Hussmann D5XEE Specifications

B
C
A
D
D
E
E
E
H
F
G
P/N_0481484_D
D5XELE
& D5XEE
P/N 0481484_D
NSF
®
Certified
March 2010
Item Part # Description Wiring Item #
FAN ASSEMBLIES
A. 12W Standard Fan Assembly (1)
0047000 Fan Motor, Evaporator
(MO.4410103)
0461805 Fan Blade (FB.4780446) 12W Energy Efficient Fan Assembly (1) 0477655 Fan Motor, Evaporator
(MO.4410546)
0461805 Fan Blade (FB.4780446)
T
HERMOSTATS
B. 0411744 Standard Non-adjustable (2)
Defrost Thermostat (CT.0411744)
C. Optional Adjustable Refrigeration Thermostat (3)
Item Part # Description Wiring Item #
L
AMPS AND BALLASTS
D. Ballast, Electronic (4)
0480130 2 lamps (BA.4481676) 0480131 3 lamps (BA.4481654) 0480132 4 lamps (BA.4481677)
E. Fluorescent Lamp (5)
Replace with like fixtures
LED F
IXTURES AND POWER SUPPLY
F. 0501213 Power Supply (EP.4481861) (6)
G. LED Canopy Fixture (7)
Replace with like fixtures — See Page 5.
H. LED Shelf Fixture (8)
Replace with like fixtures — See Page 5.
©2010 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
Note: Revision D adds EcoShine LED (page 4) and parts (page 5), and revises canopy wiring diagram (page 6). Other changes marked by bar, underline or circle.
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
D5XELE and D5XEE General
Case Length . . . . . . . . . . . . . . . . . . . . . 89
1
/2 (2273)
Maximum O/S dimension of case
back to front
(includes bumper) . . . . . . . .42
1
/2 (1073)
Back of case to front of splashguard . . . 33
1
/2 (851)
Distance between edges of external legs
and center leg . . . . . . . . . . . . . . . . . . . 28
3
/
8 (721)
Distance between front legs
and splashguard . . . . . . . . . . . . . . . . . . 2
3
/4 (70)
Electrical Service
(Electrical Field Wiring connection point)
RH End of case to center of stub up area 68
3
/4 (1476)
Back O/S edge of case to center of
stub up area . . . . . . . . . . . . . . . . . . . . . . . 24 (612)
Length of
electrical wireway . . . . . . . . . . . . . . . . 26
1
/2 (373)
Waste Outlet
Back O/S of case to center of
waste outlet . . . . . . . . . . . . . . . . . . . . 31
5
/8 (803)
RH End of case to center of
LH waste outlet . . . . . . . . . . . . . . . . . 73
1
/2 (1869)
RH End of case to center of
RH waste outlet . . . . . . . . . . . . . . . . . . . . 16 (406)
Schedule 40 PVC drip pipe . . . . . . . . . . . 1
1
/4 (32)
Refrigeration Outlet
Back of case to center of
refrigeration outlet . . . . . . . . . . . . . . . 31
5
/8 (803)
LH end of case to center of
refrigeration outlet . . . . . . . . . . . . . . . 71
1
/
2 (1816)
2 of 10
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
D5XELE / D5XEE Technical Data Sheet
28 3/8 (721)
16
(406)
28 3/8 (721)
11 7/8 (302)
11 7/8 (302)
89 1/2 (2273)
3 (76)
42 1/4
(1073)
33 1/2 (851)
26 1/4 (667)
31 5/8 (803)
4 3/4 (120)
16
(406)
20 3/4 (527)
18 1/2 (470)
Splashguard
NOTE: Case-to-Case Electrical Connections are made IN FRONT OF SPLASHGUARD.
Electrical
Stub Up Area
6 x 6
(152x152)
Waste Outlet
FRONT
Electrical Field Connection
24
(612)
Waste Outlet
Refrigeration
Outlet
26 1/2 (373)
3 (76)
3 (76)
C
L
Wireway
Front View
17 1/4 (438)
81 3/4
(2077)
Dimensions shown as in. and (mm).
Engineering
Plan Views
Multi-deck Dairy &
Delicatessen
End Case
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/4 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
7
/8
Wireway
REFRIGERATION DATA
Note: This data is based on store temperature and humidity that does not exceed 75°F and 55% R.H.
D5XELE D5XEE
Discharge Air (°F) 32 32 Evaporator (°F) 24 24 Unit Sizing (°F) 22 22
Btu/hr/case
— Unlit Shelves
‡‡
D5XELE Parallel Conventional U
NLIT 10,700 11,400
Optional energy efficient motors reduce the
refrigeration load by 218 Btu/hr/case.
‡‡
Add 10 Btu/hr/ft per shelf row for LED fixtures.
Add 20 Btu/hr/ft per shelf row for fluorescent lamps.
Btu/hr/case‡— Unlit Shelves
‡‡
D5XEE Parallel Conventional U
NLIT 10,170 10,830
Optional energy efficient motors reduce the
refrigeration load by 218 Btu/hr/case.
‡‡
Add 10 Btu/hr/ft per shelf row for LED fixtures.
Add 20 Btu/hr/ft per shelf row for fluorescent lamps.
DEFROST DATA
D5XELE D5XEE
Frequency (hr) 66 Defrost Water (lb/ft/day) 10.5 10.5
(± 15% based on case configuration and
product loading).
OFFTIME D5XELE D5XEE
Temp Term (Deg. F) 48 48 Failsafe (minutes) 35 35
G
AS OR ELECTRIC Not Recommended
Standard Defrost Thermostat
Close on rise: close 48°F — open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control
D5XELE D5XEE
CI/CO (Temp Deg. F)* 17/ 7 17/ 7
Indoor Unit Only, Pressure Defrost Termination (Temp °F)*
Not Recommended
*Use a Temperature Pressure Chart to determine PSIG conversions.
Estimated Charge (lb)** D5XELE 2.4 D5XEE 2.4
**This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound.
3 of 10
P/N 0481484_D
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
31 5/8 (804)
4 3/4 (120)
30 1/4 (768)
42 (1064)
33 1/2 (851)
30 1/4
(768)
61
(1549)
42
(1064)
54 7/8
(1393)
FAN
C O
I
L
D5XELE
17 1/4
(438)
81 3/4
(2077)
7 1/4 (183)
19 5/8
(499)
3 5/8
(92)
26 1/4 (665)
Refrigeration Outlet
6
(152)
Electrical
Case to Case
Connections
17 1/8
(436)
Impact
Excel
D5XELE / D5XEE
Dairy & Delicatessen
Dimensions shown as in. and (mm).
End Case, Multi-deck, 5 Display Levels
D5XEE
21 1/4
(540)
23 5/8
(600)
50 7/8
(1292)
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.
Loading...
+ 7 hidden pages