Hussmann ES1S Specifications

Page 1
P/N 0506801_A
G
C
(Optional
Lights)
B
A
F
E
D
Location
Item Part # Description Wiring Item #
FAN ASSEMBLIES AND THERMOSTATS
A. 4W Standard Fan Assembly (1)
0392457 Fan Motor, Evaporator
(MO.4410101)
0409513 Fan Blade, (FB.0409513)
embossing toward motor
B. 0404551 Fan Motor, Ambient (2)
(MO.0404551)
C. 0411744 Standard Non-adjustable (3)
Defrost Thermostat (CT.0411744)
Item Part # Description Wiring Item #
D. 0137880 Optional Adjustable (4)
Refrigeration Thermostat (CT.4481084)
HEATERS
E. 0496496 Heater, Anti-Sweat (5)
(HE.4850738)
LAMPS AND BALLASTS
F. 0355716 Ballast, Electronic
2 lamps (BA.0355716) (6)
0355398 Ballast, Electronic
3 lamps (BA.4480118)
G. Fluorescent Lamp (7)
Replace with like fixtures
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
©2008 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
ES1S
Technical Data Sheet
P/N 0506801_A
NSF
®
Certified
September 2008
Supersedes
P/N 0453557_B
Note: P/N 0506801 supersedes P/N 0453557_B; removes EEF; adds Product Data, page 5.
Page 2
2 of 7 ES1S Technical Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Engineering
Plan Views
Dimensions shown as inches and (mm).
10-2005
27 1/8
(689)
A
D
C
46 1/8
(1172)
30 1/4
(768)
5 1/4 (133)
E
34 1/8
(867)
Legs
Water Seal
C
L
Front
Refrigeration Outlet
Electrical
B
Waste Outlet
ES1S
Delicatessen
Precut & Packaged
Produce
4 ft 6 ft 8 ft 12 ft
General
(A) Case Length (without ends or partitions) 48 1/
4 (1226) 72
3
/
8 (1838) 96
3
/
8 (2448) 144
1
/
2 (3670)
(Each end and insulated partition adds 1 in. (25 mm) to case line up.)
Maximum O/S dimension back to front (with bumper) 46 1/
8 (1172) 46
1
/
8 (1172) 46
1
/
8 (1172) 46
1
/
8 (1172)
Back of case to front of front panel 34
1
/
8 (867) 34
1
/
8 (867) 34
1
/
8 (867) 34
1
/
8 (867)
RH end of case to outside edge of external support 1
3
/8 (35) 1 3/8 (35) 1 3/8 (35) 1 3/8 (35)
Distance between edges of
external support and center support NA 28 1/
2 (724) 40
1
/
2 (1029) 40
1
/
2 (1029)
Distance between edges of center supports NA NA NA 43
7
/8 (1114)
Distance between edges of external supports 37 (940) NA NA NA
Electrical Service (Electrical Field Wiring connection point)
(C) Length of electrical raceway 34 1/2 (876) 26 (660) 38 (965) 38 (965)
RH End of case to center of farthest knockout 12 1/4 (311) 12 1/4 (311) 12 1/4 (311) 12 1/4 (311) Back of case to center of end knockout 5 1/4 (133) 5 1/4 (133) 5 1/4 (133) 5 1/4 (133)
(B) RH End of case to RH end of raceway 6 7/8 (175) 6 7/8 (175) 6 7/8 (175) 6 7/8 (175)
Waste Outlet
(D) RH End of case to the center of waste outlet 24 1/8 (613) 24 1/8 (613) 24 1/8 (613) 72 1/4 (1835)
LH End of case to the center of waste outlet 24 1/8 (613) 48 1/4 (1226) 72 1/4 (1835) 72 1/4 (1835) Back O/S of case to center of waste outlet 27 1/8 (689) 27 1/8 (689) 27 1/8 (689) 27 1/8 (689)
Water Seal
Edge of water seal to center of waste outlet 4 (102) 4 (102) 4 (102) 4 (102) Outside diameter of the drip pipe 1 1/2 (38) 1 1/2 (38) 1 1/2 (38) 1 1/2 (38)
(Field installed water seal outlets, tees, and connectors
are shipped with the merchandiser.)
