Hussmann D6X-URLE Specifications

Page 1
Item Part # Description Wiring Item #
FAN ASSEMBLIES 8 Ft & 12 Ft
A. 13W Standard Fan Assembly — Discharge (1)
0378349 Fan Motor, Discharge
(MO.4410104)
0463643 Fan Blade (FB.4780648) 13W Energy Efficient Fan Assembly — Discharge 0477656 Fan Motor, Discharge
(MO.4410547)
0463643 Fan Blade (FB.4780648)
A. 13W Standard Fan Assembly — Discharge (1)
0378349 Fan Motor, Discharge
(MO.4410104)
0124150 Fan Blade (FB.0124150) 13W Energy Efficient Fan Assembly — Discharge 0477656 Fan Motor, Discharge
(MO.4410547)
0124150 Fan Blade (FB.0124150)
8 Ft & 12 Ft
B. 12W Standard Fan Assembly — Return (2)
0047000 Fan Motor, Return
(MO.4410103)
0315470 Fan Blade (FB.0315470) 12W Energy Efficient Fan Assembly — Return 0477655 Fan Motor, Return
(MO.4410546)
0315470 Fan Blade (FB.0315470)
Item Part # Description Wiring Item #
B. 7W Standard Fan Assembly — Return (2)
0058698 Fan Motor, Return
(MO.4410102)
0124150 Fan Blade (FB.0124150) 7W Energy Efficient Fan Assembly — Return 0477654 Fan Motor, Return
(MO.4410545)
0124150 Fan Blade (FB.0124150)
THERMOSTATS
C. Optional Adjustable Refrigeration Thermostat (3)
L
AMPS AND BALLASTS
D. Ballast, Electronic (4)
0480130 2 lamps (BA.4481676) 0480131 3 lamps (BA.4481654) 0480132 4 lamps (BA.4481677)
E. Fluorescent Lamp (5)
Replace with like fixtures
LED F
IXTURES AND POWER SUPPLY
F. 0501213 Power Supply (EP.4481861) (6)
G. LED Canopy Fixture (7)
Replace with like fixtures — See Page 5.
B
F
C
A
G
D
E
P/N_0498329_F
D6X-URLE
Technical Data Sheet
P/N 0498329_F
NSF
®
Certified
March 2010
©2010 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
ONE FLOOR DRAIN IS
REQUIRED FOR EACH CASE.
IMPORTANT
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
Note: Revision E adds Btu note (page 3), EcoShine LED (page 4) and parts (page 5), and revises canopy wiring diagram (page 6). Other changes marked by bar, underline or circle.
Page 2
6 ft 8 ft 12 ft
General
(A) Case Length (without ends or partitions) 72 3/
8 (1838) 96
3
/
8 (2448) 144
1
/
2 (3670)
(Each end and insulated partition adds 1 1/2 in. (38 mm) to case line up.)
