/
8 (2448) 144
1
/
2 (3670)
(Each end and insulated partition adds 2 in. (51 mm) to case line up.)
Maximum O/S dimension of case back to front (includes bumper) 42 (1065) 42 (1065) Back of case to front of splashguard 33 1/
2 (851) 33
1
/
2 (851)
Back of case to O/S edge of front leg 30
1
/4 (767) 30 1/4 (767) Distance between edges of external legs and center legs 41 1/2 (1054) 41 1/2 (1054) Distance between edges of center legs NA 43 7/8 (1114) Distance between front legs and splashguard 3 1/8 (82) 3 1/8 (82)
Electrical Service (Electrical Field Wiring connection point)
(B) RH End of case to center of stub up area 84 1/4 (2140) 132 3/8 (3363)
Back of case to center of stub up area 24 (612) 24 (612) Length of electrical wireway 26 1/2 (673) 26 1/2 (673)
(C) RH End of case to LH end of wireway 90 1/8 (2289) 138 1/4 (3511)
Waste Outlets (One each end)
(D) RH End of case to the center of LH waste outlet 84 1/4 (2141) 132 3/8 (3363)
RH End of case to the center of RH waste outlet 12 1/
8 (307) 12
1
/
8 (307)
Back O/S of case to center of waste outlets 31
5
/8 (804) 31 5/8 (804) Schedule 40 PVC drip pipe 1 1/
4 (32) 1
1
/
4 (32)
Refrigeration Outlet
Back of case to center of refrigeration outlet 26
1
/
4 (665) 26
1
/
4 (665)
RH end of case to center of refrigeration outlet 8 (203) 8 (203)
Low / Medium Temperature
Wireway
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/4 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
5
/8
F / FG
3 In.
(77 mm)
Required
Air Gap
24
(612)
Electrical Field Connection
41 1/2
(1054)
Electrical
Stub Up Area
6 x 6
(152 x 152)
Waste Outlet
Wireway
26 1/2 (673)
A
B
D
43 7/8
(1114)
4 1/4 (108)
4 3/4 (120)
Splashguard
41 1/2
(1054)
Refrigeration Outlet
Waste
Outlet
4 1/2 (115) 8 (203)
26 1/4
10 3/8
(263)
12 1/8 (307)
(665)
30 1/4
(767)
31 5/8
(804)
C
NOTE: Case-to-Case Electrical Connections are made IN FRONT OF SPLASHGUARD.
FRONT
33 1/2
(851)
42
(1065)
Page 3
3 of 7P/N 0465894_D
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Case-to-Case Connection
FAN
COIL
Refrigeration Outlet
15 1/4 (388)
36 1/4 (921)
33 3/8 (848)
5
7
/8
(149)
3 1/2 (89)
26 3/4 (679)
26 1/4 (665)
19 7/8 (503)
F
31 5/8 (804)
33 1/2 (851)
42 (1065)
30 1/4 (767)
35 5/8
(905)
3 In.
(77 mm)
Required
Air Gap
Excel
F
Low / Medium Temperature
Single Level Wall Display with Solid Front
Dimensions shown as inches and (mm).
REFRIGERATION DATA
Note: This data is based on store temperature and
humidity that does not exceed 75°F and 55% R.H.
MED FF IC
Discharge Air (°F) +24 –12 –22
Evaporator(°F) +19 –20 –30
Unit Sizing (°F) +17 –23 –33
Btu/hr/ft
M
ED FF IC
Parallel 270
375 385
Conventional 280
390 400
Optional energy efficient motors reduce the refrigeration
load by 9 Btu/hr/ft.
DEFROST DATA
MED FF IC
Frequency (hr) 24 24 24
Defrost Water (lb/ft/day) 0.6 0.75 0.8
(± 15% based on case configuration and product
loading).