Refrigeration Outlet
Back of case to center of refrigeration outlet 30 1/4 (768) 30 1/4 (768) 30 1/4 (768) 30 1/4 (768)
(E) RH end of case to center of refrigeration outlet 8 3/8 (213) 8 3/8 (213) 8 3/8 (213) 8 3/8 (213)
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/2 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
7
/8
12 ft plan view is shown.
Page 3
REFRIGERATION DATA
Note: This data is based on store temperature and
humidity that does not exceed 75 (°F) and 55% R.H.
ES1
Discharge Air (°F) 28
Evaporator (°F) 20
Unit Sizing (°F) 18
Btu/hr/ft ES1
‡‡
Parallel 250
Conventional 270
DEFROST DATA
ES1
Frequency (hr) 12
Defrost Water 0.8 lb/ft/day
(± 15% based on case configuration and product
loading).
OFFTIME ES1
Temp Term (°F) 43
Failsafe (minutes) 90
ELECTRIC OR GAS Not Recommended
Standard Defrost Thermostat
Close on rise: close 48°F – open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control
CI/CO
* ES1
Temp 13°F / 3°F
Indoor Unit Only, Pressure Defrost
Termination (Temp °F)
*
43°F
*Use a Temperature Pressure Chart to determine
PSIG conversions.
Estimated Charge (lb)** ES1
4 ft 0.8
6 ft 1.2
8 ft 1.5
12 ft 2.0
**This is an average for all refrigerant types actual
refrigerant charge may vary by approximately half a
pound.
FAN
COIL
ES1S
34 1/8
(867)
37
(940)
8 1/4
(210)
52 1/8
(1324)
22
(559)
21 3/4
(552)
33 1/8
(841)
7 (178)
14 5/8
(371)
46 1/8
(1172)
4 3/4
(121)
12
(305)
27 1/8
(689)
30 1/4
(768)
Refrigeration Outlet
3 of 7
P/N 0506801_A
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Impact
Elite
ES1S
Delicatessen
Precut & Packaged Produce
Elite specialty service merchandiser, straight front glass, 1 display level
Dimensions shown as in. & (mm).
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.
Page 4
4 of 7 ES1S Technical Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Impact
Elite
ES1S
Delicatessen Precut & Packaged Produce
Electrical Data
4 ft 6 ft 8 ft 12 ft
Number of Fans — 4W 1223
Number of Fans — 4W (Export) 1223
(Export: 230V 50 hz shown)
Ambient Air Wipe — 15W 2446
Amperes Watts
Merchandiser 4 ft 6 ft 8 ft 12 ft 4 ft 6 ft 8 ft 12 ft
Fans
120V 60Hz Standard 0.31 0.62 0.62 0.93 24 48 48 72
230V 50Hz Export 0.18 0.36 0.36 0.54 27 54 54 81
Fans (Ambient Air Wipe)
120V 60Hz Two-pole Muffin Fan 0.52 1.04 1.04 1.56 0.30 60 60 90
230V 50Hz Export 0.3 0.6 0.6 0.9
Constant On Anti-sweat Heaters 0.13 0.26 0.26 0.39 16 32 32 48
Minimum Circuit Ampacity
120V 60Hz Standard Fans 1.16 2.12 2.12 3.08
230V 50Hz Export Fans 0.68 1.16 1.16 1.64
Maximum Over Current Protection 20 20 20 20
230V 50Hz Export 15 15 15 15
Standard Lighting
2 Rows Canopy 0.49 0.98 0.98 1.42 59 118 118 171
Optional Lighting (T-8 fluorescent)
1 Row of Rail Lights 0.49 0.49 0.49 0.71 59 59 59 86
1 Row of Ledge Lights 0.49 0.49 0.49 0.71 59 59 59 86
Optional Always*Bright LED Lighting
2 Row of Shelves 0.26 0.34 0.47 0.67 31 41 56 80