Maximum O/S dimension of case back to front 51 5/8 (1311) 51 5/8 (1311) 51 5/8 (1311)
(front of canopy through cooler wall not including electrical box)
Cooler wall to front of splashguard 43 3/4 (1111) 43 3/4 (1111) 43 3/4 (1111) Cooler wall to O/S edge of front rails 40 3/4 (1035) 40 3/4 (1035) 40 3/4 (1035) Distance between edges of external rails and center rails 41 1/2 (1054) 41 1/2 (1054) 41 1/2 (1054) Distance between edges of center rails NA NA 43 7/8 (1114) Distance between front rails and splashguard 7 3/
4
(197) 7
3
/
4
(197) 7
3
/
4
(197)
Electrical Service (Electrical Field Wiring connection point located on top of case)
(B) RH End of case to center of 4 x 4 x 2 Electrical Box 2 (51) 2 (51) 2 (51)
Back of case (cooler wall) to center of 4 x 4 x 2 Electrical Box 2
1
/4 (57) 2 1/4 (57) 2 1/4 (57)
Waste Outlets (One each end)
(C) RH End of case to the center of LH waste outlet 60 1/4 (1530) 84 1/4 (2140) 132 3/8 (3363)
RH End of case to the center of RH waste outlet 12 1/8 (308) 12 1/8 (308) 12 1/8 (308) Cooler wall to center of waste outlets 42 (1067) 42 (1067) 42 (1067) Schedule 40 PVC drip pipe 1 1/4 (32) 1 1/4 (32) 1 1/4 (32)
Refrigeration Outlet
Cooler wall to center of refrigeration outlet 4 1/4 (108) 4 1/4 (108) 4 1/4 (108)
(D) RH end of case to center of refrigeration outlet 69 1/4 (1759) 93 1/4 (2369) 141 3/8 (3591)
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
D6X-URLE Technical Data Sheet 2 of 10
Engineering
Plan Views
B
Front
C
L
Upper Electrical
Box
Upper Refrigeration Outlet
A
Cooler Wall
Canopy
Bumper
Waste Outlet
43
(1092)
C
12 1/8
(308)
Splashguard
Waste Outlet
D
Dimensions shown as in. & (mm).
Rear Load
Ultra Low Front Dairy
09-2007
Note: ALL FIELD WIRING CONNECTION POINTS ARE ABOVE THE CASE. Case to case connections are made in the electrical box at the top of the case.
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/4 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
7
/8
Page 3
REFRIGERATION DATA
Note: This data is based on store temperature and
humidity that does not exceed 75°F and 55% R.H.
D6X-URLE
Discharge Air (°F) 27
Evaporator (°F) 21
Unit Sizing (°F) 19
Important Note: Btu numbers are for the D6X-
URLE when installed to a cooler operating at a
36°F air temperature. The unit cooler coil must
be sized for an additional load of 1160
Btu/hr/ft of D6X-URLE case installed to the
cooler.
Btu/hr/ft
D6X-URLE
Parallel
1200
Conventional
1375
Optional energy efficient motors reduce the
refrigeration load by 70 Btu/hr/ft.
DEFROST DATA
D6X-URLE
Frequency (hr) 6
Defrost Water (lb/ft/day) 6
(± 15% based on case configuration and
product loading).
OFFTIME D6X-URLE
Time Terminated (minutes) 45
ELECTRIC OR GAS Not Recommended
Standard Defrost Thermostat — NA
CONVENTIONAL CONTROLS
Low Pressure Backup Control
D6X-URLE
CI/CO (Temp °F)* 14 / 4
Indoor Unit Only, Pressure Defrost
Termination (Temp °F)* NA
*Use a Temperature Pressure Chart to
determine PSIG conversions.
Estimated Charge ** D6X-URLE
6 ft 2.0 lb 32 oz 0.9 kg
8 ft 2.7 lb 43 oz 1.2 kg
12 ft 3.9 lb 62 oz 1.8 kg
**This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound.
P/N 0498329_F
Fan
Coil
Fan
40 7/8 (1038)
41 5/8 (1057)
45 3/8 (1153)
34 7/8 (886)
33 7/8 (860)
24 5/8 (626)
6 3/8
(162)
51 5/8 (1311)
84
(2134)
89 7/8
(2283)
4 1/8 (106)
7 1/4
(184)
11 1/2
(292)
92
(2337)
10 1/4
(260)
12 3/4
(324)
3 (76)
29 7/8 (758)
67 3/4
(1721)
2 1/8
(54)
C O O L E R
W
A L L
3 3/4
(95)
C O O L E R
W
A L L
70 3/8
(1788)
Dimensions shown as in. & (mm).
Ultra Low Front, Rear Load
3 of 10
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Impact
Excel
D6X-URLE
Dairy
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.
ALL FIELD WIRING CONNECTION POINTS ARE ABOVE THE CASE.
