Hussmann DD5X-LRE Specifications

G
C
B
A
C
E
D
F
D
Item Part # Description Wiring Item #
FAN ASSEMBLIES 8 Ft & 12 Ft
0047000 Fan Motor, Evaporator
(MO.4410103)
0463643 Fan Blade (FB.4780648)
12W Energy Efficient Fan Assembly (1) 0477655 Fan Motor, Evaporator
(MO.4410546)
0463643 Fan Blade (FB.4780648)
T
HERMOSTATS
B. Optional Adjustable Refrigeration Thermostat (2)
Item Part # Description Wiring Item #
L
AMPS AND BALLASTS
C. Ballast, Electronic (3)
0480130 2 lamps (BA.4481676) 0480131 3 lamps (BA.4481654) 0480132 4 lamps (BA.4481677)
D. Fluorescent Lamp (4)
Replace with like fixtures
LED F
IXTURES AND POWER SUPPLY
E. 0501213 Power Supply (EP.4481861) (5)
F. LED Canopy Fixture (6)
Replace with like fixtures — See Page 5.
G. LED Shelf Fixture (7)
Replace with like fixtures — See Page 5.
DD5X-LRE
Technical Data Sheet
P/N 0516995_A
NSF
®
Certified
August 2010
©2010 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
Note: Revision A is original issue
P/N_0516995-A
DD5X-LRE Technical Data Sheet
NOTE: Case-to-Case Electrical Connections are made IN FRONT OF SPLASHGUARD.
Splashguard
Waste Outlet
FRONT
3 3/8
(85)
12 1/8 (307)
Electrical Field Connection
5 1/2 (140)
13/8 (35)
4 1/4 (108)
8 (203)
Waste Outlet
B
Refrigeration
Outlet
Electrical
Stub Up Area
6 x 6
(152 x 152)
Wireway
D
A
C
26 1/2
(673)
20
(508)
40 5/8
(1032)
44
(1118)
40 5/8
(1032)
34 7/8
(885)
36 7/8
(937)
29 3/8
(745)
45 1/2
(1155)
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
2 of 11
General 8 ft 12 ft
(A) Case Length (without ends or partitions) 96 3/8 (2448) 144 1/2 (3670)
(Each end and insulated partition adds 1 1/2 in. (38 mm) to case line up.)
Maximum O/S dimension of case 45 1/2 (1155) 45 1/2 (1155)
(back to front, including bumper)
Back of case to front of splashguard 36 7/8
(937) 36
7
/8
(937)
Back of case to O/S edge of front skid rail 29
1
/2 (749) 29 1/2 (749) Width of skid rail 2 3/8 (61) 2 3/8 (61) RH end of case to outside edge of external support 5 1/2
(140) 5
1
/2
(140)
Distance between edges of external support
and center support 40
5
/8 (1032) 40 5/8 (1032) Distance between edges of center supports NA 44 (1118) Distance between front skid rail and splashguard 6 (152) 6 (152)
Electrical Service (Electrical Field Wiring connection point)
(B) RH End of case to center of stub up area 84 1/4 (2140) 132 3/8 (3363)
Back of case to center of stub up area 20 (508) 20 (508) Length of electrical wireway 26 1/2 (673) 26 1/2 (673)
(C) RH End of case to LH end of wireway 90 1/8 (2289) 138 1/4 (3511)
Waste Outlets (One each end)
(D) End of case to the center of farthest waste outlet 84 1/4 (2140) 132 3/8 (3363)
End of case to the center of nearest waste outlet 12 1/8 (307) 12 1/8 (307) Back O/S of case to center of waste outlets 34 7/8 (885) 34 7/8 (885) Outside diameter of the drip pipe 1 1/4 (32) 1 1/4 (32)
Refrigeration Outlet
Back of case to center of refrigeration outlet 29 3/8 (745) 29 3/8 (745) RH end of case to center of refrigeration outlet 8 (203) 8 (203)
Engineering
Plan Views
Dimensions shown as in. and (mm).
Rear Load Dairy
& Delicatessen
08-2010
DD5X-LRE
12 ft plan view is shown.
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/4 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
7
/8
Wireway
REFRIGERATION DATA
Note: This data is based on store temperature and
humidity that does not exceed 75°F and 55% R.H.
DD5X-LRE UNLIT LIT PEG*
Discharge Air °F 39 37 37
Evaporator °F 34 32 32
Unit Sizing °F 32 30 30
Btu/hr/ft
— Unlit Shelves
‡‡
DD5X-LRE Parallel Conventional
U
NLIT
410 420
P
EG* 440 450
* Hussmann Peg Shelves (Deli only).
