Hussmann ESGMVS Specifications

Page 1
D
P/N 0474008_B
ESGMVS
Technical Data Sheet
NSF
®
Certified
December 2006
Item Part # Description Wiring Item #
FAN ASSEMBLIES AND THERMOSTATS
A. 0404551 Fan Motor, Ambient (120V) (1)
(MO.0404551)
0404552 Fan Motor, Ambient (230V)
(MO.4410590)
B. 0353949 Optional Adjustable (2)
Refrigeration Thermostat
(CT.4481087)
Item Part # Description Wiring Item #
LAMPS AND BALLASTS
C. 0355716 Ballast, Electronic, 2 lamps
(120V) (BA.0355716) (3)
C. 0355398 Ballast, Electronic, 3 lamps
(120V) (BA.4480118) (4)
C. 0440215 Ballast, Electronic, 2 lamps
(230V 50-60 Hz) (BA.4481267) (3)
C. 0428652 Ballast, Electronic, 3 lamps
(230V 50-60 Hz) (BA.4480897) (4)
0385104 Ballast Transformer
(230V 50-60 Hz, per ballast) (TR.4481191)
D. Fluorescent Lamp (5)
Replace with like fixtures
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
©2006 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
Note: Revision B added the After Market numbers and changed the interior height of the case on Page 3.
Thermostat Bulb
Location
B
(Optional
Lights)
A
C
Page 2
4 ft 6 ft 8 ft 12 ft
General
(A) Case Length (without ends or partitions) 48 1/
4 (1226) 72
3
/
8 (1838) 96
3
/
8 (2448) 144
1
/
2 (3670)
(Each end and insulated partition adds 1 in. (26 mm) to case line up.)
Maximum O/S dimension back to front (with bumper) 46 (1168) 46 (1168) 46 (1168) 46 (1168) Back of case to front of front panel 33 1/
4 (845) 33
1
/
4 (845) 33
1
/
4 (845) 33
1
/
4 (845)
RH end of case to outside edge of external support 1
5
/8 (41) 1 5/8 (41) 1 5/8 (41) 1 5/8 (41)
Distance between edges of
external support and center support NA 28 1/
2 (724) 40
5
/
8 (1032) 40
5
/
8 (1032)
Distance between edges of center supports NA NA NA 44 (1118) Distance between edges of external supports 37 (940) NA NA NA
Electrical Service (Electrical Field Wiring connection point)
(C) Length of electrical raceway 38
3
/4 (984) 29 5/8 (752) 41 3/4 (1060) 41 3/4 (1060) RH End of case to center of farthest knockout 10 3/8 (264) 10 (254) 10 3/8 (264) 10 1/4 (260) Back of case to center of end knockout 3 5/8 (92) 3 5/8 (92) 3 5/8 (92) 3 5/8 (92)
(B) RH End of case to RH end of raceway 5 (127) 5 (127) 5 (127) 5 (127)
Waste Outlet
(D) RH End of case to the center of waste outlet 24 (610) 24 1/8 (613) 24 1/8 (613) 72 1/4 (1835)
LH End of case to the center of waste outlet 24 1/4 (616) 48 1/4 (1226) 72 1/4 (1835) 72 1/4 (1835) Back O/S of case to center of waste outlet 26 1/4 (667) 26 1/4 (667) 26 1/4 (667) 26 1/4 (667)
Water Seal
Edge of water seal to center of waste outlet 4 (102) 4 (102) 4 (102) 4 (102) Outside diameter of the drip pipe 1 1/2 (38) 1 1/2 (38) 1 1/2 (38) 1 1/2 (38)
(Field installed water seal outlets, tees, and connectors
are shipped with the merchandiser.)
Refrigeration Outlet
Back of case to center of refrigeration outlet 29 3/8 (746) 29 3/8 (746) 29 3/8 (746) 29 3/8 (746)
(E) RH end of case to center of refrigeration outlet 8 1/4 (210) 8 1/4 (210) 8 1/4 (210) 8 1/4 (210)
ESGMVS Technical Data Sheet 2 of 6
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Engineering
Plan Views
Dimensions shown as in. and (mm).
Elite Vertical Hinged Glass
Meat & Delicatessen
A
D
C
Legs
Waste Outlet
C
L
Front
Water Seal
3 5/8 (92)
Electrical
Refrigeration Outlet
E
B
26 1/4
(667)
29 3/8
(746)
33 1/4
(845)
46
(1168)
Page 3
REFRIGERATION DATA
Note: This data is based on store temperature
and humidity that does not exceed 75°F and 55% R.H. Schedule defrost at night while lights are off.
ESGMVS
Discharge Air (°F) 27
Evaporator (°F) 22
Unit Sizing (°F) 20
Btu/hr/ft
ESGMVS
Parallel
320
Conventional
350
DEFROST DATA
ESGMVS
Frequency (hr) 24
Defrost Water (lb/ft/day) 0.65
(± 15% based on case configuration and
product loading).
