Hussmann E2SP Specifications

Page 1
D
F
E
A
G
B
C
E2SP
Data Sheet Set
P/N 0453525C
®
Certified
November 2009
Item Part # Description Wiring Item #
FAN ASSEMBLIES
A. 12W Fan Assembly (1)
0047000 Fan Motor, Evaporator
(MO.4410103)
0124150 Fan Blade (FB.0124150)
embossing toward motor
12W Energy Efficient Fan Assembly (1) 0477655 Fan Motor, Evaporator
(MO.4410546)
0124150 Fan Blade (FB.0124150)
embossing toward motor
B. 0458883 Fan, Optional Refrigerated (2)
Rear Storage (EV.4670919)
C. 0404551 Cavity Fan, Ambient (3)
(MO.0404551)
Item Part # Description Wiring Item #
THERMOSTATS
D. 0411744 Standard Non-adjustable (4)
Defrost Thermostat (CT.0411744)
E. 0353949 Optional Adjustable (5)
Refrigeration Thermostat (CT.4481087)
LAMPS AND BALLASTS
F. Ballast, Electronic (6)
0466234 2 lamps (BA.4480823) 0466235 3 lamps (BA.4480901) 0466236 4 lamps (BA.4481095)
G. Fluorescent Lamp (7)
Replace with like fixtures
S
HOWN WITH
OPTIONAL
REAR STORAGE
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
P/N0453525C
Note: Rev. C adds Aftermarket part numbers on page 1; Btu note on page 3; other changes are underlined.
©2009 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
Page 2
2 of 10 E2SP Technical Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
E2SP Meat, Delicatessen Precut & Packaged
Produce
Standard
Configuration
(without Optional
Rear Storage)
Front to back dimensions do not include optional rear storage dimension. 4 ft 6 ft 8 ft 12 ft
General
(A) Case Length (without ends or partitions) 48 1/
8 (1222) 72
1
/
8 (1832) 96
1
/
4 (2445) 144
3
/
8 (3667)
NOTE: Each end and insulated partition adds 1 inch to lineup.
Maximum O/S dimension back to front (with bumper) 47 (1194) 47 (1194) 47 (1194) 47 (1194) Back of case to front of front panel 35 (889) 35 (889) 35 (889) 35 (889) Back of case to O/S edge of front skid rail 29 3/4 (756) 29 3/4 (756) 29 3/4 (756) 29 3/4 (756) Width of skid rail 4 1/2 (114) 4 1/2 (114) 4 1/2 (114) 4 1/2 (114) RH end of case to outside edge of external support 1 3/
8 (35) 1
3
/
8 (35) 1
3
/
8 (35) 1
3
/
8 (35)
Distance between edges of
external support and center support NA 28
1
/2 (724) 40 1/2 (1029) 40 1/2 (1029) Distance between edges of center supports NA NA NA 44 (1118) Distance between edges of external supports 37 (940) NA NA NA Stub-up area between front skid rail and front panel 5 3/4 (146) 5 3/4 (146) 5 3/4 (146) 5 3/4 (146)
Electrical Service (Electrical Field Wiring connection point)
(B) Length of electrical raceway 36 1/8 (918) 26 5/8 (676) 36 1/8 (918) 36 1/8 (918)
RH End of case to center of farthest knockout 11 3/8 (289) 11 3/8 (289) 11 3/8 (289) 11 3/8 (289) Back of case to center of end knockout 6 3/8 (162) 6 3/8 (162) 6 3/8 (162) 6 3/8 (162)
(C) RH End of case to RH end of raceway 6 1/8 (156) 6 1/8 (156) 6 1/8 (156) 6 1/8 (156)
Waste Outlet
(D) RH End of case to the center of waste outlet 24 1/4 (616) 24 1/4 (616) 24 1/2 (622) 72 1/4 (1835) (E) LH End of case to the center of waste outlet 23 7/8 (606) 47 7/8 (1216) 72 3/4 (1848) 72 1/8 (1832)
Back O/S of case to center of waste outlet 28 1/8 (714) 28 1/8 (714) 28 1/8 (714) 28 1/8 (714)
Water Seal
Edge of water seal to center of waste outlet 4 (102) 4 (102) 4 (102) 4 (102) Outside diameter of the drip pipe 1 1/2 (38) 1 1/2 (38) 1 1/2 (38) 1 1/2 (38)
NOTE: Water seal outlet must clear front skid rail; water seal rotation in forward direction only due to low base.
Refrigeration Outlet
Back of case to center of refrigeration outlet 31 1/4 (794) 31 1/4 (794) 31 1/4 (794) 31 1/4 (794) RH end of case to center of refrigeration outlet 8 3/8 (213) 8 3/8 (213) 8 3/8 (213) 8 3/8 (213)
Engineering
Plan Views
Dimensions shown as inches and (mm).