Optional energy efficient motors reduce the
refrigeration load by 27 Btu/hr/ft. ‡‡
Add 10 Btu/hr/ft per shelf row for LED fixtures.
Add 20 Btu/hr/ft per shelf row for fluorescent lamps.
DEFROST DATA
Frequency Hr 24
Defrost Water (lb/ft/day) 1.0
(± 15% based on case configuration and product
loading).
OFFTIME DD5X-LRE
Time (
Minutes) 25
ELECTRIC OR GAS Not Recommended
CONVENTIONAL CONTROLS
Low Pressure Backup Control
CI/CO** DD5X-LRE
25°F / 15°F
Indoor Unit Only,
Pressure Defrost Termination** 48°F
**Use a Temperature Pressure Chart to determine
PSIG conversions.
Estimated Charge *** DD5X-LRE
8 ft 2.7 lb 43 oz 1.2 kg
12 ft 3.9 lb 62 oz 1.8 kg
***This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound.
3 of 11
P/N 0516995_A
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
3 (76)
34 7/8 (885)
3 3/8 (85)
43 7/8 (1113)
36 7/8 (937)
29 3/8 (745)
22 1/2
(572)
30 1/8
(766)
61
(1549)
FAN
DD5X-LRE
17 3/8
(442)
81 7/8
(2078)
7 1/4 (183)
19 3/4
(503)
3 3/4
(95)
COIL
Electrical
Case to Case
Connections
45 1/2
(1155)
6
(152)
Refrigeration Outlet
3 1/8 (79)
45 1/2 (1147)
53 1/2
(1359)
Impact
Excel
DD5X-LRE
Dairy & Delicatessen
Dimensions shown as in. and (mm).
Multi-deck, 5 Display Levels with Sliding Rear Door, Low Front
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.
4 of 11 DD5X-LRE Technical Data Sheet
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
Impact
Excel
DD5X-LRE
Dairy & Delicatessen
Electrical Data
8 ft 12 ft Number of Fans – 12W 2 3 Number of Fans – 7W
Amperes Watts
8 ft 12 ft 8 ft 12 ft Evaporator Fans
120V 60Hz Standard 1.30 1.95 100 150 120V 50Hz Standard 1.50 2.25 114 171 230V 60Hz Export 0.66 0.99 100 150 230V 50Hz Export 0.76 1.14 114 171 120V 60Hz Energy Efficient 0.60 0.90 36 54 230V 60Hz Energy Efficient 0.30 0.45 36 54
Minimum Circuit Ampacity
120V 60Hz Standard 1.50 2.15 120V 50Hz Standard 1.70 2.45 230V 60Hz Export 0.86 1.19 230V 50Hz Export 0.96 1.34 120V 60Hz Energy Efficient 0.80 1.10 230V 60Hz Energy Efficient 0.50 0.65
Maximum Over Current Protection 120V 20 20
Maximum Over Current Protection 230V 15 15
Standard Lighting (T-8 fluorescent)
1 Row Canopy 0.51 0.77 59 85
Optional Lighting (T-8 fluorescent)
Additional 1 Row Canopy 0.51 0.77 59 85 Additional 2 Row Canopy 1.02 1.54 118 170 Additional 3 Row Canopy 1.53 2.31 177 255 1 Row of Shelves 0.51 0.77 59 85 4 Rows of Shelves 2.04 3.08 236 340 5 Rows of Shelves 2.55 3.85 295 425 6 Rows of Shelves 3.06 4.62 354 510
Optional LED Canopy Lighting EcoShine CRI — 120VAC, 50/60Hz
2 Row Canopy 0.55 0.82 66 98 1 Rows of Shelves 0.20 0.29 24 35 4 Rows of Shelves 0.78 1.17 93 140 5 Rows of Shelves 0.97 1.45 116 174 6 Rows of Shelves 1.17 1.74 140 209
EcoShine High CRI — 120VAC, 50/60Hz 2 Row Canopy 0.62 0.93 74 112 1 Rows of Shelves 0.23 0.35 28 42 4 Rows of Shelves 0.93 1.40 112 168 5 Rows of Shelves 1.17 1.75 140 210 6 Rows of Shelves 1.40 2.10 168 252
120V Lighting Circuit Total = Standard Lighting + Total Optional Lighting + Optional Shelf Lighting 230V Lighting Circuit Total = Multiply 120V Lighting Circuit Total by 0.52