Hussmann D6NX-LEP Specifications

C
B
C
D
D
D
A
G
E
F
P/N_0463872_F
D6NX-LEP
Technical Data Sheet
NSF
®
Certified
March 2010
Item Part # Description Wiring Item #
FAN ASSEMBLIES 4 Ft, 8 Ft & 12 Ft
A. 12W Standard Fan Assembly (1)
0047000 Fan Motor, Evaporator
(MO.4410103)
0461805 Fan Blade (FB.4780446) 12W Energy Efficient Fan Assembly (1) 0477655 Fan Motor, Evaporator
(MO.4410546)
0461805 Fan Blade (FB.4780446)
T
HERMOSTATS
B. Optional Adjustable Refrigeration Thermostat (2)
Item Part # Description Wiring Item #
L
AMPS AND BALLASTS
C. Ballast, Electronic (3)
0480130 2 lamps (BA.4481676) 0480131 3 lamps (BA.4481654) 0480132 4 lamps (BA.4481677)
D. Fluorescent Lamp (4)
Replace with like fixtures
LED F
IXTURES AND POWER SUPPLY
E. 0501213 Power Supply (EP.4481861) (5)
F. LED Canopy Fixture (6)
Replace with like fixtures — See Page 5.
G. LED Shelf Fixture (7)
Replace with like fixtures — See Page 5.
©2010 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
Note: Rev. F adds Btu note (page 3), and EcoShine LED (page 4) and parts (page 5), and revises canopy wiring diagram (page 6). Other changes marked by underline or circle.
D6NX-LEP Technical Data Sheet
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
2 of 9
Wireway
26 3/4
(680)
25 1/4
(641)
37
(940)
A
41 1/2
(1054)
28 1/2
(724)
3 In.
(77 mm)
Required
Air Gap
Refrigeration
Outlet
Waste Outlet
Waste Outlet
FRONT
4 3/4 (120)
21 1/4
(540)
D
C
8 (203)
12 1/8 (307)
4 1/4 (108)
41 1/2
(1054)
43 7/8
(1114)
B
Splashguard
19
(483)
NOTE: Case-to-Case Electrical Connections are made IN FRONT OF SPLASHGUARD.
Electrical
Stub Up Area
6 x 6
(152x152)
Electrical Field Connection
26 1/2
(673)
4 3/4 (120)
4 1/2 (115)
Engineering
Plan Views
Dimensions shown as in. and (mm).
Narrow Dairy &
Delicatessen
10-2004
D6NX
4 ft 8 ft 12 ft
General
(A) Case Length (without ends or partitions) 48 3/8
(1229) 96
3
/8
(2448) 144
1
/2
(3670)
(Each end and insulated partition adds 1 1/2 in. (38 mm) to case line up.)
Maximum O/S dimension of case back to front
(includes bumper) 37 (940) 37 (940) 37 (940)
Back of case to front of splashguard 28 1/2 (724) 28 1/2 (724) 28 1/2 (724) Back of case to O/S edge of front leg 25 1/4 (641) 25 1/4 (641) 25 1/4 (641) Distance between edges of external legs and center legs NA 41 1/2 (1054) 41 1/2 (1054) Distance between edges of center legs NA NA 43 7/8 (1114) Distance between front legs and splashguard 2 3/4 (70) 2 3/4 (70) 2 3/4 (70)
Electrical Service (Electrical Field Wiring connection point)
(B) RH End of case to center of stub up area 36 1/4 (921) 84 1/4 (2140) 132 3/8 (3363)
Back of case to center of stub up area 19 (483) 19 (483) 19 (483) Length of electrical wireway 26 1/2 (673) 26 1/2 (673) 26 1/2 (673)
(C) RH End of case to LH end of wireway 42 1/8 (1070) 90 1/8 (2289) 138 1/4 (3511)
Waste Outlets (One each end)
(D) RH End of case to the center of LH waste outlet 36
1
/4
(921) 84
1
/4
(2140) 132
3
/8
(3363)
RH End of case to the center of RH waste outlet 12
1
/8 (307) 12 1/8 (307) 12 1/8 (307) Back O/S of case to center of waste outlets 26 3/4 (680) 26 3/4 (680) 26 3/4 (680) Schedule 40 PVC drip pipe 1 1/4 (32) 1 1/4 (32) 1 1/4 (32)
Refrigeration Outlet
Back of case to center of refrigeration outlet 21 1/4 (540) 21 1/4 (540) 21 1/4 (540) RH end of case to center of refrigeration outlet 8 (203) 8 (203) 8 (203)
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/4 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
7
/8
Wireway
3 of 9P/N 0463872_F
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
REFRIGERATION DATA
Note: This data is based on store temperature and
humidity that does not exceed 75°F and 55% R.H.
D6NX-LEP UNLIT LIT PEG*
Discharge Air °F 33 31 31
Evaporator °F 28 26 26
Unit Sizing °F 26 24 24
Btu/hr/ft
— Unlit Shelves
‡‡
D6NX-LEP Parallel Conventional
U
NLIT 1545 1610
P
EG* 1690 1765
* Hussmann Peg Shelves (Deli only).
Optional energy efficient motors reduce the
refrigeration load by 55 Btu/hr/ft.
‡‡
Add 10 Btu/hr/ft per shelf row for LED fixtures.
Add 20 Btu/hr/ft per shelf row for fluorescent lamps.
DEFROST DATA
Frequency Hr 12
Defrost Water (lb/ft/day) 10.5
(± 15% based on case configuration and
product loading).
OFFTIME D6NX-LEP
Temp Term °F 48
Failsafe Minutes 30
E
LECTRIC OR G
AS
Not Recommended
CONVENTIONAL CONTROLS
Low Pressure Backup Control
CI/CO** D6NX-LEP
19°F / 9°F
Indoor Unit Only, Pressure Defrost
Termination** 48°F
**Use a Temperature Pressure Chart to
determine PSIG conversions.
Estimated Charge ** D6NX-LEP
4 ft 1.9 lb 30 oz 0.9 kg
8 ft 3.7 lb 59 oz 1.7 kg
12 ft 5.1 lb 82 oz 2.3 kg
**This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound.
26 3/4 (680)
4 3/4
(120)
25 1/4 (641)
37 (940)
28 7/8 (734)
25 3/8
(644)
66 5/8
(1693)
34 5/8
(878)
FAN
C O
I
L
17 1/4
(438)
3 In.
(77 mm)
Required
Air Gap
87
(2220)
7 1/4 (183)
19 5/8
(499)
3 5/8
(92)
21 1/4 (540)
6
(152)
60
(1524)
Electrical
Case to Case
Connections
12 1/4
(311)
Refrigeration
Outlet
Impact
Excel
D6NX-LEP
Dairy & Delicatessen
Dimensions shown as in. and (mm).
Multi-deck, Narrow Footprint, 6 Display Levels, Low Front
D6NX-LEP
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.