Hussmann D5X-LRE Specifications

D
C
E
B
D
E
E
A
H
F
G
Item Part # Description Wiring Item #
F
AN ASSEMBLIES
A. 12W Standard Fan Assembly (1)
0047000 Fan Motor, Evaporator
(MO.4410103)
0463643 Fan Blade (FB.4780648)
12W Energy Efficient Fan Assembly (1) 0477655 Fan Motor, Evaporator
(MO.4410546)
0463643 Fan Blade (FB.4780648)
6 Ft
A. 12W Standard Fan Assembly (1)
0058698 Fan Motor, Evaporator
(MO.4410102)
0142780 Fan Blade (FB.0142780)
7W Energy Efficient Fan Assembly (1) 0477654 Fan Motor, Evaporator
(MO.4410545)
0142780 Fan Blade (FB.0142780)
Item Part # Description Wiring Item #
T
HERMOSTATS
B. 0411744 Standard Non-adjustable (2)
Defrost Thermostat (CT.0411744)
C. Optional Adjustable Refrigeration Thermostat (3)
L
AMPS AND BALLASTS
D. Ballast, Electronic (4)
0480130 2 lamps (BA.4481676) 0480131 3 lamps (BA.4481654) 0480132 4 lamps (BA.4481677)
E. Fluorescent Lamp (5)
Replace with like fixtures
LED F
IXTURES AND POWER SUPPLY
F. 0501213 Power Supply (EP.4481861) (6)
G. LED Canopy Fixture (7)
Replace with like fixtures — See Page 5.
H. LED Shelf Fixture (8)
Replace with like fixtures — See Page 5.
D5X-LRE
Technical Data Sheet
P/N 0506796_D
NSF
®
Certified
March 2010
Superseded
P/N 0463860_B
©2010 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
Note: Revision D adds Btu note (page 3), EcoShine LED (page 4) and parts (page 5), and revises canopy wiring diagram (page 6). Other changes marked by bar, underline or circle.
P/N_0506796_D
NOTE: Case-to-Case Electrical Connections are made IN FRONT OF SPLASHGUARD.
Splashguard
Waste Outlet
FRONT
3 3/8
(85)
12 1/8 (307)
Electrical Field Connection
5 1/2 (140)
13/8 (35)
4 1/4 (108)
8 (203)
Waste Outlet
B
Refrigeration
Outlet
Electrical
Stub Up Area
6 x 6
(152 x 152)
Wireway
D
A
C
26 1/2
(673)
20
(508)
40 5/8
(1032)
44
(1118)
40 5/8
(1032)
34 7/8
(885)
36 7/8
(937)
29 3/8
(745)
45 1/2
(1155)
2 of 13 D5X-LRE Technical Data Sheet
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
General 4 ft 6 ft 8 ft 12 ft
(A) Case Length (without ends or partitions) 48 3/8
(1229) 72
3
/8
(1838) 96
3
/8
(2448) 144
1
/2
(3670)
(Each end and insulated partition adds 1 1/2 in. (38 mm) to case line up.)
Maximum O/S dimension of case 45 1/2 (1155) 45 1/2 (1155) 45 1/2 (1155) 45 1/2 (1155)
(back to front, including bumper)
Back of case to front of splashguard 36 7/8 (937) 36 7/8 (937) 36 7/8 (937) 36 7/8 (937) Back of case to O/S edge of front skid rail 29 1/2 (749) 29 1/2 (749) 29 1/2 (749) 29 1/2 (749) Width of skid rail 2 3/8
(61) 2
3
/8
(61) 2
3
/8
(61) 2
3
/8
(61)
RH end of case to outside edge of external support 5
1
/2 (140) 5 1/2 (140) 5 1/2 (140) 5 1/2 (140)
Distance between edges of external support
and center support NA 28 5/8
(727) 40
5
/8
(1032) 40
5
/8
(1032) Distance between edges of center supports NA NA NA 44 (1118) Distance between external supports 43
1
/2 (1105) NA NA NA
Distance between front skid rail and splashguard 6 (152) 6 (152) 6 (152) 6 (152)
Electrical Service (Electrical Field Wiring connection point)
(B) RH End of case to center of stub up area 36 1/4 (921) 60 1/4 (1530) 84 1/4 (2140) 132 3/8 (3363)
Back of case to center of stub up area 20 (508) 20 (508) 20 (508) 20 (508) Length of electrical wireway 26 1/
2 (673) 26
1
/
2 (673) 26
1
/
2 (673) 26
1
/
2 (673)
(C) RH End of case to LH end of wireway 42
1
/8 (1070) 66 1/8 (1680) 90 1/8 (2289) 138 1/4 (3511)
Waste Outlets (One each end)
(D) End of case to the center of farthest waste outlet 36 1/4 (921) 60 1/4 (1530) 84 1/4 (2140) 132 3/8 (3363)
End of case to the center of nearest waste outlet 12 1/8 (307) 12 1/8 (307) 12 1/8 (307) 12 1/8 (307) Back O/S of case to center of waste outlets 34 7/8 (885) 34 7/8 (885) 34 7/8 (885) 34 7/8 (885) Outside diameter of the drip pipe 1 1/4 (32) 1 1/4 (32) 1 1/4 (32) 1 1/4 (32)
Refrigeration Outlet
Back of case to center of refrigeration outlet 29 3/8 (745) 29 3/8 (745) 29 3/8 (745) 29 3/8 (745) RH end of case to center of refrigeration outlet 8 (203) 8 (203) 8 (203) 8 (203)
Engineering
Plan Views
Dimensions shown as in. and (mm).