10-2005
A
12 Ft Case
28 1/8
(714)
31 1/4
(794)
35
(889)
E
8 3/8 (213)
Front
Waste Outlet
Water Seal
B
C
Electrical
6 3/8
(162)
D
47
(1194)
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/2 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
7
/8
Page 3
REFRIGERATION DATA
Note: This data is based on store temperature and
humidity that does not exceed 75 (°F) and 55% R.H.
E2SP
Meat Deli
Discharge Air (°F) 25 28
Evaporator (°F) 18 21
Unit Sizing (°F) 16 19
Btu/hr/ft
E2SP
Parallel 900 890
Conventional 1000 980
with refrigerated rear storage, add 300 Btu/hr/ft
Optional energy efficient motors reduce the
refrigeration load by 21 Btu/hr/ft.
DEFROST DATA
E2SP
Frequency (hr) 6
Defrost Water 8 lb/ft/day
(± 15% based on case configuration and product
loading).
OFFTIME E2SP
Temp Term (°F) 48
Failsafe (minutes) 40
E
LECTRIC OR GAS
Not Recommended
Standard Defrost Thermostat
Close on rise: close 48°F – open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control CI/CO**
E2SP Meat Deli
Temp (°F) 11 / 6 14 / 4
Indoor Unit Only, Pressure Defrost
Termination (Temp °F)
** 48°F
**Use a Temperature Pressure Chart to determine
PSIG conversions.
Estimated Charge (lb)*** E2SP
4 ft 0.9
6 ft 1.8
8 ft 1.9
12 ft 2.9
***This is an average for all refrigerant types actual
refrigerant charge may vary by approximately half a
pound.
35
(889)
9 3/4 (248)
4 3/4
(121)
12
(305)
19 1/8
(486)
31
(787)
C
O
I
L
Refrigeration Outlet
E2SP
FAN
31 1/4
(794)
28 1/8
(714)
20
(508)
Standard Sneeze Guard
53 3/4
(1365)
47
(1194)
12
(305)
22
(559)
40 1/4
(1022)
Impact
Elite
E2SP
Meat, Delicatessen
Precut & Packaged Produce
Elite Specialty Merchandiser Multi-deck, Prep Top, 2 Display Levels
Dimensions shown as in. & (mm).
See Page 9 for shelf arrangement.
3 of 10P/N 0453525_C
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.
Page 4
E2SP
Meat, Delicatessen
Precut & Packaged
Produce
with Optional
Rear Storage —
Refrigerated or
Nonrefrigerated
4 of 10 E2SP Technical Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Engineering
Plan Views
Dimensions shown as inches and (mm).
10-2005
Ballast
Tray
Optional Unrefrigerated Rear Storage
12
(305)
Optional Refrigerated Rear Storage
16
(406)
8 Ft Case
28 1/8
(714)
35
(889)
D
8 3/8 (213)
Front
Waste Outlet
Water Seal
C
31 1/4
(794)
47
(1194)
63
(1600)
B
E
E
A
Front to back dimensions do not include optional rear storage dimension. 4 ft 6 ft 8 ft 12 ft
General
(A) Case Length (without ends or partitions) 48 1/8 (1222) 72 1/8 (1832) 96 1/4 (2445) 144 3/8 3667)
NOTE: Each end and insulated partition adds 1 inch to lineup.
Maximum O/S dimension back to front (with bumper) 47 (1194) 47 (1194) 47 (1194) 47 (1194) Back of case to front of front panel 35 (889) 35 (889) 35 (889) 35 (889) Back of case to O/S edge of front skid rail 29 3/
4 (756) 29
3
/
4 (756) 29
3
/
4 (756) 29
3
/
4 (756)
Width of skid rail 4
1
/
2 (114) 4
1
/
2 (114) 4
1
/
2 (114) 4
1
/
2 (114)
RH end of case to outside edge of external support 1
3
/8 (35) 1 3/8 (35) 1 3/8 (35) 1 3/8 (35)
Distance between edges of
external support and center support NA 28 1/
2 (724) 40
1
/
2 (1029) 40
1
/
2 (1029)
Distance between edges of center supports NA NA NA 44 (1118) Distance between edges of external supports 37 (940) NA NA NA Stub-up area between front skid rail and front panel 5
3
/
4 (146) 5
3
/
4 (146) 5
3
/
4 (146) 5
3
/
4 (146)
Electrical Service (Electrical Field Wiring connection point)
(B) RH End of case to LH end of connection box 42
1
/8 (1070) 42 1/8 (1070) 42 1/8 (1070) 91 3/8 (2321)
(E) Back of storage to NONREFRIGERATED STORAGE
CONNECTION BOX
, center of knockout 7 (178) 7 (178) 7 (178) 7 (178)
(E) Back of storage to
REFRIGERATED STORAGE
CONNECTION BOX
, center of knockout 11 (279) 11 (279) 11 (279) 11 (279)
Waste Outlet
(C) RH End of case to the center of waste outlet 24
1
/4 (616) 24 1/4 (616) 24 1/4 (616) 24 1/4 (616)
(D) LH End of case to the center of waste outlet 23 7/
8 (606) 47
7
/
8 (1216) 72
3
/
4 (1848) 72
1
/
8 (1832)
Back O/S of case to center of waste outlet 28
1
/8 (714) 28 1/8 (714) 28 1/8 (714) 28 1/8 (714)
Water Seal
Edge of water seal to center of waste outlet 4 (102) 4 (102) 4 (102) 4 (102) Outside diameter of the drip pipe 1 1/2 (38) 1 1/2 (38) 1 1/2 (38) 1 1/2 (38)
NOTE: Water seal outlet must clear front skid rail; water seal rotation in forward direction only due to low base.