115V Lighting Circuit Total = Standard Lighting + Total Optional Lighting
230V Lighting Circuit Total = Multiply 115V Lighting Circuit Total by 0.52do
Page 5
5 of 7
P/N 0506801_A
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Impact
Elite
ES1S
Delicatessen
Precut & Packaged Produce
Product Data
ARI Refrigerated Volume 1 (Cu Ft/Ft) 3.89 ft3/ft (0.36 m3/m) Recommended Usable Cube
2
(Cu Ft/Ft) 1.61 ft3 /ft (0.15 m3 /m)
ARI Total Display Area
3
(Sq Ft/Ft) 3.55 ft2/ft (1.08 m2 /m)
Shelf Area 4(Sq Ft/Ft) 2.76 ft2/ft (0.84 m2 /m)
1 Computed using ARI 1200 standard methodology: Refrigerated Volume, ft
3[m3
]/Unit of Length, ft [m]
2 ARI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume/Unit of Length, ft
3
/ft [m3/m]
3
Computed using ARI 1200 standard methodology: Total Display Area, ft2[m2]/Unit of Length, ft [m]
4
Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann Product Reference Guide. The standard shelf complement for this model is NONE.
ESTIMATED SHIPPING WEIGHT
5
Case Solid End
4 ft 6 ft 8 ft 12 ft (each)
lb (kg) 600 (272) 700 (318) 1100 (499) 1200 (545) 100 (45)
5
Actual weights will vary according to optional kits included.
Page 6
6 of 7 ES1S Technical Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
120V NEUTRAL
MAROON
BAND
120V POWER
W
B
G
N.E.C.
TAGS
MAROON
BAND
BROWN BAND
Fans
BROWN BAND
120V POWER
2
120V NEUTRAL
Electric Service Receptacle
Fans
Purple BAND
Heaters
Purple BAND
120V POWER
120V NEUTRAL
5
Heater Switch
Heaters
Defrost Termination Thermostat
Refrigeration Thermostat
To Condensing Unit
}
(Field Installed)
3
4
DB
DB
LB LB
BROWN BAND
Fans
BROWN BAND
120V POWER
120V NEUTRAL
1
Fans
R = Red G = Green BL = Blue LB = Light Blue DB = Dark Blue B = Black W = White
= 120V P
OWER = 120V NEUTRAL = Field GROUND
= Case GROUND
Fan Wiring
Offtime Defrost
Receptacles
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
Circled Numbers = Parts List Item Numbers
Grayed components in 12 foot models only.
Ambient Fan
Wiring
Glass Air Wipe
Ambient Heater
Wiring
4 ft case has 2 Heaters 6 ft case has 4 Heaters 8 ft case has 4 Heaters 12 ft case has 6 Heaters
4 ft case has 2 Fans 6 ft case has 4 Fans 8 ft case has 4 Fans 12 ft case has 6 Fans
4 ft case has 1 Fan 6 ft case has 2 Fans 8 ft case has 2 Fans 12 ft case has 3 Fans
Page 7
7 of 7
P/N 0506801_A
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Optional Lighting: 1 Row Ledge or 1 Row Rail
Light Circuits
Standard Lighting 2 Rows Canopy
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
= 120V POWER = 120V NEUTRAL
Grayed components in 12 foot models only.
R = Red Y = Yellow G = Green BL = Blue B = Black W = White
C
IRCLED NUMBERS = PARTS LIST ITEM NUMBERS
120V NEUTRAL
ORANGE OR TAN BAND
W
Light
Switch
120V POWER
ORANGE OR TAN B
AND
B
B
W
BL
R
R
BL
BL
6
BL
R
R
BL
BL
6
7
7
120V NEUTRAL
ORANGE OR TAN BAND
W
Light
Switch
120V POWER
ORANGE OR TAN B
AND
B
BL
R
R
BL
BL
6
R
R
R
7
7
7
7
7
7
7
Loading...