Rear Load Dairy
& Delicatessen
12-2009
D5XR
12 ft plan view is shown.
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/4 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
7
/8
Wireway
REFRIGERATION DATA
Note: This data is based on store temperature and humidity that does not exceed 75°F and 55% R.H.
D5X-LRE
Discharge Air °F 32
Evaporator °F 24
Unit Sizing °F 22
Btu/hr/ft
— Unlit Shelves
‡‡
D5X-LRE Parallel Conventional
U
NLIT
1570 1670
P
EG* 1690 1790
* Hussmann Peg Shelves (Deli only).
Optional energy efficient motors reduce the
refrigeration load by 55 Btu/hr/ft. ‡‡
Add 10 Btu/hr/ft per shelf row for LED fixtures.
Add 20 Btu/hr/ft per shelf row for fluorescent lamps.
DEFROST DATA
Frequency Hrs 6
Defrost Water (lb/ft/day) 10.5
(± 15% based on case configuration and product loading).
OFFTIME D5X-LRE
Temp Term °F 48
Failsafe Minutes 35
E
LECTRIC OR G
AS
Not Recommended
Standard Defrost Thermostat
Close on rise: close 48°F — open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control
CI/CO** D5X-LRE
17°F / 7°F
Indoor Unit Only,
Pressure Defrost Termination** 48°F
**Use a Temperature Pressure Chart to determine PSIG conversions.
Estimated Charge *** D5X-RE
4 ft 1.4 lb 22 oz 0.6 kg
6 ft 1.9 lb 30 oz 0.9 kg
8 ft 2.7 lb 43 oz 1.2 kg
12 ft 3.9 lb 62 oz 1.8 kg
***This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound.
3 of 13
P/N 0506796_D
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
3 (76)
34 7/8 (885)
3 3/8 (85)
43 7/8 (1113)
36 7/8 (937)
29 3/8 (745)
22 1/2
(572)
30 1/8
(766)
61
(1549)
FAN
D5X-LRE
17 3/8
(442)
81 7/8
(2078)
7 1/4 (183)
19 3/4
(503)
3 3/4
(95)
COIL
Electrical
Case to Case
Connections
45 1/2
(1155)
54 3/4
(1390)
6
(152)
Refrigeration Outlet
3 1/8 (79)
45 1/2 (1147)
Impact
Excel
D5X-LRE
Dairy & Delicatessen
Dimensions shown as in. and (mm).
Multi-deck, 5 Display Levels with Sliding Rear Door, Low Front
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.
Electrical Data
4 ft 6 ft 8 ft 12 ft Number of Fans — 12W 2 4 6 Number of Fans — 7W 4
Amperes Watts
4 ft 6 ft 8 ft 12 ft 4 ft 6 ft 8 ft 12 ft Evaporator Fan
120V 60Hz Standard 1.30 2.00 2.60 3.90 100 156 200 300
120V 50Hz Standard 1.50 2.20 3.00 4.50 114 168 228 342
230V 60Hz Export 0.66 1.00 1.32 1.98 100 156 200 300
230V 50Hz Export 0.76 1.12 1.52 2.28 114 168 228 342
120V 60Hz Energy Efficient 0.60 0.76 1.20 1.80 36 56 72 108
230V 60Hz Energy Efficient 0.30 0.40 0.60 0.90 36 56 72 108
Minimum Circuit Ampacity
120V 60Hz Standard 1.50 2.20 2.80 4.10
120V 50Hz Standard 1.70 2.40 3.20 4.70
230V 60Hz Export 0.86 1.20 1.52 2.18
230V 50Hz Export 0.96 1.32 1.72 2.48
120V 60Hz Energy Efficient 0.80 0.96 1.40 2.00
230V 60Hz Energy Efficient 0.50 0.60 0.80 1.10
Maximum Over Current Protection 120V 20 20 20 20
Maximum Over Current Protection 230V 15 15 15 15
Standard Lighting (T-8 fluorescent)
1 Row Canopy 0.26 0.51 0.51 0.77 30 59 59 85
Optional Lighting (T-8 fluorescent)
Additional 1 Row Canopy 0.26 0.51 0.51 0.77 30 59 59 85
Additional 2 Row Canopy 0.51 1.02 1.02 1.54 59 118 118 170
Additional 3 Row Canopy 0.77 1.53 1.53 2.31 89 177 177 255
1 Row Rail Light 0.26 0.51 0.51 0.77 30 59 59 85
4 Rows of Shelves 1.02 2.04 2.04 3.08 118 236 236 340
EcoShine Multi-deck — Normal CRI—120VAC, 50/60Hz
2 Row Canopy (Front & Rear) 0.28 0.41 0.55 0.82 33 49 66 98
4 Rows of Shelves 0.39 0.58 0.78 1.17 47 70 93 140
EcoShine Multi-deck — High CRI —120VAC, 50/60Hz
2 Row Canopy (Front & Rear) 0.32 0.47 0.63 0.93 38 56 75 112
4 Rows of Shelves 0.47 0.70 0.93 1.40 56 84 112 168
Always*Bright Multi-deck —120VAC, 50/60Hz
2 Row Canopy (Front & Rear) 0.38 0.55 0.71 1.08 45 66 85 130
4 Rows of Shelves 0.47 0.68 0.93 1.40 56 82 112 168
120V Lighting Circuit Total = Standard Lighting + Total Optional Lighting + Optional Shelf Lighting
230V Lighting Circuit Total = Multiply 120V Lighting Circuit Total by 0.52
4 of 13 D5X-LRE Technical Data Sheet
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
Impact
Excel
D5X-LRE
Dairy & Delicatessen
Loading...