Hussmann E3S Specifications

Page 1
B
D
D
E
C
E
A
P/N0504418B
Item Part # Description Wiring Item #
FAN
ASSEMBLIES AND THERMOSTATS
A. 7W Standard Fan Assembly (1)
(MO.4410102)
0142780 Fan Blade (FB.0142780)
embossing toward motor
7W Energy Efficient Fan Assembly 0477654
Fan Motor, Evaporator (MO.4410545)
0142780 Fan Blade (FB.0142780)
embossing toward motor
B. 0411744 Standard Non-adjustable (2)
Defrost Thermostat (CT.0411744)
C. Optional Adjustable Refrigeration Thermostat (3)
Item Part # Description Wiring Item #
L
AMPS AND BALLASTS
D. Ballast, Electronic
0466234 2 lamps (BA.4480823) (4) 0466235 3 lamps (BA.4480901) 0466236 4 lamps (BA.4481095)
E. Fluorescent Lamp (5)
Replace with like fixtures
E3S
Technical Data Sheet
P/N 0504418_B
NSF
®
Certified
April 2010
©2010 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
Note: Revision B removes 4 ft, adds Btu note on page 3, revises load limit line on page 8 and updates pages 1, 2, 4 & 5. Changes are underlined, circled or marked with a vertical line in the margin.
Page 2
6 ft 8 ft 12 ft
General
(A) Case Length (without ends or partitions) 72 1/8 (1832) 96 1/4 (2445) 144 3/8 (3667)
NOTE: Each end or insulated partition adds 1 inch to lineup.
Maximum O/S dimension back to front (with bumper) 46 1/
2 (1181) 46
1
/
2 (1181) 46
1
/
2 (1181)
Back of case to front of front panel 34
1
/2 (876) 34 1/2 (876) 34 1/2 (876) Back of case to O/S edge of front skid rail 29 3/8 (746) 29 3/8 (746) 29 3/8 (746) Width of skid rail 4 1/
2 (114) 4
1
/
2 (114) 4
1
/
2 (114)
RH end of case to outside edge of external support 1
3
/
8 (34) 1
3
/
8 (34) 1
3
/
8 (34)
Distance between edges of
external support and center support 28
1
/
2 (724) 40
1
/
2 (1029) 40
1
/
2 (1029)
Distance between edges of center supports NA NA 44 (1118) Stub-up area between front skid rail and front panel 5
3
/4 (146) 5 3/4 (146) 5 3/4 (146)
Electrical Service (Electrical Field Wiring connection point)
(B) Length of electrical raceway 18
3
/
8 (467) 37 (940) 37 (940)
(C) RH End of case to center of farthest knockout 60
3
/
4 (1543) 84
3
/
4 (2153) 132
3
/
4 (3372)
Back of case to center of end knockout 29
5
/8 (752) 29 5/8 (752) 29 5/8 (752)
(D) RH End of case to RH end of wireway 51 5/8 (1311) 57 1/4 (1454) 105 1/8 (2670)
LH End of case to LH end of wireway 2 1/8 (54) 2 1/8 (54) 2 1/8 (54)
Waste Outlet
(E) RH End of case to the center of waste outlet 24
1
/4 (616) 24 1/2 (622) 72 1/4 (1834) LH End of case to the center of waste outlet 47 7/8 (1216) 71 3/4 (1822) 72 1/8 (1832) Back O/S of case to center of waste outlet 27 5/8 (702) 27 5/8 (702) 27 5/8 (702)
Water Seal
Edge of water seal to center of waste outlet 4 (102) 4 (102) 4 (102) Schedule 40
diameter of the drip pipe 1 1/2 (38) 1 1/2 (38) 1 1/2 (38)
NOTE: Water seal outlet must clear front skid rail; water seal rotation in forward direction only due to low base.
Refrigeration Outlet
Back of case to center of refrigeration outlet 30
3
/4 (781) 30 3/4 (781) 30 3/4 (781) RH end of case to center of refrigeration outlet 8 3/
8 (213) 8
3
/
8 (213) 8
3
/
8 (213)
2 of 8 E3S Technical Data Sheet
Engineering
Plan Views
Dimensions shown as inches and (mm).