D6X-URLE
Page 4
Electrical Data
Number of Fans 6 ft 8 ft 12 ft
Discharge — 13W 4 4 6 Return — 12W 46 Return — 7W 4 ——
Amperes Watts
6 ft 8 ft 12 ft 6 ft 8 ft 12 ft
Discharge Fan
120V 60Hz Standard 3.08 3.08 4.62 244 244 366 120V 50Hz Standard 3.92 3.92 5.88 280 280 420 230V 60Hz Export 1.56 1.56 2.34 244 244 366 230V 50Hz Export 1.92 1.92 2.88 280 280 420 120V 60Hz Energy Efficient 1.20 1.20 1.80 80 80 120 230V 60Hz Energy Efficient 0.60 0.60 0.90 80 80 120
Return Fan
120V 60Hz Standard 2.00 2.60 3.90 156 200 300 120V 50Hz Standard 2.20 3.00 4.50 168 228 342 230V 60Hz Export 1.00 1.32 1.98 156 200 300 230V 50Hz Export 1.12 1.52 2.28 168 228 342 120V 60Hz Energy Efficient 0.76 1.20 1.80 56 72 108 230V 60Hz Energy Efficient 0.40 0.60 0.90 56 72 108
Minimum Circuit Ampacity
120V 60Hz Standard 5.28 5.88 8.72 120V 50Hz Standard 6.32 7.12 10.58 230V 60Hz Export 2.76 3.08 4.52 230V 50Hz Export 3.04 3.64 5.36 120V 60Hz Energy Efficient 2.16 2.60 3.80 230V 60Hz Energy Efficient 1.20 1.40 2.00
Maximum Over Current Protection 120V 20 20 20
Maximum Over Current Protection 230V 15 15 15
Standard Lighting (T-8 fluorescent)
1 Row Canopy 0.51 0.51 0.77 59 59 85
Optional Lighting (T-8 fluorescent)
Additional 1 Row Canopy 0.51 0.51 0.77 59 59 85 Additional 2 Row Canopy 1.02 1.02 1.54 118 118 170 1 Row Rail Light 0.51 0.51 0.77 59 59 85
EcoShine Multi-deck — Normal CRI—120VAC, 50/60Hz
2 Row Canopy (Front & Rear) 0.41 0.55 0.82 49 66 98
EcoShine Multi-deck — High CRI —120VAC, 50/60Hz
2 Row Canopy (Front & Rear) 0.47 0.63 0.93 56 75 112
Always*Bright Multi-deck —120VAC, 50/60Hz
2 Row Canopy 0.55 0.71 1.08 66 85 130
Lighted shelves are not available for rear-load models.
120V Lighting Circuit Total = Standard Lighting + Total Optional Lighting + Optional Shelf Lighting 230V Lighting Circuit Total = Multiply 120V Lighting Circuit Total by 0.52
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
D6X-URLE Technical Data Sheet 4 of 10
Impact
Excel
D6X-URLE
Dairy
Page 5
5 of 10P/N 0498329_F
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
ESTIMATED SHIPPING WEIGHT
4
Case Solid End
6 ft 8 ft 12 ft (each)
lb (kg) 900 (408) 1170 (531) 1750 (794) 90 (41)
4
Actual weights will vary according to optional kits included.
Product Data
Recommended Usable Cube
1
(Cu Ft/Ft) 10.47 ft3 /ft (0.97 m3 /m)
Total Display Area
2
(Sq Ft/Ft) 5.73 ft2/ft (1.75 m2 /m)
Shelf Area 3(Sq Ft/Ft) 9.86 ft2/ft (3.01 m2 /m)
1
Refrigerated Volume less shelving and other unusable space: Refrigerated Volume/Unit of Length, ft3/ft [m3/m]
2
Total Display Area, ft2[m2]/Unit of Length, ft [m]
3
Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann Product Reference Guide. The standard shelf complement for this model is (5) rows of 22-inch shelves.
