Item Part # Description Wiring Item #
FAN
ASSEMBLIES AND THERMOSTATS
A. 7W Standard Fan Assembly (1)
(MO.4410102)
0142780 Fan Blade (FB.0142780)
embossing toward motor
7W Energy Efficient Fan Assembly 0477654
Fan Motor, Evaporator (MO.4410545)
0142780 Fan Blade (FB.0142780)
embossing toward motor
B. 0411744 Standard Non-adjustable (2)
Defrost Thermostat (CT.0411744)
C. Optional Adjustable Refrigeration Thermostat (3)
Item Part # Description Wiring Item #
L
AMPS AND BALLASTS
D. Ballast, Electronic
0466234 2 lamps (BA.4480823) (4) 0466235 3 lamps (BA.4480901) 0466236 4 lamps (BA.4481095)
E. Fluorescent Lamp (5)
Replace with like fixtures
E3S
Technical Data Sheet
P/N 0504418_B
NSF
®
Certified
April 2010
©2010 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
Note: Revision B removes 4 ft, adds Btu note on page 3, revises load limit line on page 8 and updates pages 1, 2, 4 & 5. Changes are underlined, circled or marked with a vertical line in the margin.
6 ft 8 ft 12 ft
General
(A) Case Length (without ends or partitions) 72 1/8 (1832) 96 1/4 (2445) 144 3/8 (3667)
NOTE: Each end or insulated partition adds 1 inch to lineup.
Maximum O/S dimension back to front (with bumper) 46 1/
2 (1181) 46
1
/
2 (1181) 46
1
/
2 (1181)
Back of case to front of front panel 34
1
/2 (876) 34 1/2 (876) 34 1/2 (876) Back of case to O/S edge of front skid rail 29 3/8 (746) 29 3/8 (746) 29 3/8 (746) Width of skid rail 4 1/
2 (114) 4
1
/
2 (114) 4
1
/
2 (114)
RH end of case to outside edge of external support 1
3
/
8 (34) 1
3
/
8 (34) 1
3
/
8 (34)
Distance between edges of
external support and center support 28
1
/
2 (724) 40
1
/
2 (1029) 40
1
/
2 (1029)
Distance between edges of center supports NA NA 44 (1118) Stub-up area between front skid rail and front panel 5
3
/4 (146) 5 3/4 (146) 5 3/4 (146)
Electrical Service (Electrical Field Wiring connection point)
(B) Length of electrical raceway 18
3
/
8 (467) 37 (940) 37 (940)
(C) RH End of case to center of farthest knockout 60
3
/
4 (1543) 84
3
/
4 (2153) 132
3
/
4 (3372)
Back of case to center of end knockout 29
5
/8 (752) 29 5/8 (752) 29 5/8 (752)
(D) RH End of case to RH end of wireway 51 5/8 (1311) 57 1/4 (1454) 105 1/8 (2670)
LH End of case to LH end of wireway 2 1/8 (54) 2 1/8 (54) 2 1/8 (54)
Waste Outlet
(E) RH End of case to the center of waste outlet 24
1
/4 (616) 24 1/2 (622) 72 1/4 (1834) LH End of case to the center of waste outlet 47 7/8 (1216) 71 3/4 (1822) 72 1/8 (1832) Back O/S of case to center of waste outlet 27 5/8 (702) 27 5/8 (702) 27 5/8 (702)
Water Seal
Edge of water seal to center of waste outlet 4 (102) 4 (102) 4 (102) Schedule 40
diameter of the drip pipe 1 1/2 (38) 1 1/2 (38) 1 1/2 (38)
NOTE: Water seal outlet must clear front skid rail; water seal rotation in forward direction only due to low base.
Refrigeration Outlet
Back of case to center of refrigeration outlet 30
3
/4 (781) 30 3/4 (781) 30 3/4 (781) RH end of case to center of refrigeration outlet 8 3/
8 (213) 8
3
/
8 (213) 8
3
/
8 (213)
2 of 8 E3S Technical Data Sheet
Engineering
Plan Views
Dimensions shown as inches and (mm).
04-2010
E3S
Delicatessen
Precut & Packaged
Produce
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/2 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
7
/8
U.S. & Canada 1-800-922-1919 • Mexico 1-800-522-1900
A
C
D
B
Electrical Service
1
2
/8
(54)
29 5/8
(752)
Waste Outlet
C
L
Water Seal
E
27 5/8
(702)
8 3/8 (213)
30 3/4
(781)
34 1/2
(876)
Front
46 1/2
(1182)
3 of 8
P/N 0504418_B
20 3/8
(518)
30
(762)
54
(1372)
12
(305)
18 1/2
(470)
34 1/2
(876)
46 1/2
(1182)
12
(305)
27 5/8
(702)
30 3/4
(781)
31 (787)
FAN
C O
I
L
34
(864)
4 1/4
(108)
Refrigeration Outlet
E3S
Impact
Elite
E3S
Delicatessen
Precut & Packaged Produce
Elite Specialty Merchandiser Multi-deck, 3 Display Levels
Dimensions shown as inches & (mm).
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.
See Page 8 for recommended shelf configuration.
REFRIGERATION DATA
Note: This data is based on store temperature
and humidity that does not exceed 75 (°F) and 55% R.H.
E3S
Discharge Air (°F) 29
Evaporator (°F) 21
Unit Sizing (°F) 19
Btu/hr/ft‡— Unlit Shelves‡‡E3S
Parallel 1180
Conventional 1280
Optional energy efficient motors reduce the
refrigeration load by 21 Btu/hr/ft.
‡‡
Add 20 Btu/hr/ft per shelf row for
fluorescent lamps.
DEFROST DATA
E3S
Frequency (hr) 6
Defrost Water (lb/ft/day)8
(± 15% based on case configuration and
product loading).
OFFTIME E3S
Temp Term (°F) 48
Failsafe (minutes) 40
ELECTRIC OR GAS Not Recommended
Standard Defrost Thermostat
Close on rise: close 48°F – open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control
CI/CO
* E3S
Temp (°F) 14 / 4
Indoor Unit Only, Pressure Defrost Termination (Temp °F)
* 48°F
*Use a Temperature Pressure Chart to determine PSIG conversions.
Estimated Charge ** E3S
6 ft 1.8 lb 29 oz 0.8 kg
8 ft 1.9 lb 30 oz 0.9 kg
12 ft 2.9 lb 46 oz 1.3 kg
**This is an average for all refrigerant types actual refrigerant charge may vary by approximately half a pound.