Electrical Data
Number of Fans 8 ft 12 ft
Discharge — 13W 4 6
Return — 12W 4 6
Return — 7W ——
Amperes Watts
8 ft 12 ft 8 ft 12 ft
Discharge Fan
120V 60Hz Standard 3.08 4.62 244 366
120V 50Hz Standard 3.92 5.88 280 420
230V 60Hz Export 1.56 2.34 244 366
230V 50Hz Export 1.92 2.88 280 420
120V 60Hz Energy Efficient 1.20 1.80 80 120
230V 60Hz Energy Efficient 0.60 0.90 80 120
Return Fan
120V 60Hz Standard 2.60 3.90 200 300
120V 50Hz Standard 3.00 4.50 228 342
230V 60Hz Export 1.32 1.98 200 300
230V 50Hz Export 1.52 2.28 228 342
120V 60Hz Energy Efficient 1.20 1.80 72 108
230V 60Hz Energy Efficient 0.60 0.90 72 108
Minimum Circuit Ampacity
120V 60Hz Standard 5.88 8.72
120V 50Hz Standard 7.12 10.58
230V 60Hz Export 3.08 4.52
230V 50Hz Export 3.64 5.36
120V 60Hz Energy Efficient 2.60 3.80
230V 60Hz Energy Efficient 1.40 2.00
Maximum Over Current Protection 120V 20 20
Maximum Over Current Protection 230V 15 15
Standard Lighting (T-8 fluorescent)
1 Row Canopy 0.51 0.77 59 85
Optional Lighting (T-8 fluorescent)
Additional 1 Row Canopy 0.51 0.77 59 85
Additional 2 Row Canopy 1.02 1.54 118 170
1 Row Rail Light 0.51 0.77 59 85
EcoShine Multi-deck — Normal CRI—120VAC, 50/60Hz
2 Row Canopy (Front & Rear) 0.55 0.82 66 98
EcoShine Multi-deck — High CRI —120VAC, 50/60Hz
2 Row Canopy (Front & Rear) 0.63 0.93 75 112
Always*Bright Multi-deck —120VAC, 50/60Hz
2 Row Canopy 0.71 1.08 85 130
Lighted shelves are not available for rear-load models.
120V Lighting Circuit Total = Standard Lighting + Total Optional Lighting + Optional Shelf Lighting
230V Lighting Circuit Total = Multiply 120V Lighting Circuit Total by 0.52
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
D5X-URLE Technical Data Sheet
4 of 9
Impact
Excel
D5X-URLE
Dairy