Impact
Excel
D6X-URLE
Dairy
PARTS LIST (Continued from Page 1)
Note: Always*Bright lamps will be replaced with the latest generation of EcoShine lamps.
Item Part # Description
LED F
IXTURES AND POWER SUPPLY
F. 0501213 Power Supply (EP.4481861) (6)
G. EcoShine LED Canopy Fixture (7)
4441720 Front 48-inch 2900K HCRI 4441722 Front 48-inch 3500K HCRI 4441724 Front 48-inch 3500K 4441726 Front 48-inch 4100K 4441721 Rear 48-inch 2900K HCRI 4441723 Rear 48-inch 3500K HCRI 4441725 Rear 48-inch 3500K 4441727 Rear 48-inch 4100K
Item Part # Description
G.
(CONTINUED) EcoShine LED Canopy Fixture
4441712 Front 36-inch 2900K HCRI 4441714 Front 36-inch 3500K HCRI 4441716 Front 36-inch 3500K 4441718 Front 36-inch 4100K 4441713 Rear 36-inch 2900K HCRI 4441715 Rear 36-inch 3500K HCRI 4441717 Rear 36-inch 3500K 4441719 Rear 36-inch 4100K
Page 6
D6X-URLE Technical Data Sheet
6 of 10
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
5
5
4
4
5
6
5
5
Optional
Two Row
Canopy
Connector
BL
BL
W
G
R
BL
W
R
R
R
BL
BL
R
BL
R
R
R
BK
BK
Orange or Tan Band
5
4
55
Connector
W
BK
BL
BL
R
BL
R
R
R
BK
6 ft or 8 ft 12 ft
6 ft or 8 ft 12 ft
Ballast Plug for Optional Light Rail (if applied)
W
BK
Field Connections
Case
Ground
Bar
2
120V NEUTRAL
B
ROWN BAND
120V POWER
Fans
1
B
ROWN BAND
Refrigeration
Thermostat
To Condensing Unit
}
Light Blue
3
4 & 6 Discharge Air Fans
2
120V NEUTRAL
B
ROWN BAND
120V POWER
Fans
1
B
ROWN BAND
4 & 6 Return Air Fans
Fan Wiring Offtime Defrost
Light Circuits — Fluorescent Fixtures
R = Red Y = Yellow G = Green BL = Blue BK = Black W = White
= 120V P
OWER = 120V NEUTRAL = FIELD GROUND
= CASE GROUND
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
Page 7
7 of 10P/N 0498329_F
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
R = Red Y = Yellow G = Green BL = Blue BK = Black W = White
= 120V P
OWER = 120V NEUTRAL = FIELD GROUND
= CASE GROUND
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
7
7
7
7
7
7
7
7
7
7
6
6
6
Optional Canopy Lighting
LED Fixtures
Page 8
D6X-URLE Technical Data Sheet
8 of 10
Doors Fully Closed
NOTE: Consult Ultra-Low Front Installation manual for instructions
on connecting the merchandiser
to the cooler.
Rear View of 6 Foot Dairy Merchandiser
69 1/
2
22 3/
4
29 1/
2
80 7/
8
65 7/
8
Doors Fully Opened
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
Page 9
9 of 10P/N 0498329_F
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Doors Fully Closed
NOTE: Consult Ultra-Low Front Installation manual for instructions
on connecting the merchandiser
to the cooler.
Rear View of 8 Foot Dairy Merchandiser
69 1/
2
34 3/
4
41 1/
2
80 7/
8
89 7/
8
Doors Fully Opened
Page 10
D6X-URLE Technical Data Sheet
10 of 10
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
69
1
/
2
80
7
/
8
NOTE: Consult Ultra-Low Front Installation manual
for instructions on connecting the merchandiser
to the cooler.
Rear View of 12 Foot Dairy Merchandiser
41
1
/
2
Doors
Fully Closed
34
3
/
4
Doors
Fully Opened
138
41
1
/
2
Doors
Fully Closed