ESGMVS
O
FFTIME
(minutes) 75
Failsafe (minutes) 90
E
LECTRIC OR GAS Not Recommended
CONVENTIONAL CONTROLS
Low Pressure Backup Control
ESGMVS
CI/CO (Temp °F)* 15 / 5
Indoor Unit Only, Pressure Defrost
Termination(Temp °F)*
Not Recommended
*Use a Temperature Pressure Chart to determine PSIG conversions.
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1
1
/2
Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
5
/8
Estimated Charge (lb)**
4 ft 0.8
6 ft 1.2
8 ft 1.5
12 ft 2.0
**This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound.
3 of 6P/N 0474008_B
Dimensions shown as inches and (mm).
Impact
Elite
ESGMVS
Meat / Delicatessen
Elite Vertical Hinged Glass, Gravity Coil and Serpentine Coil, Single Display Level
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
NSF Certification
These merchandisers are manufactured to meet ANSI /National Sanitation Foundation (NSF
®
) Standard #7 requirements.
ESGMVS
19 3/4
(502)
COIL
27 1/4
17
(432)
32 1/2
(826)
(692)
52 7/8
(1343)
18
(457)
Refrigeration
Outlet
F A N
20
(508)
Electrical
13 1/4
(337)
25 1/2
(648)
17 3/8
(441)
4 (102)
26 1/4
29 3/8
(667)
(746)
12 3/4
(324)
33 1/4
(845)
46
(1168)
Page 4
ESGMVS Technical Data Sheet 4 of 6
Impact Elite ESGMVS
Meat / Delicatessen
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Electrical Data
Number of Fans 4 ft 6 ft 8 ft 12 ft
Refrigeration N/A
Ambient Air Wipe – 15W 2 4 4 6
Export Refrigeration N/A
Export Ambient Air Wipe – 15W 2 4 4 6
Amperes Watts
Merchandiser 4 ft 6 ft 8 ft 12 ft 4 ft 6 ft 8 ft 12 ft
Refrigeration Fans N/A
Ambient Air Wipe Fans
Standard (120V 60hz) 0.52 1.04 1.04 1.56 45 90 90 136
Energy Efficient(120V 60hz) N/A
Export: 230V 50 hz 0.30 0.60 0.60 0.90 50 100 100 150
Constant On Anti-sweat Heaters N/A
Cycling Anti-sweat Heaters N/A
Minimum Circuit Ampacity
With Standard Fans (120V 60hz) 0.72 1.24 1.24 1.76
With Energy Efficient Fans (120V 60hz) N/A
With Export Fans (230V 50 hz ) 0.50 0.80 0.80 1.10
Maximum Over Circuit Protection 120V 20
Maximum Over Circuit Protection 230V 15
Standard Lighting* (120V 60hz) 4 ft 6 ft 8 ft 12 ft 4 ft 6 ft 8 ft 12 ft
2 Row Canopy 0.49 0.98 0.98 1.42 59 118 118 171
Optional Lighting
1 Row Ledge 0.49 0.49 0.49 0.71 59 59 59 86
1 Row Rail 0.49 0.49 0.49 0.71 59 59 59 86
*230V lighting values are under review.
Page 5
P/N 0474008_B 5 of 6
Fans
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
4 ft case has 2 Fan 6 ft case has 4 Fans 8 ft case has 4 Fans 12 ft case has 6 Fans
120V POWER
BROWN BAND
Fans
Ambient Fan Wiring
Glass Air Wipe
Offtime Defrost
120V NEUTRAL
BROWN BAND
1
Refrigeration
Thermostat
2
(Field Installed)
Light Blue
Light Blue
To Condensing Unit
}
Electric Service Receptacle
Receptacles
120V NEUTRAL
120V POWER
N.E.C.
TAGS
MAROON
BAND
All components must have mechanical ground, and the merchandiser must be grounded.
R = Red G = Green BL = Blue LB = Light Blue DB = Dark Blue B = Black W = White
= 120V P
MAROON
BAND
W
G
B
WARNING
Circled Numbers = Parts List Item Numbers
Grayed components in 12 foot models only.
OWER = 120V NEUTRAL = Field GROUND
= Case GROUND
Page 6
ESGMVS Technical Data Sheet 6 of 6
Light Circuits
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Standard Lighting — 2 Row Canopy
120V NEUTRAL
ORANGE OR TAN BAND
120V POWER
ORANGE OR TAN BAND
Light
Switch
B
W
3
G
W
B
GG
BL
BL
R
BL
55
R
5
G
R
Optional Ledge Light Circuit
or
Optional Rail Light Circuit
BG
W
3
BL
BL
R
BL
G
BL
G
R
5
G
BL
R
55
3
BL
R
BL
G
BL
G
R
5
G
R
55
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
Circled Numbers = Parts List Item Numbers
Grayed components in 12 foot models only.
R = Red G = Green BL = Blue B = Black W = White
= 120V POWER = 120V NEUTRAL = Field GROUND
= Case GROUND
Loading...