P/N 0481484_A
D5XELE
& D5XEE
Technical Data Sheet
P/N 0481484_A
NSF
®
Certified
March 2008
We reserve the right to change or
revise specifications and product
design in connection with any
feature of our products. Such
changes do not entitle the buyer to
corresponding changes, improvements,
additions or replacements for
equipment previously sold or shipped.
Item Part # Description Wiring Item #
FAN ASSEMBLIES
A. 12W Standard Fan Assembly (1)
0047000 Fan Motor, Evaporator
(MO.4410103)
0461805 Fan Blade (FB.4780446)
12W Energy Efficient Fan Assembly (1)
0477655 Fan Motor, Evaporator
(MO.4410546)
0461805 Fan Blade (FB.4780446)
T
HERMOSTATS
B. 0411744 Standard Non-adjustable (2)
Defrost Thermostat
(CT.0411744)
C. Optional Adjustable Refrigeration Thermostat (3)
Item Part # Description Wiring Item #
L
AMPS. BALLASTS, LED FIXTURES AND POWER SUPPLY
D. Ballast, Electronic (4)
0480130 2 lamps (BA.4481676)
0480131
3 lamps (BA.4481654)
0480132
4 lamps (BA.4481677)
E. Fluorescent Lamp (5)
Replace with like fixtures
F. 0501213 Power Supply (EP.4481861) (6)
G. LED Fixture (7)
Replace with like fixtures
©2008 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
Note: Revision A changes ballast (Page 1); adds optional LED lighting (Pages 1, 3, 4, 8); adds capacity and weight (Page 5).
D5XELE and D5XEE
General
Case Length . . . . . . . . . . . . . . . . . . . . . 89
1
/2 (2273)
Maximum O/S dimension of case
back to front
(includes bumper) . . . . . . . .42
1
/2 (1073)
Back of case to front of splashguard . . . 33
1
/2 (851)
Distance between edges of external legs
and center leg . . . . . . . . . . . . . . . . . . . 28
3
/
8 (721)
Distance between front legs
and splashguard . . . . . . . . . . . . . . . . . . 2
3
/4 (70)
Electrical Service
(Electrical Field Wiring connection point)
RH End of case to center of stubup area 68
3
/4 (1476)
Back O/S edge of case to center of
stubup area . . . . . . . . . . . . . . . . . . . . . . . . 24 (612)
Length of
electrical wireway . . . . . . . . . . . . . . . . 26
1
/2 (373)
Waste Outlet
Back O/S of case to center of
waste outlet . . . . . . . . . . . . . . . . . . . . 31
5
/8 (803)
RH End of case to center of
LH waste outlet . . . . . . . . . . . . . . . . . 73
1
/2 (1869)
RH End of case to center of
RH waste outlet . . . . . . . . . . . . . . . . . . . . 16 (406)
Schedule 40 PVC drip pipe . . . . . . . . . . . 1
1
/4 (32)
Refrigeration Outlet
Back of case to center of
refrigeration outlet . . . . . . . . . . . . . . . 31
5
/8 (803)
LH end of case to center of
refrigeration outlet . . . . . . . . . . . . . . . 71
1
/
2 (1816)
2 of 9
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
D5XELE / D5XEE Technical Data Sheet
Dimensions shown as in. and (mm).
Engineering
Plan Views
Multi-deck Dairy &
Delicatessen
End Case
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/4
Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
7
/8
81 3/4
(2077)
17 1/4
(438)
Electrical
Field
Connection
24
(612)
11 7/8
(302)
16
(406)
3 (76)
20 3/4
(527)
Wireway
26 1/2
(373)
Front View
89 1/2 (2273)
28 3/8
(721)
Electrical
Stub Up Area
6 x 6
(152x152)
Waste Outlet
C
L
FRONT
3 (76)
28 3/8
(721)
Refrigeration
Outlet
Waste Outlet
Splashguard
3 (76)
18 1/2
(470)
11 7/8
(302)
16
(406)
4 3/4 (120)
26 1/4
(667)
31 5/8
(803)
33 1/2
(851)
42 1/4
(1073)
NOTE: Case-to-Case
Electrical Connections
are made IN FRONT OF
SPLASHGUARD.
REFRIGERATION DATA
Note: This data is based on store temperature and
humidity that does not exceed 75°F and 55% R.H.
D5XELE D5XEE
Discharge Air (°F) 32 32
Evaporator (°F) 24 24
Unit Sizing (°F) 22 22
Btu/hr/case — Unlit Shelves
D5XELE
‡‡
Parallel Conventional
U
NLIT 10,700 11,400
‡‡
Add 10 Btu/hr/ft per shelf row for LED fixtures.
Add 20 Btu/hr/ft per shelf row for fluorescent lamps.
Btu/hr/case — Unlit Shelves
D5XEE
‡‡
Parallel Conventional
U
NLIT 10,170 10,830
‡‡
Add 10 Btu/hr/ft per shelf row for LED fixtures.
Add 20 Btu/hr/ft per shelf row for fluorescent lamps.
DEFROST DATA
D5XELE D5XEE
Frequency (hr) 66
Defrost Water (lb/ft/day) 10.5 10.5
(± 15% based on case configuration and
product loading).
OFFTIME D5XELE D5XEE
Temp Term (Deg. F) 48 48
Failsafe (minutes) 35 35
G
AS OR ELECTRIC
Not Recommended
Standard Defrost Thermostat
Close on rise: close 48°F — open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control
D5XELE D5XEE
CI/CO (Temp Deg. F)* 17/ 7 17/ 7
Indoor Unit Only, Pressure Defrost
Termination (Temp °F)*
Not Recommended
*Use a Temperature Pressure Chart to
determine PSIG conversions.
Estimated Charge (lb)**
D5XELE 2.4
D5XEE 2.4
**This is an average for all refrigerant types.
Actual refrigerant charge may vary by
approximately half a pound.
3 of 9
P/N 0481484_A
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
31 5/8 (804)
4 3/4 (120)
30 1/4 (768)
42 (1064)
33 1/2 (851)
30 1/4
(768)
61
(1549)
42
(1064)
54 7/8
(1393)
FAN
C
O
I
L
D5XELE
17 1/4
(438)
81 3/4
(2077)
7 1/4 (183)
19 5/8
(499)
3 5/8
(92)
26 1/4 (665)
Refrigeration
Outlet
4 7/8
(123)
Electrical
Case to Case
Connections
17 1/8
(436)
Impact
Excel
D5XELE / D5XEE
Dairy & Delicatessen
Dimensions shown as in. and (mm).
End Case, Multi-deck, 5 Display Levels
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF
(National Sanitation Foundation) Standard #7 requirements for
construction, materials & cleanability.
D5XEE
50 7/8
(1292)
23 5/8
(600)
21 1/4
(540)