Hussmann EDS1 Technical Data Sheet

Page 1
P/N 0431326_A
Merchandisers
®
T'Stat Bulb
Location
(Optional
D
C
F
(Optional
A
A
E
B
E
EDS1
Technical Data Sheet
P/N 0431326_A
NSF
®
Certified
July 2007
Note: Changed items have been underlined.
©2007 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
Item Part # Description Wiring Item #
FAN ASSEMBLIES AND THERMOSTATS
A. 4W Fan Assemblies (1)
0392457 Fan Motor, Evaporator
(MO.4410101)
0409511 Fan Blade (FB.0409511)
embossing toward motor
0404551 Fan Motor, Ambient (2)
(MO.0404551)
B. 0382028 Standard Non-adjustable (3)
disc type Defrost Thermostat (CT.0382028)
C. 0137880 Optional Adjustable (4)
Refrigeration Thermostat (CT.4481084)
Item Part # Description Wiring Item #
L
AMPS AND BALLASTS
D. 0355716 Ballast, Electronic
2 lamps (BA.0355716) (5)
0355398 Ballast, Electronic
3 lamps (BA.4480118) (6)
E. Fluorescent Lamp (7)
Replace with like fixtures
H
EATERS
F. 0496496 Nosing Anti-sweat (8)
Heater, 4 ft (HE.4850738)
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
Page 2
EDS1 Technical Data Sheet
2 of 6
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Engineering
Plan Views
Self-Service
Glass Front
Delicatessen
Models
06-2003
A
Front
Refrigeration
Outlet
Water Seal
Waste Outlet
Electrical
EDS1
25 5/8
(651)
C
L
Legs
(See Note**)
(See Note***)
Leg Center Lines
C
D
B
E
3 5/8 (92)
25 5/8
(651)
28 3/4
(730)
33 3/8
(848)
44 5/8
(1133)
46
(1168)
Dimensions shown as inches and (mm).
4 ft 8 ft 12 ft
General
(A) Length of Case* 72 1/4 (1835) 96 1/4 (2444) 144 1/2 (3670)
*Each End and Partition adds 1 1/
2 inches (38 mm.) to the length of the lineup.
Maximum outside dimensions of case back to front 46 (1168) 46 (1168) 46 (1168) (includes bumper and Rear Sill) Back of case to front of splashguard 33
3
/
8 (848) 33
3
/
8 (848) 33
3
/
8 (848)
Center of rear legs to center of front legs 25
5
/
8 (651) 25
5
/
8 (651) 25
5
/
8 (651)
Electrical Service
(B) Righthand end of case to right edge of electrical raceway 7 (178) 7 (178) 7 (178) (C) Righthand end of case to left edge of electrical raceway 44
1
/2 (1131) 44 1/2 (1131) 44 1/2 (1131)
Back outside of case to center of knockout 3 5/8 (92) 3 5/8 (92) 3 5/8 (92) **Note: Electrical Field Wiring Connection Point
Waste Outlet
(D) Right end of case to center of waste outlet 24 (611) 24 (611) 72 1/4 (1835)
Left end of case to center of waste outlet 48 1/4 (1835) 72 1/4 (1835) 72 1/4 (1835) Back outside of case to center of waste outlet 25 5/8 (652) 25 5/8 (652) 25 5/8 (652)
Water Seal
Edge of water seal to center of waste outlet 4 (102) 4 (102) 4 (102) Outside diameter of drip pipe lines 1 1/2 (38) 1 1/2 (38) 1 1/2 (38) ***Note: Field installed water seal outlets, tees, and connectors are shipped with the merchandiser.
Refrigeration Outlet
(E) Right end of case to center of refrigeration outlet 9 3/8 (238) 9 3/8 (238) 9 3/8 (238)
Back of case to center of refrigeration outlet 28 3/4 (730) 28 3/4 (730) 28 3/4 (730) Outside diameter of the liquid line
3
/8 (9.5)
3
/8 (9.5)
3
/8 (9.5)
Outside diameter of the suction line
5
/8 (16)
5
/8 (16)
5
/8 (16)
Page 3
Impact EDS1
Delicatessen
Dimensions shown in inches & (mm).
REFRIGERATION DATA
Note: This data is based on store
temperature and humidity that does not exceed 75°F and 55% R.H.
EDS1 Discharge Air (°F) 24 Evaporator(°F) 14 Unit Sizing (°F) 12
Btu/hr/ft* EDS1 Parallel 390 Conventional 420
DEFROST DATA
EDS1 Frequency (hr) 12 Defrost Water (lb/ft/day) 0.20 (± 15% based on case configuration and
product loading).