Refrigeration Outlet
Back of case to center of refrigeration outlet 31 1/4 (794) 31 1/4 (794) 31 1/4 (794) 31 1/4 (794) RH end of case to center of refrigeration outlet 8 3/8 (213) 8 3/8 (213) 8 3/8 (213) 8 3/8 (213)
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/2 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
7
/8
Page 5
REFRIGERATION DATA
Note: This data is based on store temperature and
humidity that does not exceed 75 (°F) and 55% R.H.
E2SP
Meat Deli
Discharge Air (°F) 25 28
Evaporator (°F) 18 21
Unit Sizing (°F) 16 19
Btu/hr/ft
E2SP
Parallel 900 890
Conventional 1000 980
with refrigerated rear storage, add 300 Btu/hr/ft
Optional energy efficient motors reduce the
refrigeration load by 21 Btu/hr/ft.
DEFROST DATA
E2SP
Frequency (hr) 6
Defrost Water 8 lb/ft/day
(± 15% based on case configuration and product
loading).
OFFTIME E2SP
Temp Term (°F) 48
Failsafe (minutes) 40
ELECTRIC OR GAS Not Recommended
Standard Defrost Thermostat
Close on rise: close 48°F – open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control CI/CO**
E2SP Meat Deli
Temp (°F) 11 / 6 14 / 4
Indoor Unit Only, Pressure Defrost
Termination (Temp °F)
** 48°F
**Use a Temperature Pressure Chart to determine
PSIG conversions.
Estimated Charge (lb)*** E2SP
4 ft 0.9
6 ft 1.8
8 ft 1.9
12 ft 2.9
***This is an average for all refrigerant types actual
refrigerant charge may vary by approximately half a
pound.
5 of 10
P/N 0453525_C
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
C
O
I
L
Refrigeration Outlet
FAN
COIL
Electrical Connection Cavity & Fan
w/Refrigerated
Storage
w/ Non refrigerated
Storage
12
(305)
22
(559)
40 1/4
(1022)
35
(889)
9 3/4 (248)
12
(305)
19 1/8
(486)
31
(787)
E2SP
31 1/4
(794)
28 1/8
(714)
20
(508)
Standard Curved Sneeze Guard
53 3/4
(1365)
47
(1194)
59
(1499)
4 3/4 (121)
9 1/4
(235)
36
(914)
16
(406)
12
(305)
Impact
Elite
E2SP
Meat, Delicatessen
Precut & Packaged Produce
Elite Specialty Merchandiser Multi-deck, Prep Top, 2 Display Levels Optional Rear Storage, Refrigerated or Non refrigerated
Dimensions shown as in. & (mm).
See Page 9 for shelf arrangement.
Shown with curved sneeze guard and optional refrigerated and non-refrigerated rear storage.
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.
