8 ft 12 ft
General
(A) Case Length (without ends or partitions) 96 1/4 (2445) 144 3/8 (3667)
(Each end and insulated partition adds 1 in. (25 mm) to case line up.)
Maximum O/S dimension back to front (with bumper) 46 1/2 (1181) 46 1/2 (1181)
Back of case to front of front panel 34 1/2 (876) 34 1/2 (876)
Back of case to O/S edge of front skid rail 29 3/
8 (746) 29
3
/
8 (746)
Width of skid rail 4
1
/
2 (114) 4
1
/
2 (114)
RH end of case to outside edge of external support 1
3
/8 (34) 1 3/8 (34)
Distance between edges of
external support and center support 40 1/
2 (1029) 40
1
/
2 (1029)
Distance between edges of center supports NA 44 (1118)
Stub-up area between front skid rail and front panel 5
3
/4 (146) 5 3/4 (146)
Electrical Service (Electrical Field Wiring connection point)
(B) Length of electrical raceway 37 (940) 37 (940)
(C) RH End of case to center of farthest knockout 84 3/4 (2153) 132 3/4 (3372)
Back of case to center of end knockout 29 5/8 (752) 29 5/8 (752)
(D) RH End of case to RH end of wireway 57 1/
4 (1454) 105
1
/
8 (2670)
LH End of case to LH end of wireway 2
1
/8 (54) 2 1/8 (54)
Waste Outlet
(E) RH End of case to the center of waste outlet 24 1/2 (622) 72 1/4 (1834)
LH End of case to the center of waste outlet 71 3/4 (1822) 72 1/8 (1832)
Back O/S of case to center of waste outlet 27 5/
8 (702) 27
5
/
8 (702)
Water Seal
Edge of water seal to center of waste outlet 4 (102) 4 (102)
Schedule 40
diameter of the drip pipe 1 1/2 (38) 1 1/2 (38)
NOTE: Water seal outlet must clear front skid rail; water seal rotation in forward direction only due to low base.
Refrigeration Outlet
Back of case to center of refrigeration outlet 30 3/
4 (781) 30
3
/
4 (781)
RH end of case to center of refrigeration outlet 8
3
/
8 (213) 8
3
/
8 (213)
2 of 8 E3XC Technical Data Sheet
U.S. & Canada 1-800-922-1919 • Mexico 1-800-522-1900
Engineering
Plan Views
Dimensions shown as inches and (mm).
04-2010