![](/html/bd/bdc1/bdc18d5fe8deb09058a6b154b528321d5fa6442d8fd191a5942049bb885b33b0/bg1.png)
B
(Optional
Lights)
A
E
D
C
T'Stat Bulb
Location
E1S
Technical Data Sheet
P/N 0453531_C
NSF
®
Certified
April 2010
Item Part # Description Wiring Item #
FAN ASSEMBLIES AND THERMOSTATS
A. 4W Standard Fan Assembly (1)
0392457 Fan Motor, Evaporator
(MO.4410101)
0409513 Fan Blade, (FB.0409513)
embossing toward motor
B. 0411744 Standard Non-adjustable (2)
Defrost Thermostat (CT.0411744)
C. Optional Adjustable Refrigeration Thermostat (3)
Item Part # Description Wiring Item #
H
EATERS
D. 0496496 Heater, Anti-Sweat (4)
(HE.4850738)
L
AMPS AND BALLASTS
E. 0355716 Ballast, Electronic
2 lamps (BA.0355716) (5)
Fluorescent Lamp (6)
Replace with like fixtures
Note: Revision C adds page 5 and updates pages 1, 2 & 4. Changes are underlined, circled or marked with a vertical line in
the margin.
©2010 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
P/N0453531C
We reserve the right to change or revise specifications
and product design in connection with any feature of
our products. Such changes do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for equipment previously sold or shipped.
![](/html/bd/bdc1/bdc18d5fe8deb09058a6b154b528321d5fa6442d8fd191a5942049bb885b33b0/bg2.png)
4 ft 6 ft 8 ft 12 ft
General
(A) Case Length (without ends or partitions) 48 1/
4 (1226) 72
3
/
8 (1838) 96
3
/
8 (2448) 144
1
/
2 (3670)
NOTE: Each end or insulated partition adds 1 inch to lineup.
Maximum O/S dimension back to front (with bumper) 46 1/8 (1172) 46 1/8 (1172) 46 1/8 (1172) 46 1/8 (1172)
Back of case to front of front panel 34 1/8 (867) 34 1/8 (867) 34 1/8 (867) 34 1/8 (867)
RH end of case to outside edge of external support 1 3/
8 (35) 1
3
/
8 (35) 1
3
/
8 (35) 1
3
/
8 (35)
Distance between edges of
external support and center support NA 28
1
/2 (724) 40 1/2 (1029) 40 1/2 (1029)
Distance between edges of center supports NA NA NA 43 7/
8 (1114)
Distance between edges of external supports 37 (940) NA NA NA
Electrical Service (Electrical Field Wiring connection point)
(C) Length of electrical wireway 34
1
/2 (876) 26 (660) 38 (965) 38 (965)
RH End of case to center of farthest knockout 12 1/4 (311) 12 1/4 (311) 12 1/4 (311) 12 1/4 (311)
Back of case to center of end knockout 5 1/4 (133) 5 1/4 (133) 5 1/4 (133) 5 1/4 (133)
(B) RH End of case to RH end of raceway 6 7/8 (175) 6 7/8 (175) 6 7/8 (175) 6 7/8 (175)
Waste Outlet
(D) RH End of case to the center of waste outlet 24 1/8 (613) 24 1/8 (613) 24 1/8 (613) 72 1/4 (1835)
LH End of case to the center of waste outlet 24 1/8 (613) 48 1/4 (1226) 72 1/4 (1835) 72 1/4 (1835)
Back O/S of case to center of waste outlet 27 1/8 (689) 27 1/8 (689) 27 1/8 (689) 27 1/8 (689)
Water Seal
Edge of water seal to center of waste outlet 4 (102) 4 (102) 4 (102) 4 (102)
Schedule 40 diameter of the drip pipe 1 1/2 (38) 1 1/2 (38) 1 1/2 (38) 1 1/2 (38)
(Field installed water seal outlets, tees, and connectors
are shipped with the merchandiser.)
Refrigeration Outlet
Back of case to center of refrigeration outlet 30 1/4 (768) 30 1/4 (768) 30 1/4 (768) 30 1/4 (768)
(E) RH end of case to center of refrigeration outlet 9 3/8 (238) 9 3/8 (238) 9 3/8 (238) 9 3/8 (238)
2 of 7 E1S Technical Data Sheet
U.S. & Canada 1-800-922-1919 • Mexico 1-800-522-1900
Engineering
Plan Views
Dimensions shown as inches and (mm).
04-2010
E1S
Delicatessen
Precut & Packaged
Produce
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/2
Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
7
/8
Legs
Waste Outlet
27 1/8
(689)
Front
Wate r
Seal
D
C
5 1/4 (133)
Wireway
Refrigeration
Outlet
B
30 1/4
(768)
E
34 1/8
(867)
46 1/8
(1172)
![](/html/bd/bdc1/bdc18d5fe8deb09058a6b154b528321d5fa6442d8fd191a5942049bb885b33b0/bg3.png)
3 of 7
P/N 0453531_C
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Impact
Elite
E1S
Delicatessen
Precut & Packaged Produce
Elite specialty self-serve merchandiser, straight front glass, 1 display level
Dimensions shown as inches and (mm).
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF
(National Sanitation Foundation) Standard #7 requirements for
construction, materials & cleanability.
REFRIGERATION DATA
Note: This data is based on store temperature
and humidity that does not exceed 75 (°F)
and 55% R.H.
E1S
Discharge Air (°F) 27
Evaporator (°F) 20
Unit Sizing (°F) 18
Btu/hr/ft E1S
Parallel 490
Conventional 525
DEFROST DATA
E1S
Frequency (hr) 12
Defrost Water (lb/ft/day)8
(± 15% based on case configuration and
product loading).
OFFTIME E1S
Temp Term (°F) 43
Failsafe (minutes) 90
ELECTRIC OR GAS Not Recommended
Standard Defrost Thermostat
Close on rise: close 48°F – open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control
CI/CO
* E1S
Temp (°F) 13 / 3
Indoor Unit Only, Pressure Defrost
Termination Not Recommended
*Use a Temperature Pressure Chart to
determine PSIG conversions.
Estimated Charge ** E1
4 ft 0.8 lb 13 oz 0.4 kg
6 ft 1.2 lb 19 oz 0.5 kg
8 ft 1.5 lb 24 oz 0.7 kg
12 ft 2.0 lb 32 oz 1.9 kg
**This is an average for all refrigerant types
actual refrigerant charge may vary by
approximately half a pound.
32
(813)
E1S
22
(559)
12
(305)
8 7/8
(225)
7
(178)
33 1/8
(841)
Refrigeration
Outlet
FAN
COIL
27 1/8
(689)
30 1/4
(768)
34 1/8
(867)
46 1/8
(1172)
37 3/8
(949)
4 3/4
(121)