Page 6
6 of 10 E2SP Technical Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Impact
Elite
E2SP
Meat, Delicatessen Precut & Packaged Produce
Electrical Data
4 ft 6 ft 8 ft 12 ft
Number of Fans — 12W 1223
Number of Fans — 12W (Export) 1223
(Export: 230V 50 hz shown)
Amperes Watts
Merchandiser 4 ft 6 ft 8 ft 12 ft 4 ft 6 ft 8 ft 12 ft
Fans
Standard (120V 60Hz) 0.70 1.30 1.30 1.95 50 100 100 150
Energy Efficient (120V 60 Hz) 0.30 0.60 0.60 0.90 18 36 36 54
Export (230V 50Hz) 0.38 0.76 0.76 1.14 57 114 114 171
Optional Rear Refrigerated Storage 0.8 1.6 1.6 3.2 96 192 192 384
Constant-on Cavity Ambient Air Fan 0.25 0.25 0.25 0.25 23 23 23 23
(Standard on Optional Refrigerated Rear Storage)
Cycling Anti-sweat Heaters NA
Minimum Circuit Ampacity
With Standard Fans (120V 60Hz) 0.85 1.50 1.50 2.15
With Rear Refrigerated Storage
(standard fans) 1.96 3.46 3.46 5.56
With Energy Efficient Fans (120V 60 Hz) 0.50 0.80 0.80 1.10
With Export Fans (230V 50Hz) 0.58 0.96 0.96 1.34
Maximum Over Current Protection 20 20 20 20
Export (230V 50Hz) 15 15 15 15
Electric Defrost Heaters (208V 1Ph) NA
Standard Lighting
1 Row Canopy 0.51 0.51 0.51 0.76 62 62 62 92
Optional Lighting
1 Row Rail Lights 0.51 0.51 0.51 0.76 62 62 62 92
1 Row Ledge Lights 0.51 0.51 0.51 0.76 62 62 62 92
Optional Shelf Lighting
1 Row of Shelves 0.51 0.51 0.51 0.76 62 62 62 92
2 Rows of Shelves 0.51 1.01 1.01 1.52 62 122 122 185
Page 7
7 of 10P/N 0453525_C
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
= 120V POWER = 120V NEUTRAL
Defrost
Termination
Thermostat
Refrigeration
Thermostat
Dark Blue
5
To Condensing Unit
}
Light Blue
4
1, 2 or 3 Fans
120V NEUTRAL
B
ROWN BAND
120V POWER
Fans
1
B
ROWN BAND
Optional Refrigerated Rear Storage, 1 or 2 Fans
120V NEUTRAL
B
ROWN BAND
120V POWER
Fans
2
B
ROWN BAND
4 ft case has 1 Fan 6 ft case has 1 Fan 8 ft case has 2 Fans 12 ft case has 2 Fans
4 ft case has 1 Fan 6 ft case has 2 Fans 8 ft case has 2 Fans 12 ft case has 3 Fans
Cavity Fan, Ambient
120V NEUTRAL
B
ROWN BAND
120V POWER
Fan
3
B
ROWN BAND
4 ft case has 1 Fan 6 ft case has 1 Fan 8 ft case has 1 Fan 12 ft case has 1 Fan
Fan Wiring
Offtime Defrost
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Page 8
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
8 of 10 E2SP Data Sheet
R = Red Y = Yellow G = Green BL = Blue B = Black W = White
= 120V P
OWER = 120V NEUTRAL = Field GROUND
= Case GROUND
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
Connector
6
Connector
G
7
7
7
Connector
Connector
Connector
Connector
Connector
Optional Shelf Harness and Light Circuits for One Row of Shelves
120 V
Power
B
W
G
B
BL
BL
BL
G
G
R
R
BL
BL G
W
BL
Shelf Harness
Shelf Light Circuits
BL
G
W
R
G
G
R
R
R
G
G
G
R
BL
BL
Connector
Connector
B
4 ft
6 ft & 8 ft 12 ft
RR
BL
BL
Shelf Lighting
Page 9
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
9 of 10P/N 0453525B
Optional Lighting: 1 Row Ledge or 1 Row Rail
Light Circuits
Standard Lighting 1 Row Canopy
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
= 120V POWER = 120V NEUTRAL
R = Red Y = Yellow G = Green BL = Blue B = Black W = White
C
IRCLED NUMBERS = PARTS LIST ITEM NUMBERS
120V NEUTRAL
ORANGE OR TAN BAND
W
Light
Switch
120V POWER
ORANGE OR TAN BAND
BL
R
R
BL
BL
4
120V NEUTRAL
ORANGE OR TAN BAND
W
Light
Switch
120V POWER
ORANGE OR TAN BAND
B
BL
R
BL
BL
4
55
R
5
R
5
5
5
4 ft case has 1 Lamp 6 ft case has 2 Lamps 8 ft case has 2 Lamps 12 ft case has 3 Lamps
B
R
4 ft case has 1 Lamp 6 ft case has 2 Lamps 8 ft case has 2 Lamps 12 ft case has 3 Lamps
Page 10
10 of 10
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
SHELF CONFIGURATION
This merchandiser is designed for two shelves.
This illustration shows recommended shelf depth and shelf angle for the two locations.
It is critical to case performance that no product, shelf or stop extend beyond the load limit, as shown in this illustration. This configuration supports the air curtain and provides optimal case performance.
Check with Hussmann engineering before using a different configuration.
Load Limit
12 in.
10°
Recommended
Angle
Shelf
Size
18 in.
Impact
Elite
E2SP
Meat, Delicatessen Precut & Packaged Produce
10 of 10 E2SP Data Sheet