Hussmann ED1C-ICE Datasheet

Page 1
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
P/N 0454041
Item Part # Description Wiring Item # F
AN ASSEMBLIES, AND THERMOSTATS
A. 4W Fan Assemblies (1)
0404551 Fan Motor, Ambient
®
B
C
A
Item Part # Description Wiring Item # L
AMPS AND
BALLASTS
B. 0355398 Ledge Lamps (2)
Electronic 3-Lamp Ballast (Optional)
C. Fluorescent Lamp (3)
Replace with like fixtures
ED1C-ICE
Data Sheet Set
P/N 0454041
July, 2003
Note: Changed items have been underlined.
Page 2
ED1C-ICE Data Sheet
2 of 5
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Engineering
Plan Views
Delicatessen
Curved Glass
Models
07-2003
C
L
(See Note**)
25 5/
8
(651)
Legs
Front
Refrigeration
Outlet
Water Seal
Waste Outlet
Leg Center Lines
Electrical
3 5/
8
(92)
(See Note***)
ED1C-ICE
A
D
C
B
25
5
/
8
(651)
28
3
/
4
(730)
33
3
/
8
(849)
44
5
/
8
(1133)
46
(1168)
E
Dimensions shown as inches and (mm).
6 ft 8 ft 12 ft
General
(A) Length of Case* 72 1/4 (1835) 96 1/4 (2444) 144 1/2 (3670)
*Each End and Partition adds 1 1/2 inches (38 mm.) to the length of the lineup. Maximum outside dimensions of case back to front 46 (1333) 46 (1168) 46 (1168) (includes bumper and Rear Sill) Back of case to front of splashguard 33 3/8 (848) 33 3/8 (848) 33 3/8 (848) Center of rear legs to center of front legs 25 5/
8 (651) 25
5
/
8 (651) 25
5
/
8 (651)
Electrical Service
(B) Righthand end of case to right edge of electrical raceway 7 (178) 7 (178) 7 (178) (C) Righthand end of case to left edge of electrical raceway 44
1
/
2 (1131) 44
1
/
2 (1131) 44
1
/
2 (1131)
Back outside of case to center of knockout 3
5
/8 (92) 3 5/8 (92) 3 5/8 (92)
**Note: Electrical Field Wiring Connection Point
Waste Outlet
(D) Right end of case to center of waste outlet 24 (611) 24 (611) 72 1/4 (1835)
Left end of case to center of waste outlet 48 1/
4 (1835) 72
1
/
4 (1835) 72
1
/
4 (1835)
Back outside of case to center of waste outlet 25
5
/
8
(652) 25
5
/
8
(652) 25
5
/
8
(652)
WaterSeal
Edge of water seal to center of waste outlet 4 (102) 4 (102) 4 (102) Outside diameter of drip pipe lines 1
1
/2 (38) 1 1/2 (38) 1 1/2 (38)
***Note: Field installed water seal outlets, tees, and connectors are shipped with the merchandiser.
Refrigeration Outlet
(E) Right end of case to center of refrigeration outlet 9 3/
8 (238) 9
3
/
8 (238) 9
3
/
8 (238)
Back of case to center of refrigeration outlet 28
3
/4 (730) 28 3/4 (730) 28 3/4 (730)
Outside diameter of the liquid line
3
/8 (9.5)
3
/8 (9.5)
3
/8 (9.5)
Outside diameter of the suction line
5
/
8 (16)
5
/
8 (16)
5
/
8 (16)
Page 3
ED1C-ICE
Refrigeration
Outlet
Electrical
FAN
DA
O
18
(457)
22 1/2
(572)
113/8
(289)
35/8
(92)
133/4
(349)
34
(864)
25 5/8
(651)
28 3/4
(730)
33 3/8
(849)
44 5/8
(1133)
46
(1168)
341/2
(875)
7 3/4
(196)
Impact
ED1C-ICE
Delicatessen
Dimensions shown in inches & (mm).
REFRIGERATION DATA
Note: This data is based on store
temperature and humidity that does not exceed 75°F and 55% R.H.
ED1C Discharge Air (°F) 24 Evaporator(°F) 22 Unit Sizing (°F) 20
Btu/hr/ft* ED1C Parallel 150 Conventional 155
*For all refrigeration equipment other than Hussmann, use conventional Btu values.
DEFROST DATA
ED1C Frequency (hr) 24 Defrost Water(lb/ft/day) NA (± 15% based on case configuration and
product loading).
OFFTIME ED1C
T emp Term (°F) 70°F Failsafe minutes 90
E
LECTRIC OR GAS Not Recommended
Standard Defrost Thermostat N/A
CONVENTIONALCONTROLS
Low Pressure Backup Control
ED1C CI/CO** 28°F / 1°F
Indoor Unit Only, Pressure Defrost Termination** N/A
**Use a Temperature Pressure Chart to determine PSIG conversions.
PHYSICALDATA
ED1C Merchandiser Drip Pipe (in.) 1
1
/2
Liquid Line (in.)
3
/8
Suction Line (in.)
5
/8
Estimated Charge (lb)*** 12 ft 1.0
***This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound.
Length Added to Lineup by: Each
Plastic End w/ Bumper (in.) 3
1
/2
Each End/Partition (in.) 1 1/2
NOTE: The bumper is 4 inches wide. Center of the bumper is
18 1/2(470 mm.) inches from the floor.
Self Service Glass, Serpentine Coil, 1 Display Level
3 of 5
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
P/N 0454041
Page 4
ED1C-ICE Data Sheet
4 of 5
Impact ED1C-ICE
Delicatessen
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Electrical Data
Number of Fans 12 ft Ambient AirWipe — 15W 6
Amperes Watts Merchandiser 12 ft 6 ft 12 ft Fans (Refrigeration) NA NA
Fans (Ambient AirWipe)
Standard (120V 60Hz) 1.56 60 90 Export (230V 50Hz) NA NA NA
Minimum Circuit Ampacity 1.76
Maximum Over Current Protection 120V 20
Optional Lighting*
Optional Ledge Lighting 0.71 85
*230V lighting values are under review.
Page 5
5 of 5
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
P/N 0454041
R = Red G = Green BL = Blue LB = Light Blue DB = Dark Blue B = Black W = White
= 120V P
OWER = 120V NEUTRAL = Field GROUND
= Case GROUND
Electric Service Receptacle
Receptacles
120V N
EUTRAL
MAROON
BAND
120V P
OWER
W
B
G
N.E.C. TAGS
MAROON
BAND
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
Circled Numbers = Parts List Item Numbers
BROWN BAND
Fans
BROWN BAND
120V POWER
120V NEUTRAL
1
Ambient Fan
Wiring
Glass Air Wipe
Fans
12 ft case has 6 Fans
W
BG
R
R
BL
BL
R
BL
BL
G
G
G
2
33
3
Optional Ledge
Light Circuit
Light Circuits
Loading...