04-2010
E3S
Delicatessen
Precut & Packaged
Produce
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/2 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
7
/8
U.S. & Canada 1-800-922-1919 • Mexico 1-800-522-1900
A
C
D
B
Electrical Service
1
2
/8
(54)
29 5/8
(752)
Waste Outlet
C
L
Water Seal
E
27 5/8
(702)
8 3/8 (213)
30 3/4
(781)
34 1/2
(876)
Front
46 1/2
(1182)
Page 3
3 of 8
P/N 0504418_B
20 3/8
(518)
30
(762)
54
(1372)
12
(305)
18 1/2
(470)
34 1/2
(876)
46 1/2
(1182)
12
(305)
27 5/8
(702)
30 3/4
(781)
31 (787)
FAN
C O
I
L
34
(864)
4 1/4
(108)
Refrigeration Outlet
E3S
Impact
Elite
E3S
Delicatessen
Precut & Packaged Produce
Elite Specialty Merchandiser Multi-deck, 3 Display Levels
Dimensions shown as inches & (mm).
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.
See Page 8 for recommended shelf configuration.
REFRIGERATION DATA
Note: This data is based on store temperature
and humidity that does not exceed 75 (°F) and 55% R.H.
E3S
Discharge Air (°F) 29
Evaporator (°F) 21
Unit Sizing (°F) 19
Btu/hr/ft‡— Unlit Shelves‡‡E3S
Parallel 1180
Conventional 1280
Optional energy efficient motors reduce the
refrigeration load by 21 Btu/hr/ft.
‡‡
Add 20 Btu/hr/ft per shelf row for
fluorescent lamps.
DEFROST DATA
E3S
Frequency (hr) 6
Defrost Water (lb/ft/day)8
(± 15% based on case configuration and
product loading).
OFFTIME E3S
Temp Term (°F) 48
Failsafe (minutes) 40
ELECTRIC OR GAS Not Recommended
Standard Defrost Thermostat
Close on rise: close 48°F – open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control
CI/CO
* E3S
Temp (°F) 14 / 4
Indoor Unit Only, Pressure Defrost Termination (Temp °F)
* 48°F
*Use a Temperature Pressure Chart to determine PSIG conversions.
Estimated Charge ** E3S
6 ft 1.8 lb 29 oz 0.8 kg
8 ft 1.9 lb 30 oz 0.9 kg
12 ft 2.9 lb 46 oz 1.3 kg
**This is an average for all refrigerant types actual refrigerant charge may vary by approximately half a pound.
Page 4
4 of 8 E3S Technical Data Sheet
U.S. & Canada 1-800-922-1919 • Mexico 1-800-522-1900
Impact
Elite
E3S
Delicatessen Precut & Packaged Produce
Electrical Data
6 ft 8 ft 12 ft
Number of Fans—7W 2 2 3
Amperes Watts
6 ft 8 ft 12 ft 6 ft 8 ft 12 ft
Evaporator Fan
120V 60Hz Standard 1.00 1.00 1.50 78 78 117
120V 50Hz Standard 1.10 1.10 1.65 84 84 126
230V 60Hz Export N
A
230V 50Hz Export NA
120V 60Hz Energy Efficient 0.38 0.38 0.57 28 28 42
230V 60Hz Energy Efficient NA
Cycling Anti-sweat Heaters NA
Minimum Circuit Ampacity
120V 60Hz Standard 1.20 1.20 1.70
120V 50Hz Standard 1.30 1.30 1.85
230V 60Hz Export N
A
230V 50Hz Export N
A
120V 60Hz Energy Efficient 0.58 0.58 0.77
230V 60Hz Energy Efficient N
A
Maximum Over Current Protection 120V 20 20 20 Maximum Over Current Protection 230V N
A
208V Electric Defrost Heaters NA
Standard Lighting (T-8 fluorescent)
2 Rows of Canopy 1.01 1.01 1.52 122 122 183
Optional Lighting (T-8 fluorescent)
1 Row of Rail Lights 0.51 0.51 0.76 62 62 96
1 Row of Ledge Lights 0.51 0.51 0.76 62 62 96
Optional Shelf Lighting (T-8 fluorescent)
1 Row of Shelves 0.51 0.51 0.76 62 62 96
2 Rows of Shelves 1.01 1.01 1.52 122 122 183
3 Rows of Shelves 1.53 1.53 2.28 184 184 274
120V Lighting Circuit Total = Standard Lighting + Total Optional Lighting + Optional Shelf Lighting
Page 5
Product Data
Recommended Usable Cube 1(Cu Ft/Ft) 4.58 ft3 /ft (0.43 m3/m) AHRI Total Display Area 2(Sq Ft/Ft) 3.02 ft2 /ft (0.92 m2 /m) Shelf Area 3(Sq Ft/Ft) 7.08 ft2 /ft (2.16 m2 /m)
1 AHRI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume / Unit of Length, ft
3
/ft [m3/m]
2
Computed using AHRI 1200 standard methodology: Total Display Area, ft2[m2] / Unit of Length, ft [m]
3
Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann Product
Reference Guide. The standard shelf complement for this model is (1) row of 14-inch shelf, (1) row of 18-inch shelf and (1) row of 22-in shelf.