ELECTRIC MED FF IC
Temp Term (°F) 48 48 48
Failsafe (minutes) 60 60 60
G
AS
Duration (minutes) NA 15 18
O
FFTIME
Not Recommended
Standard Defrost Thermostat
Close on rise: close 48°F — open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control — CI/CO *
M
ED +12°F / +2°F
FF –17°F / –29°F
IC –27°F / –39°F
Indoor Unit Only, Pressure Defrost Termination*
Not Recommended
*Use a Temperature Pressure Chart to determine PSIG
conversions.
Estimated Charge **
8 ft 2.0 lb 32 oz 0.9 kg
12 ft 3.0 lb 48 oz 1.4 kg
**This is an average for all refrigerant types. Actual
refrigerant charge may vary by approximately 0.5 lb
(8 oz / 0.2 kg)
.
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.
Page 4
F Technical Data Sheet
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
4 of 7
Excel
F
Low / Medium Temperature
Electrical Data
8 ft 12 ft
Number of Fans – 4W Evaporator 2 2
Amperes Watts
8 ft 12 ft 8 ft 12 ft
Evaporator Fans
120V 60Hz Standard 0.62 0.62 48 48
120V 50Hz Standard 0.76 0.76 54 54
230V 60Hz Export 0.30 0.30 48 48
230V 50Hz Export 0.36 0.36 54 54
120V 60Hz Energy Efficient 0.24 0.24 16 16
230V 60Hz Energy Efficient 0.12 0.12 16 16
Anti-sweat Heaters (on fan circuit)
120V 50/60Hz Standard 0.67 1.00 80 120
230V 50/60Hz Export 0.35 0.52 80 120
Minimum Circuit Ampacity
120V 60Hz Standard 1.49 1.82
120V 50Hz Standard 1.63 1.96
230V 60Hz Export 0.85 1.02
230V 50Hz Export 0.91 1.08
120V 60Hz Energy Efficient 1.11 1.44
230V 60Hz Energy Efficient 0.67 0.84
Maximum Over Current Protection 120V 20 20
Maximum Over Current Protection 230V 15 15
208V Electric Defrost 7.69 11.54 1600 2400
230V Export Electric Defrost 6.96 10.43 1600 2400
120V Koolgas Defrost 1.67 3.33 200 400
Standard Lighting
None
Page 5
5 of 7P/N 0465894_D
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
ESTIMATED SHIPPING WEIGHT
4
Case Solid End
4 ft 6 ft 8 ft 12 ft (each)
lb (kg) NA (NA) NA (NA) 1000 (454) 1200 (544) 50 (23)
4
Actual weights will vary according to optional kits included.
Excel
F
Low / Medium Temperature
Product Data
Recommended Usable Cube 1(Cu Ft/Ft) 3.55 ft3 /ft (0.33 m3 /m) AHRI Total Display Area 2(Sq Ft/Ft) 2.78 ft2/ft (0.85 m2 /m) Shelf Area 3(Sq Ft/Ft) 2.79 ft2/ft (0.85 m2 /m)
1
AHRI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume/Unit of Length, ft3/ft [m3/m]
2
Computed using AHRI 1200 standard methodology: Total Display Area, ft2[m2]/Unit of Length, ft [m]
3
Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann Product Reference Guide. The standard shelf complement for this model is NONE.
Page 6
6 of 7
Red
208 V Power From Defrost Contactors
L1
L2
Electric Defrost Heaters
Drip Pan Heater
6
Red
5
Defrost Termination Thermostat
Dark Blue
To Condensing Unit
}
3
Light Blue
2
To Condensing Unit
}
Refrigeration Thermostat (Optional)
1
BROWN BAND
Fans
BROWN BAND
Nosing
Anti-sweat
Heater
120V POWER
120V NEUTRAL
8
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
Circled Numbers = Parts List Item Numbers.
Electric Defrost – Standard
F Technical Data Sheet
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
Page 7
7 of 7P/N 0465894_D
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Gas Defrost – Optional
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
Circled Numbers = Parts List Item Numbers.
7
4
120V Drip Pan Heater — Koolgas Only
Yellow
Heater Switch
Yellow
120V POWER
120V NEUTRAL
Dark Blue
Dark Blue
Loading...