HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
P/N 0454041
Item Part # Description Wiring Item #
F
AN ASSEMBLIES, AND THERMOSTATS
A. 4W Fan Assemblies (1)
0404551 Fan Motor, Ambient
Item Part # Description Wiring Item #
L
AMPS AND
BALLASTS
B. 0355398 Ledge Lamps (2)
Electronic 3-Lamp
Ballast (Optional)
C. Fluorescent Lamp (3)
Replace with like fixtures
ED1C-ICE
Data Sheet Set
P/N 0454041
July, 2003
Note: Changed items have been underlined.

ED1C-ICE Data Sheet
2 of 5
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Engineering
Plan Views
Delicatessen
Curved Glass
Models
07-2003
C
L
(See Note**)
25 5/
8
(651)
Legs
Front
Refrigeration
Outlet
Water Seal
Waste Outlet
Leg Center Lines
Electrical
3 5/
8
(92)
(See Note***)
ED1C-ICE
A
D
C
B
25
5
/
8
(651)
28
3
/
4
(730)
33
3
/
8
(849)
44
5
/
8
(1133)
46
(1168)
E
Dimensions shown as inches and (mm).
6 ft 8 ft 12 ft
General
(A) Length of Case* 72 1/4 (1835) 96 1/4 (2444) 144 1/2 (3670)
*Each End and Partition adds 1 1/2 inches (38 mm.) to the length of the lineup.
Maximum outside dimensions of case back to front 46 (1333) 46 (1168) 46 (1168)
(includes bumper and Rear Sill)
Back of case to front of splashguard 33 3/8 (848) 33 3/8 (848) 33 3/8 (848)
Center of rear legs to center of front legs 25 5/
8 (651) 25
5
/
8 (651) 25
5
/
8 (651)
Electrical Service
(B) Righthand end of case to right edge of electrical raceway 7 (178) 7 (178) 7 (178)
(C) Righthand end of case to left edge of electrical raceway 44
1
/
2 (1131) 44
1
/
2 (1131) 44
1
/
2 (1131)
Back outside of case to center of knockout 3
5
/8 (92) 3 5/8 (92) 3 5/8 (92)
**Note: Electrical Field Wiring Connection Point
Waste Outlet
(D) Right end of case to center of waste outlet 24 (611) 24 (611) 72 1/4 (1835)
Left end of case to center of waste outlet 48 1/
4 (1835) 72
1
/
4 (1835) 72
1
/
4 (1835)
Back outside of case to center of waste outlet 25
5
/
8
(652) 25
5
/
8
(652) 25
5
/
8
(652)
WaterSeal
Edge of water seal to center of waste outlet 4 (102) 4 (102) 4 (102)
Outside diameter of drip pipe lines 1
1
/2 (38) 1 1/2 (38) 1 1/2 (38)
***Note: Field installed water seal outlets, tees, and connectors are shipped with the merchandiser.
Refrigeration Outlet
(E) Right end of case to center of refrigeration outlet 9 3/
8 (238) 9
3
/
8 (238) 9
3
/
8 (238)
Back of case to center of refrigeration outlet 28
3
/4 (730) 28 3/4 (730) 28 3/4 (730)
Outside diameter of the liquid line
3
/8 (9.5)
3
/8 (9.5)
3
/8 (9.5)
Outside diameter of the suction line
5
/
8 (16)
5
/
8 (16)
5
/