Hussmann D5XRRIS Specifications

B
A
F
C
G
D
E
P/N_0468269_E
D5XRRIS
Technical Data Sheet
NSF
®
Certified
March 2010
Item Part # Description Wiring Item #
F
AN ASSEMBLIES
A. 13W Standard Fan Assembly — Discharge (1)
0378349 Fan Motor, Discharge
(MO.4410104)
0463643 Fan Blade (FB.4780648) 13W Energy Efficient Fan Assembly — Discharge 0477656 Fan Motor, Discharge
(MO.4410547)
0463643 Fan Blade (FB.4780648)
B. 12W Standard Fan Assembly — Return (2)
0047000 Fan Motor, Return
(MO.4410103)
0315470 Fan Blade (FB.0315470) 12W Energy Efficient Fan Assembly — Return 0477655 Fan Motor, Return
(MO.4410546)
0315470 Fan Blade (FB.0315470)
T
HERMOSTATS
C. Optional Adjustable Refrigeration Thermostat (3)
Item Part # Description Wiring Item #
L
AMPS AND BALLASTS
D. Ballast, Electronic (4)
0480130 2 lamps (BA.4481676) 0480131 3 lamps (BA.4481654) 0480132 4 lamps (BA.4481677)
E. Fluorescent Lamp (5)
Replace with like fixtures
LED F
IXTURES AND POWER SUPPLY
F. 0501213 Power Supply (EP.4481861) (6)
G. EcoShine LED Canopy Fixture (7)
4441720 Front 48-inch 2900K HCRI 4441722 Front 48-inch 3500K HCRI 4441724 Front 48-inch 3500K 4441726 Front 48-inch 4100K 4441721 Rear 48-inch 2900K HCRI 4441723 Rear 48-inch 3500K HCRI 4441725 Rear 48-inch 3500K 4441727 Rear 48-inch 4100K
©2010 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
Note: Revision E updates parts list (page 1), and electrical values (page 4).
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
8 ft 12 ft
General
(A) Case Length* 96 3/8 (2448) 144 1/2 (3670)
Maximum O/S dimension of case back to front 53 1/8 (1349) 53 1/8 (1349)
(Front of canopy through cooler wall)
Back of case (cooler wall) to O/S edge of front canopy 47 5/8 (1208) 47 5/8 (1208) Back of case (cooler wall) to O/S edge of front bumper 47 1/2 (1205) 47 1/2 (1205) Back of case (cooler wall) to front of splashguard 44 (1117) 44 (1117)
* Each End and Insulated Partition adds 1 1/2 in. (38 mm) to the length of the lineup.
Electrical Service ** Electrical Field Wiring Connection Point
Back of case (cooler wall) to center of 4x4x2 Electrical box 6 1/4 (159) 6 1/4 (159)
(B) RH End of case to center of 4x4x2 Upper Electrical box 2 1/2 (64) 2 1/2 (64)
Back of case (cooler wall) to center of Lower Electrical box 33 3/4 (857) 33 3/4 (857)
(C) RH End of case to center of Lower Electrical box 3 1/8 (79) 3 1/8 (79)
Waste Outlet
(D) End of case to the center of waste outlet (canopy drip pipe) 1 1/4 (32) 1 1/4 (32)
Outside diameter of the drip pipe
7
/8 (22)
7
/8 (22)
Refrigeration Outlet
Back of case (cooler wall) to center of refrigeration outlet 6 3/4 (171) 6 3/4 (171)
(E) LH end of case to center of refrigeration outlet 3 1/2 (89) 3 1/2 (89)
Outside diameter of the liquid line
3
/8 (10)
3
/8 (10)
Outside diameter of the suction line
7
/8 (22)
7
/8 (22)
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
D5XRRIS Technical Data Sheet 2 of 8
Engineering
Plan Views
NOTE: When joining D5X models with D5XRRI or D5XRRIS models, the drain location for the D5X must be moved forward 2.325 inches (59 mm) to allow fronts to align.
D
Front
C
L
Waste Outlet
Upper Electrical
Box
Upper Refrigeration Outlet
Cooler Wall
D
47 1/2
(1025)
E
6 3/4
(171)
Canopy
Bumper
6
1
/4
(159)
Cart Stop Rail
C
Lower Electrical
Box
A
B
47 5/8
(1028)
33
(838)
33 3/4
(857)
Suspended
Roll-in Rear Load
Dairy
2-2006
PHYSICAL DATA
Merchandiser Drip Pipe (in.)
7
/8
Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
7
/8
Dimensions shown as in. & (mm).
REFRIGERATION DATA
Note: This data is based on store temperature and
humidity that does not exceed 75°F and 55% R.H.
D5XRRIS
Discharge Air (°F) 32
Evaporator (°F) 21
Unit Sizing (°F) 19
Important Note: Btu numbers are for the
D5XRRI when installed to a cooler operating at a 36°F air temperature. The unit cooler coil must be sized for an additional load of 800 Btu/hr/ft of D5XRRI case installed to the cooler.
Btu/hr/ft
D5XRRIS
Roll-in Dairy Carts
Parallel Conventional
U
NLIT 1035 1200
Optional energy efficient motors reduce the
refrigeration load by 70 Btu/hr/ft.
DEFROST DATA
D5XRRIS
Frequency (hr) 6
Defrost Water (lb/ft/day) 6
(± 15% based on case configuration and
product loading).
OFFTIME D5XRRIS
Time Terminated (minutes) 50
ELECTRIC OR GAS Not Recommended
Standard Defrost Thermostat — NA
CONVENTIONAL CONTROLS
Low Pressure Backup Control
D5XRRIS
CI/CO (Temp °F)* 14 / 4
Indoor Unit Only, Pressure Defrost
Termination (Temp °F)* NA
**Use a Temperature Pressure Chart to determine PSIG conversions.
Estimated Charge ** D5XRRIS
8 ft 2.7 lb 43 oz 1.2 kg
12 ft 3.9 lb 62 oz 1.8 kg
**This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound.
P/N 0468269_E
81 3/4
(2077)
Coil
Fan
Fan
D5XRRIS
Cooler Wall
79 5/8
(2022)
32 1/8 (815)
44 3/4 (1137)
46 1/2 (1179)
47 1/2 (1205)
54 3/4
(1390)
17 1/2
(444)
19 7/8
(504)
4 1/2
(115)
34 3/4 (882)
47 5/8 (1208)
10 5/8
(269)
12 5/8
(321)
1
(26)
C O O
L E R
W
A
L
L
4 1/8 (106)
44 (1117)
85 3/4
(2178)
Impact D5XRRIS
Dairy
Dimensions shown as in. & (mm).
Suspended, Roll-in Rear Load
3 of 8
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.