Hussmann E2 Specifications

B
D
D
E
C
E
A
P/N0453526B
E2
Technical Data Sheet
P/N 0453526_B
NSF
Certified
November 2009
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
Note: Rev. B adds Aftermarket part numbers on page 1; Btu note on page 3; other changes are underlined.
©2009 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
Item Part # Description Wiring Item #
FANASSEMBLIES AND
A. 7W Standard Fan Assembly (1)
0058698 Fan Motor, Evaporator
(MO.44101020)
0142780 Fan Blade (FB.0142780)
embossing toward motor
A. 7W Energy Efficient Fan Assembly (1)
0477654 Fan Motor, Evaporator
(MO.4410545)
0142780 Fan Blade (FB.0142780)
embossing toward motor
A. 7W Export Fan Assembly (1)
0436516 Fan Motor, Evaporator
(MO.4410106)
0142780 Fan Blade (FB.0142780)
embossing toward motor
Item Part # Description Wiring Item #
T
HERMOSTATS
B. 0411744 Standard Non-adjustable (2)
Defrost Thermostat (CT.0411744)
C. 0353949 Optional Adjustable (3)
Refrigeration Thermostat (CT.4481087)
L
AMPS AND BALLASTS
D. Ballast, Electronic (3)
0466234 2 lamps (BA.4480823) 0466235 3 lamps (BA.4480901) 0466236 4 lamps (BA.4481095)
E. Fluorescent Lamp (5)
Replace with like fixtures
4 ft 6 ft 8 ft 12 ft
General
(A) Case Length (without ends or partitions) 48 1/8 (1222) 72 1/8 (1832) 96 1/4 (2445) 144 3/8 (3667)
NOTE: Each end and insulated partition adds 1 inch to lineup.
Maximum O/S dimension back to front (with bumper) 46 1/
2 (1181) 46
1
/
2 (1181) 46
1
/
2 (1181) 46
1
/
2 (1181)
Back of case to front of front panel 34
1
/2 (876) 34 1/2 (876) 34 1/2 (876) 34 1/2 (876) Back of case to O/S edge of front skid rail 29 3/8 (746) 29 3/8 (746) 29 3/8 (746) 29 3/8 (746) Width of skid rail 4 1/
2 (114) 4
1
/
2 (114) 4
1
/
2 (114) 4
1
/
2 (114)
RH end of case to outside edge of external support 1
3
/
8 (34) 1
3
/
8 (34) 1
3
/
8 (34) 1
3
/
8 (34)
Distance between edges of
external support and center support NA 28
1
/
2 (724) 40
1
/
2 (1029) 40
1
/
2 (1029)
Distance between edges of center supports NA NA NA 44 (1118) Stub-up area between front skid rail and front panel 5
3
/4 (146) 5 3/4 (146) 5 3/4 (146) 5 3/4 (146)
Electrical Service (Electrical Field Wiring connection point)
(B) Length of electrical raceway 18 3/8 (467) 18 3/8 (467) 37 (940) 37 (940) (C) RH End of case to center of farthest knockout 36 5/8 (930) 60 3/4 (1543) 84 3/4 (2153) 132 3/4 (3372)
Back of case to center of end knockout 29 5/8 (752) 29 5/8 (752) 29 5/8 (752) 29 5/8 (752)
(D) RH End of case to RH end of raceway 27 5/8 (702) 51 5/8 (1311) 57 1/4 (1454) 105 1/8 (2670) (E) LH End of case to LH end of raceway 2 1/
8 (54) 2
1
/
8 (54) 2 (51) 2
1
/
4 (57)
Waste Outlet
(F) RH End of case to the center of waste outlet 24
1
/
4 (616) 24
1
/
4 (616) 24
1
/
2 (622) 72
1
/
4 (1834)
LH End of case to the center of waste outlet 23
7
/8 (606) 47 7/8 (1216) 71 3/4 (1822) 72 1/8 (1832) Back O/S of case to center of waste outlet 27 5/8 (702) 27 5/8 (702) 27 5/8 (702) 27 5/8 (702)
Water Seal
Edge of water seal to center of waste outlet 4 (102) 4 (102) 4 (102) 4 (102) Outside diameter of the drip pipe 1 1/
2 (38) 1
1
/
2 (38) 1
1
/
2 (38) 1
1
/
2 (38)
NOTE: Water seal outlet must clear front skid rail; water seal rotation in forward direction only due to low base.
Refrigeration Outlet
Back of case to center of refrigeration outlet 30
3
/4 (781) 30 3/4 (781) 30 3/4 (781) 30 3/4 (781) RH end of case to center of refrigeration outlet 8 3/
8 (213) 8
3
/
8 (213) 8
3
/
8 (213) 8
3
/
8 (213)
2 of 7 E2 Technical Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Engineering
Plan Views
Dimensions shown as inches and (mm).
09-2005
34 1/2
(876)
8 3/8 (213)
Electrical Service
29 5/8
(752)
Waste Outlet
Front
C
L
A
C
D
B
F
E
27 5/8
(702)
30 3/4
(781)
46 1/2
(1181)
Water Seal
E2
Delicatessen
Precut & Packaged
Produce
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/2 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
7
/8
REFRIGERATION DATA
Note: This data is based on store temperature
and humidity that does not exceed 75 (°F) and 55% R.H.
E2
M
EAT
DELI
Discharge Air (°F) 25 27
Evaporator (°F) 18 21
Unit Sizing (°F) 16 19
Btu/hr/ft
Parallel 945 920
Conventional 1030 1000
Optional energy efficient motors reduce the
refrigeration load by 21 Btu/hr/ft.
DEFROST DATA
Frequency (hr) 6 Defrost Water 8 lb/ft/day
(± 15% based on case configuration and
product loading).
O
FFTIME
E2 Temp Term (°F) 48 Failsafe (minutes) 40
E
LECTRIC OR G
AS
Not Recommended
Standard Defrost Thermostat
Close on rise: close 48°F – open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control CI/CO*
E2 Meat Deli
Temp (°F) 11 / 6 14 / 4
Indoor Unit Only, Pressure Defrost Termination (Temp °F)
* 48°F
*Use a Temperature Pressure Chart to determine PSIG conversions.
Estimated Charge (lb)** E2
4 ft 0.9 6 ft 1.8 8 ft 1.9 12 ft 2.9
**This is an average for all refrigerant types actual refrigerant charge may vary by approximately half a pound.
3 of 7
P/N 0453526_B
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Impact
Elite
E2
Delicatessen
Precut & Packaged Produce
Elite Specialty Merchandiser Multi-deck, 2 Display Levels
Dimensions shown as in. & (mm).
7 1/2 (191)
48 3/4
(1238)
FAN
C O
I
L
31 (787)
23 3/4
(603)
17 1/8
(435)
12
(305)
22
(559)
34 1/2
(876)
46 1/2
(1181)
12
(305)
27 5/8
(702)
30 3/4
(781)
E2
4 1/4
(108)
12 (305)
18 (457)
Refrigeration Outlet
See Page 7 for shelf arrangement.
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.