Hussmann D5X-URLE Specifications

Item Part # Description Wiring Item #
FAN ASSEMBLIES 8 Ft & 12 Ft
A. 13W Standard Fan Assembly — Discharge (1)
0378349 Fan Motor, Discharge
(MO.4410104)
0463643 Fan Blade (FB.4780648) 13W Energy Efficient Fan Assembly — Discharge 0477656 Fan Motor, Discharge
(MO.4410547)
0463643 Fan Blade (FB.4780648)
8 Ft & 12 Ft
0047000 Fan Motor, Return
(MO.4410103)
0315470 Fan Blade (FB.0315470) 12W Energy Efficient Fan Assembly — Return 0477655 Fan Motor, Return
(MO.4410546)
0315470 Fan Blade (FB.0315470)
Item Part # Description Wiring Item #
THERMOSTATS
C. Optional Adjustable Refrigeration Thermostat (3)
L
AMPS AND BALLASTS
D. Ballast, Electronic (4)
0480130 2 lamps (BA.4481676) 0480131 3 lamps (BA.4481654) 0480132 4 lamps (BA.4481677)
E. Fluorescent Lamp (5)
Replace with like fixtures
LED F
IXTURES AND POWER SUPPLY
F. 0501213 Power Supply (EP.4481861) (6)
G. LED Canopy Fixture (7)
Replace with like fixtures — See Page 5.
B
F
C
A
G
D
E
D5X-URLE
Technical Data Sheet
P/N 0512029_B
NSF
®
Certified
March 2010
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
©2010 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
ONE FLOOR DRAIN IS
REQUIRED FOR EACH CASE.
IMPORTANT
P/N_0512029_B
Note: Revision B adds Btu note (page 3), EcoShine LED (page 4) and parts (page 5), and revises canopy wiring diagram (page 6). Other changes marked by bar, underline or circle.
8 ft 12 ft
General
(A) Case Length (without ends or partitions) 96 3/8 (2448) 144 1/2 (3670)
(Each end and insulated partition adds 1 1/
2 in. (38 mm) to case line up.)
Maximum O/S dimension of case back to front 51 5/8 (1311) 51 5/8 (1311)
(front of canopy through cooler wall not including electrical box)
Cooler wall to front of splashguard 43 3/
4 (1111) 43
3
/
4 (1111)
Cooler wall to O/S edge of front rails 40
3
/4 (1035) 40 3/4 (1035) Distance between edges of external rails and center rails 41 1/2 (1054) 41 1/2 (1054) Distance between edges of center rails NA 43 7/8 (1114) Distance between front rails and splashguard 7 3/4 (197) 7 3/4 (197)
Electrical Service (Electrical Field Wiring connection point located on top of case)
(B) RH End of case to center of 4 x 4 x 2 Electrical Box 2 (51) 2 (51)
Back of case (cooler wall) to center of 4 x 4 x 2 Electrical Box 2 1/4 (57) 2 1/4 (57)
Waste Outlets (One each end)
(C) RH End of case to the center of LH waste outlet 84 1/4 (2140) 132 3/8 (3363)
RH End of case to the center of RH waste outlet 12 1/8 (308) 12 1/8 (308) Cooler wall to center of waste outlets 42 (1067) 42 (1067) Schedule 40 PVC drip pipe 1 1/4 (32) 1 1/4 (32)
Refrigeration Outlet
Cooler wall to center of refrigeration outlet 4 1/4 (108) 4 1/4 (108)
(D) RH end of case to center of refrigeration outlet 93 1/4 (2369) 141 3/8 (3591)
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
D5X-URLE Technical Data Sheet
2 of 9
Engineering
Plan Views
B
Front
C
L
Upper Electrical
Box
Upper Refrigeration Outlet
A
Cooler Wall
Canopy
Bumper
Waste Outlet
43
(1092)
C
12 1/8
(308)
Splashguard
Waste Outlet
D
Dimensions shown as in. & (mm).
Rear Load
Ultra Low Front Dairy
07-2009
Note: ALL FIELD WIRING CONNECTION POINTS ARE ABOVE THE CASE. Case to case connections are made in the electrical box at the top of the case.
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/4 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
7
/8
REFRIGERATION DATA
Note: This data is based on store temperature and
humidity that does not exceed 75°F and 55% R.H.
