Hussmann ESBDVS Specifications

Thermostat Bulb
Location
(Optional
Lights)
G
C
F
B
G
A
D
P/N 0506799_A
Item Part # Description Wiring Item #
F
AN ASSEMBLIES AND
THERMOSTATS
A. 0392457 Fan Motor, Evaporator (120V) (1)
(MO.4410101)
0409511 Fan Blade (120V) (FB.0409511)
embossing toward motor
0436517 Fan Motor, Evaporator (230V)
(MO.4410105)
0409512 Fan Blade (230V) (FB.0409512)
embossing toward motor
B. 0404551 Fan Motor, Ambient (120V) (2)
(MO.0404551)
0404552 Fan Motor, Ambient (230V)
(MO.4410590)
C. 0382028 Standard Non-adjustable (3)
Defrost Thermostat
(CT.0382028)
D. Optional Adjustable Refrigeration Thermostat(4)
0353949 (CT.4481087)
Item Part # Description Wiring Item #
HEATERS
E. 0460453 Heater, Ambient (120V) (5)
(HE.4850579)
E. 0461866 Heater, Ambient (230V) (6)
(HE.4850646)
L
AMPS AND BALLASTS
Ballast, Electronic
F. 0355716 2 lamps (120V) (BA.0355716) (7) F. 0355398 3 lamps (120V) (BA.4480118) (8) F. 0440215 2 lamps (230V 50-60 Hz)
(BA.4481267) (7)
F. 0428652 3 lamps(230V 50-60 Hz)
(BA.4480897) (8)
0385104 Ballast Transformer
(230V 50-60 Hz, per ballast) (TR.4481191)
G. Fluorescent Lamp (9)
Replace with like fixtures
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
©2008 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
ESBDVS
Technical Data Sheet
P/N 0506799_A
NSF
®
Certified
September 2008
Supersedes
P/N 0474007_B
Note: P/N 0506799 supersedes P/N 0474007_B; removes EEF; adds Product Data, page 5.
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
ESBDVS Technical Data Sheet 2 of 6
26 1/4
(667)
A
D
C
46
(1168)
29 3/8
(746)
3 5/8 (92)
E
33 1/4
(845)
Legs
Water Seal
C
L
Front
Refrigeration Outlet
Electrical
B
Waste Outlet
Elite Meat & Delicatessen
Straight Hinged Glass Models
Engineering
Plan Views
4 ft 6 ft 8 ft 12 ft
General
(A) Case Length (without ends or partitions) 48 1/
4 (1226) 72
3
/
8 (1838) 96
3
/
8 (2448) 144
1
/
2 (3670)
(Each end and insulated partition adds 1 in. (25 mm) to case line up.)
Maximum O/S dimension back to front (with bumper) 46 (1168) 46 (1168) 46 (1168) 46 (1168) Back of case to front of front panel 33 1/4 (845) 33 1/4 (845) 33 1/4 (845) 33 1/4 (845) RH end of case to outside edge of external support 1 5/
8 (41) 1
5
/
8 (41) 1
5
/
8 (41) 1
5
/
8 (41)
Distance between edges of
external support and center support NA 28
1
/2 (724) 40 5/8 (1032) 40 5/8 (1032) Distance between edges of center supports NA NA NA 44 (1118) Distance between edges of external supports 37 (940) NA NA NA
Electrical Service (Electrical Field Wiring connection point)
(C) Length of electrical raceway 38 3/4 (984) 29 5/8 (752) 41 3/4 (1060) 41 3/4 (1060)
RH End of case to center of farthest knockout 10 3/8 (264) 10 (254) 10 1/4 (260) 10 1/4 (260) Back of case to center of end knockout 3 5/8 (92) 3 5/8 (92) 3 5/8 (92) 3 5/8 (92)
(B) RH End of case to RH end of raceway 5 (127) 5 (127) 5 (127) 5 (127)
Waste Outlet
(D) RH End of case to the center of waste outlet 24 (610) 24 1/8 (613) 24 1/8 (613) 72 1/4 (1835)
LH End of case to the center of waste outlet 24 1/4 (616) 48 1/4 (1226) 72 1/4 (1835) 72 1/4 (1835) Back O/S of case to center of waste outlet 26 1/4 (667) 26 1/4 (667) 26 1/4 (667) 26 1/4 (667)
Water Seal
Edge of water seal to center of waste outlet 4 (102) 4 (102) 4 (102) 4 (102) Outside diameter of the drip pipe 1 1/2 (38) 1 1/2 (38) 1 1/2 (38) 1 1/2 (38)
(Field installed water seal outlets, tees, and connectors
are shipped with the merchandiser.)
Refrigeration Outlet
Back of case to center of refrigeration outlet 29 3/8 (746) 29 3/8 (746) 29 3/8 (746) 29 3/8 (746)
(E) RH end of case to center of refrigeration outlet 8 1/4 (210) 8 1/4 (210) 8 1/4 (210) 8 1/4 (210)
Dimensions shown as in. and (mm).
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/2 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
7
/8
12 ft plan view is shown.
REFRIGERATION DATA
Note: This data is based on store temperature and
humidity that does not exceed 75°F and 55% R.H.
ESBDVS
Discharge Air (°F) 25
Evaporator (°F) 20
Unit Sizing (°F) 18
Btu/hr/ft — Unlit Shelves ESBDVS
‡‡
Parallel
315
Conventional
380
‡‡
Add 10 Btu/hr/ft per shelf row for LED fixtures.
‡‡
Add 20 Btu/hr/ft per shelf row for fluorescent lamps.
DEFROST DATA
ESBDVS
Frequency (hr) 12 Defrost Water (lb/ft/day) 0.5
(± 15% based on case configuration and product
loading).
O
FFTIME
ESBDVS Temp Term (°F) 43 Failsafe (minutes) 90
E
LECTRIC OR GAS
Not Recommended
Standard Defrost Thermostat
Close on rise: close 43°F — open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control
ESBDVS CI/CO (Temp °F)* 13 Indoor Unit Only, Pressure Defrost Termination (Temp °F)*
Not Recommended
*Use a Temperature Pressure Chart to determine PSIG conversions.
Estimated Charge (lb)**
4 ft 0.8 6 ft 1.2 8 ft 1.5
12 ft 2.0
**This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound.
3 of 6P/N 0506799_A
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
18
(457)
52 7/8
(1343)
46
(1168)
25 1/2
(648)
17 3/8
(441)
4 (102)
27 1/4
(692)
33 1/4
(845)
26 1/4
(667)
29 3/8
(746)
13 1/4
(337)
20
(508)
23
(584)
30 7/8
(784)
19 3/4
(502)
12 3/4
(324)
ESBDVS
Refrigeration
Outlet
Electrical
COIL
FA N
F A N
Shown with Optional Shelves
Dimensions shown as in. and (mm).
Impact Elite ESBDVS
Meat & Delicatessen
Elite Straight Hinged Glass, Blower, 1 Display Level
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.