O
FFTIME
EDS1 Temp Term (°F) 43°F Failsafe minutes 90
E
LECTRIC OR GAS
Not Recommended
Standard Defrost Thermostat
Close on rise: close 43°F – open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control
EDS1 CI/CO* 7
°F / -3°F
Indoor Unit Only, Pressure Defrost Termination* 43°F
*Use a Temperature Pressure Chart to determine PSIG conversions.
PHYSICAL DATA
EDS1 Merchandiser Drip Pipe (in.) 1
1
/2
Liquid Line (in.)
3
/8
Suction Line (in.)
5
/8
Estimated Charge (lb)** 4 ft 1.0 8 ft 1.5 12 ft 2.0
**This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound.
Length Added to Lineup by: Each
Plastic End w/ Bumper (in.) 3
1
/2
Each End/Partition (in.) 1 1/2
Self Service Glass, 1 Display Level
3 of 6
P/N 0431326_A
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
NSF Certification
These merchandisers are manufactured to meet ANSI /National Sanitation Foundation (NSF ®) Standard #7 requirements.
EDS1
22 1/
(572)
12 1/
(308)
O
DA
8
33 5/
(854)
8
7 3/
(308)
8
34
13 3/
(349)
(864)
4
33 3/
(289)
8
28 3/
25 5/
8
4
(849)
COIL
(651)
8
(730)
Electrical
3 5/
(92)
8
44 5/
46
FAN
11 3/
(1133)
8
(1168)
Refrigeration
Outlet
2
18 1/
2
(470)
FAN
Page 4
EDS1 Technical Data Sheet
4 of 6
Impact EDS1
Delicatessen
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Electrical Data
Number of Fans 4 ft 8 ft 12 ft
Refrigeration – 4W 2 2 3
Ambient Air Wipe — 15W 4 4 6
Export — 9W 4 2 3
Amperes Watts
Merchandiser 6 ft 8 ft 12 ft 6 ft 8 ft 12 ft
Fans (Refrigeration)
120V 60Hz Standard 0.62 0.52 0.78 48 36 54
120V 60Hz Energy Efficient NA NA NA NA NA NA
230V 50Hz Export NA 0.60 0.90 NA 96 144
Fans (Ambient Air Wipe)
Two-pole Muffin Fan 1.04 0.76 1.14 60 60 180
120V 60Hz Energy Efficient NA NA NA NA NA NA
230V 50Hz Export NA 0.36 0.54 NA 60 180
Constant on Anti-sweat Heaters 0.22 0.26 0.40 26 31 48
Cycling Anti-sweat Heaters 0.22 NA NA 26 NA NA
Minimum Circuit Ampacity
120V 60Hz Standard Fans 2.08 1.61 2.39
120V 60Hz Energy Efficient Fans NA NA NA
230V 50Hz Export Fans NA 1.17 1.72
Maximum Over Current Protection 120V 20 20 20
230V 50Hz Export 15 15 15
Optional Lighting*
Optional Interior Front Rail 0.40 0.51 0.77 46 59 85
Optional Ledge Lighting 0.4 0.51 0.77 46 59 85
Page 5
5 of 6
P/N 0431326_A
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
R = Red G = Green BL = Blue LB = Light Blue DB = Dark Blue B = Black W = White
= 120V P
OWER = 120V NEUTRAL = Field GROUND
= Case GROUND
Fan Wiring
Offtime Defrost
Fans
Electric Service Receptacle
Receptacles
120V N
EUTRAL
MAROON
BAND
120V P
OWER
W
B
G
N.E.C.
TAGS
MAROON
BAND
Defrost Termination Thermostat
Refrigeration
Thermostat
To Condensing Unit
}
(Field Installed)
3
4
BROWN BAND
Fans
BROWN BAND
120V POWER
120V NEUTRAL
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
Circled Numbers = Parts List Item Numbers
Grayed components in 12 foot models only.
1
8 ft case has 2 Fans
12 ft case has 3 Fans
BROWN BAND
Fans
BROWN BAND
120V POWER
120V NEUTRAL
2
Ambient Fan
Wiring
Glass Air Wipe
Fans
8 ft case has 4 Fans
12 ft case has 6 Fans
DB
DB
LB LB
Anti-sweat Heaters
8
Page 6
EDS1 Technical Data Sheet
6 of 6
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Light Circuits
120V NEUTRAL
120V POWER
ORANGE OR TAN BAND
ORANGE OR TAN BAND
Light
Switch
B
Optional
Rail Light Circuit
Optional Ledge
Light Circuit
G
W
B
BL
5
BL
R
BL
G
BG
W
BL
G
R
7
G
BL
R
77
5
BL
R
BL
G
BL
G
R
7
G
R
77
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
Circled Numbers = Parts List Item Numbers Grayed components in 12 foot models only.
R = Red G = Green BL = Blue B = Black W = White
= 120V P
OWER = 120V NEUTRAL = Field GROUND
= Case GROUND
Loading...