D5X-URLE
Discharge Air (°F) 27
Evaporator (°F) 21
Unit Sizing (°F) 19
Important Note: Btu numbers are for the
D5X-URLE when installed to a cooler
operating at a 36°F air temperature. The unit
cooler coil must be sized for an additional
load of 1160 Btu/hr/ft of D5X-URLE case
installed to the cooler.
Btu/hr/ft
D5X-URLE
Parallel
1200
Conventional
1375
Optional energy efficient motors reduce the
refrigeration load by 70 Btu/hr/ft.
DEFROST DATA
D5X-URLE
Frequency (hr) 6
Defrost Water (lb/ft/day) 6
(± 15% based on case configuration and
product loading).
OFFTIME D5X-URLE
Time Terminated (minutes) 45
ELECTRIC OR GAS Not Recommended
Standard Defrost Thermostat — NA
CONVENTIONAL CONTROLS
Low Pressure Backup Control
D5X-URLE
CI/CO (Temp °F)* 14 / 4
Indoor Unit Only, Pressure Defrost
Termination (Temp °F)* NA
*Use a Temperature Pressure Chart to
determine PSIG conversions.
Estimated Charge ** D5X-URLE
8 ft 2.7 lb 43 oz 1.2 kg
12 ft 3.9 lb 62 oz 1.8 kg
**This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound.
P/N 0512029_B
Fan
Coil
Fan
40 7/8 (1038)
41 5/8 (1057)
45 3/8 (1153)
34 7/8 (886)
33 7/8 (860)
24 5/8 (626)
6 3/8
(162)
51 5/8 (1311)
79
(2007)
83 3/4
(2127)
4 1/8 (106)
7 1/4
(184)
11 1/2
(292)
86
(2184)
10 1/4
(260)
12 3/4
(324)
3 (76)
29 7/8 (758)
61 3/4
(1568)
2 1/8
(54)
C O O
L E
R
W A
L L
3 3/4
(95)
64 3/8
(1635)
Dimensions shown as in. & (mm).
Ultra Low Front, Rear Load
3 of 9
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Impact
Excel
D5X-URLE
Dairy
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.
ALL FIELD WIRING CONNECTION POINTS ARE ABOVE THE CASE.
D5X-URLE
Electrical Data
Number of Fans 8 ft 12 ft
Discharge — 13W 4 6 Return — 12W 4 6 Return — 7W ——
Amperes Watts
8 ft 12 ft 8 ft 12 ft
Discharge Fan
120V 60Hz Standard 3.08 4.62 244 366 120V 50Hz Standard 3.92 5.88 280 420 230V 60Hz Export 1.56 2.34 244 366 230V 50Hz Export 1.92 2.88 280 420 120V 60Hz Energy Efficient 1.20 1.80 80 120 230V 60Hz Energy Efficient 0.60 0.90 80 120
Return Fan
120V 60Hz Standard 2.60 3.90 200 300 120V 50Hz Standard 3.00 4.50 228 342 230V 60Hz Export 1.32 1.98 200 300 230V 50Hz Export 1.52 2.28 228 342 120V 60Hz Energy Efficient 1.20 1.80 72 108 230V 60Hz Energy Efficient 0.60 0.90 72 108
Minimum Circuit Ampacity
120V 60Hz Standard 5.88 8.72 120V 50Hz Standard 7.12 10.58 230V 60Hz Export 3.08 4.52 230V 50Hz Export 3.64 5.36 120V 60Hz Energy Efficient 2.60 3.80 230V 60Hz Energy Efficient 1.40 2.00
Maximum Over Current Protection 120V 20 20
Maximum Over Current Protection 230V 15 15
Standard Lighting (T-8 fluorescent)
1 Row Canopy 0.51 0.77 59 85
Optional Lighting (T-8 fluorescent)
Additional 1 Row Canopy 0.51 0.77 59 85 Additional 2 Row Canopy 1.02 1.54 118 170 1 Row Rail Light 0.51 0.77 59 85
EcoShine Multi-deck — Normal CRI—120VAC, 50/60Hz
2 Row Canopy (Front & Rear) 0.55 0.82 66 98
EcoShine Multi-deck — High CRI —120VAC, 50/60Hz
2 Row Canopy (Front & Rear) 0.63 0.93 75 112
Always*Bright Multi-deck —120VAC, 50/60Hz
2 Row Canopy 0.71 1.08 85 130
Lighted shelves are not available for rear-load models.