5 of 8
P/N 0504418_B
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
ESTIMATED SHIPPING WEIGHT
4
Case Solid End
6 ft 8 ft 12 ft (each)
lb (kg) 600 (272) 800 (363) 1000 (454) 100 (45)
4
Actual weights will vary according to optional kits included.
Impact
Elite
E3S
Delicatessen
Precut & Packaged Produce
Page 6
6 of 8 E3S Technical Data Sheet
Defrost
Termination
Thermostat
Refrigeration
Thermostat
Dark Blue
3
To Condensing Unit
}
Light Blue
2
2 & 3 Fans
120V NEUTRAL
B
ROWN BAND
120V POWER
Fans
1
B
ROWN BAND
U.S. & Canada 1-800-922-1919 • Mexico 1-800-522-1900
5
Connector
Connector
G
R
BL
R
G
G
5
Connector
120 V
Power
BK
W
G
BL
BL
BL
G
W
BL
Shelf Light Circuits
4
W
BL
R
G
G
R
R
R
G
R
BL
BL
Connector
Connector
G
Connector
Connector
G
R
BL
BL
G
BL
Connector Connector
Optional Shelf Harness and Light Circuits for One Row of Shelves
Shelf Harness
5
R
G
BK
BK
Fan Wiring Offtime Defrost
Shelf Lighting
All components must have mechanical ground, and the merchandiser must be grounded.
R = Red Y = Yellow G = Green BL = Blue BK = Black W = White
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
Grayed components in 12 foot models only
= 120VPOWER = 120V NEUTRAL = FIELD GROUND
WARNING
= CASE GROUND
Page 7
Standard Lighting 2 Rows Canopy
7 of 8
P/N 0504418_B
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Light Circuits
120V NEUTRAL
ORANGE OR TAN BAND
120V POWER
ORANGE OR TAN
AND
B
BK
Light
Switch
BK
W
4
W
4
BL
R
BL
R
BL
BL
5
BL
5
R
5
BL
R
5
R
5
R
5
Optional Lighting: 1 Row Ledge or 1 Row Rail
120V NEUTRAL
ORANGE OR TAN BAND
120V POWER
All components must have mechanical ground, and the merchandiser must be grounded.
ORANGE OR TAN
AND
B
Light
Switch
BK
W
4
R
BL
BL
55
WARNING
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
Grayed components in 12 foot models only
R = Red Y = Yellow G = Green BL = Blue BK = Black W = White
BL
R
R
5
= 120VPOWER
= 120V NEUTRAL = FIELD GROUND
= CASE GROUND
Page 8
8 of 8 E3S Technical Data Sheet
U.S. & Canada 1-800-922-1919 • Mexico 1-800-522-1900
SHELF CONFIGURATION
This merchandiser is designed for three shelves.
This illustration shows recommended shelf depth and shelf angle for the three locations.
It is critical to case performance that no product, shelf or stop extend beyond the load limit, as shown in this illustration. This configuration supports the air curtain and provides optimal case performance.
Check with Hussmann engineering before using a different configuration.
Impact
Elite
E3S
Delicatessen Precut & Packaged Produce
Load Limit
ecommended
Angle
Shelf
Size
14 in.
18 in.
22 in.
Loading...