Hussmann D5X-URLE Specifications

Item Part # Description Wiring Item #
FAN ASSEMBLIES 8 Ft & 12 Ft
A. 13W Standard Fan Assembly — Discharge (1)
0378349 Fan Motor, Discharge
(MO.4410104)
0463643 Fan Blade (FB.4780648) 13W Energy Efficient Fan Assembly — Discharge 0477656 Fan Motor, Discharge
(MO.4410547)
0463643 Fan Blade (FB.4780648)
8 Ft & 12 Ft
0047000 Fan Motor, Return
(MO.4410103)
0315470 Fan Blade (FB.0315470) 12W Energy Efficient Fan Assembly — Return 0477655 Fan Motor, Return
(MO.4410546)
0315470 Fan Blade (FB.0315470)
Item Part # Description Wiring Item #
THERMOSTATS
C. Optional Adjustable Refrigeration Thermostat (3)
L
AMPS AND BALLASTS
D. Ballast, Electronic (4)
0480130 2 lamps (BA.4481676) 0480131 3 lamps (BA.4481654) 0480132 4 lamps (BA.4481677)
E. Fluorescent Lamp (5)
Replace with like fixtures
LED F
IXTURES AND POWER SUPPLY
F. 0501213 Power Supply (EP.4481861) (6)
G. LED Canopy Fixture (7)
Replace with like fixtures — See Page 5.
B
F
C
A
G
D
E
D5X-URLE
Technical Data Sheet
P/N 0512029_B
NSF
®
Certified
March 2010
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
©2010 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
ONE FLOOR DRAIN IS
REQUIRED FOR EACH CASE.
IMPORTANT
P/N_0512029_B
Note: Revision B adds Btu note (page 3), EcoShine LED (page 4) and parts (page 5), and revises canopy wiring diagram (page 6). Other changes marked by bar, underline or circle.
8 ft 12 ft
General
(A) Case Length (without ends or partitions) 96 3/8 (2448) 144 1/2 (3670)
(Each end and insulated partition adds 1 1/
2 in. (38 mm) to case line up.)
Maximum O/S dimension of case back to front 51 5/8 (1311) 51 5/8 (1311)
(front of canopy through cooler wall not including electrical box)
Cooler wall to front of splashguard 43 3/
4 (1111) 43
3
/
4 (1111)
Cooler wall to O/S edge of front rails 40
3
/4 (1035) 40 3/4 (1035) Distance between edges of external rails and center rails 41 1/2 (1054) 41 1/2 (1054) Distance between edges of center rails NA 43 7/8 (1114) Distance between front rails and splashguard 7 3/4 (197) 7 3/4 (197)
Electrical Service (Electrical Field Wiring connection point located on top of case)
(B) RH End of case to center of 4 x 4 x 2 Electrical Box 2 (51) 2 (51)
Back of case (cooler wall) to center of 4 x 4 x 2 Electrical Box 2 1/4 (57) 2 1/4 (57)
Waste Outlets (One each end)
(C) RH End of case to the center of LH waste outlet 84 1/4 (2140) 132 3/8 (3363)
RH End of case to the center of RH waste outlet 12 1/8 (308) 12 1/8 (308) Cooler wall to center of waste outlets 42 (1067) 42 (1067) Schedule 40 PVC drip pipe 1 1/4 (32) 1 1/4 (32)
Refrigeration Outlet
Cooler wall to center of refrigeration outlet 4 1/4 (108) 4 1/4 (108)
(D) RH end of case to center of refrigeration outlet 93 1/4 (2369) 141 3/8 (3591)
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
D5X-URLE Technical Data Sheet
2 of 9
Engineering
Plan Views
B
Front
C
L
Upper Electrical
Box
Upper Refrigeration Outlet
A
Cooler Wall
Canopy
Bumper
Waste Outlet
43
(1092)
C
12 1/8
(308)
Splashguard
Waste Outlet
D
Dimensions shown as in. & (mm).
Rear Load
Ultra Low Front Dairy
07-2009
Note: ALL FIELD WIRING CONNECTION POINTS ARE ABOVE THE CASE. Case to case connections are made in the electrical box at the top of the case.
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/4 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
7
/8
REFRIGERATION DATA
Note: This data is based on store temperature and
humidity that does not exceed 75°F and 55% R.H.
D5X-URLE
Discharge Air (°F) 27
Evaporator (°F) 21
Unit Sizing (°F) 19
Important Note: Btu numbers are for the
D5X-URLE when installed to a cooler
operating at a 36°F air temperature. The unit
cooler coil must be sized for an additional
load of 1160 Btu/hr/ft of D5X-URLE case
installed to the cooler.
Btu/hr/ft
D5X-URLE
Parallel
1200
Conventional
1375
Optional energy efficient motors reduce the
refrigeration load by 70 Btu/hr/ft.
DEFROST DATA
D5X-URLE
Frequency (hr) 6
Defrost Water (lb/ft/day) 6
(± 15% based on case configuration and
product loading).
OFFTIME D5X-URLE
Time Terminated (minutes) 45
ELECTRIC OR GAS Not Recommended
Standard Defrost Thermostat — NA
CONVENTIONAL CONTROLS
Low Pressure Backup Control
D5X-URLE
CI/CO (Temp °F)* 14 / 4
Indoor Unit Only, Pressure Defrost
Termination (Temp °F)* NA
*Use a Temperature Pressure Chart to
determine PSIG conversions.
Estimated Charge ** D5X-URLE
8 ft 2.7 lb 43 oz 1.2 kg
12 ft 3.9 lb 62 oz 1.8 kg
**This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound.
P/N 0512029_B
Fan
Coil
Fan
40 7/8 (1038)
41 5/8 (1057)
45 3/8 (1153)
34 7/8 (886)
33 7/8 (860)
24 5/8 (626)
6 3/8
(162)
51 5/8 (1311)
79
(2007)
83 3/4
(2127)
4 1/8 (106)
7 1/4
(184)
11 1/2
(292)
86
(2184)
10 1/4
(260)
12 3/4
(324)
3 (76)
29 7/8 (758)
61 3/4
(1568)
2 1/8
(54)
C O O
L E
R
W A
L L
3 3/4
(95)
64 3/8
(1635)
Dimensions shown as in. & (mm).
Ultra Low Front, Rear Load
3 of 9
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Impact
Excel
D5X-URLE
Dairy
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.