120V Lighting Circuit Total = Standard Lighting + Total Optional Lighting + Optional Shelf Lighting 230V Lighting Circuit Total = Multiply 120V Lighting Circuit Total by 0.52
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
D5X-URLE Technical Data Sheet
4 of 9
Impact
Excel
D5X-URLE
Dairy
5 of 9P/N 0512029_B
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
ESTIMATED SHIPPING WEIGHT
4
Case Solid End
8 ft 12 ft (each)
lb (kg) 970 (440) 1550 (703) 90 (41)
4
Actual weights will vary according to optional kits included.
Product Data
Recommended Usable Cube
1
(Cu Ft/Ft) 10.06 ft3 /ft (0.93 m3 /m)
Total Display Area
2
(Sq Ft/Ft) 5.16 ft2/ft (1.57 m2 /m)
Shelf Area 3(Sq Ft/Ft) 9.83 ft2/ft (3.00 m2 /m)
1
Refrigerated Volume less shelving and other unusable space: Refrigerated Volume/Unit of Length, ft3/ft [m3/m]
2
Total Display Area, ft2[m2]/Unit of Length, ft [m]
3
Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann Product Reference Guide. The standard shelf complement for this model is (4) rows of 22-inch shelves.
Impact
Excel
D5X-URLE
Dairy
PARTS LIST (Continued from Page 1)
Note: Always*Bright lamps will be replaced with the latest generation of EcoShine lamps.
Item Part # Description
LED FIXTURES AND POWER SUPPLY
F. 0501213 Power Supply (EP.4481861) (6)
G. EcoShine LED Canopy Fixture (7)
4441720 Front 48-inch 2900K HCRI 4441722 Front 48-inch 3500K HCRI 4441724 Front 48-inch 3500K 4441726 Front 48-inch 4100K 4441721 Rear 48-inch 2900K HCRI 4441723 Rear 48-inch 3500K HCRI 4441725 Rear 48-inch 3500K 4441727 Rear 48-inch 4100K
Item Part # Description
D5X-URLE Technical Data Sheet
6 of 9
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
Fan Wiring Offtime Defrost
5
5
4
4
5
6
5
5
Optional
Two Row
Canopy
Connector
BL
BL
W
G
R
BL
W
R
R
R
BL
BL
R
BL
R
R
R
BK
BK
Orange or Tan Band
5
4
55
Connector
W
BK
BL
BL
R
BL
R
R
R
BK
8 ft 12 ft
8 ft 12 ft
Ballast Plug for Optional Light Rail (if applied)
W
BK
Field Connections
Case
Ground
Bar
2
120V NEUTRAL
B
ROWN BAND
120V POWER
Fans
1
B
ROWN BAND
Refrigeration
Thermostat
To Condensing Unit
}
Light Blue
3
4 & 6 Discharge Air Fans
2
120V NEUTRAL
B
ROWN BAND
120V POWER
Fans
1
B
ROWN BAND
4 & 6 Return Air Fans
Light Circuits — Fluorescent Fixtures
R = Red Y = Yellow G = Green BL = Blue BK = Black W = White
= 120V P
OWER = 120V NEUTRAL = FIELD GROUND
= CASE GROUND
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
7 of 9P/N 0512029_B
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
R = Red Y = Yellow G = Green BL = Blue BK = Black W = White
= 120V P
OWER = 120V NEUTRAL = FIELD GROUND
= CASE GROUND
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
7
7
7
7
7
7
7
7
7
7
6
6
6
Optional Canopy Lighting
LED Fixtures
D5X-URLE Technical Data Sheet
8 of 9
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
Doors Fully Closed
NOTE: Consult Ultra-Low Front Installation manual for instructions
on connecting the merchandiser
to the cooler.
Rear View of 8 Foot Dairy Merchandiser
62 1/
2
34 3/
4
41 1/
2
74 1/
4
89 7/
8
Doors Fully Opened
9 of 9P/N 0512029_B
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
NOTE: Consult Ultra-Low Front Installation manual
for instructions on connecting the merchandiser
to the cooler.
Rear View of 12 Foot Dairy Merchandiser
41
1
/
2
Doors
Fully Closed
34
3
/
4
Doors
Fully Opened
138
41
1
/
2
Doors
Fully Closed
62
1
/
2
74
1
/
4