REFRIGERATION DATA
Note: This data is based on store temperature and
humidity that does not exceed 75°F and 55% R.H.
D5XELE D5XEE
Discharge Air (°F) 32 32
Evaporator (°F) 24 24
Unit Sizing (°F) 22 22
Btu/hr/case
‡
— Unlit Shelves
‡‡
D5XELE Parallel Conventional
U
NLIT 10,700 11,400
‡
Optional energy efficient motors reduce the
refrigeration load by 218 Btu/hr/case.
‡‡
Add 10 Btu/hr/ft per shelf row for LED fixtures.
Add 20 Btu/hr/ft per shelf row for fluorescent lamps.
Btu/hr/case‡— Unlit Shelves
‡‡
D5XEE Parallel Conventional
U
NLIT 10,170 10,830
‡
Optional energy efficient motors reduce the
refrigeration load by 218 Btu/hr/case.
‡‡
Add 10 Btu/hr/ft per shelf row for LED fixtures.
Add 20 Btu/hr/ft per shelf row for fluorescent lamps.
DEFROST DATA
D5XELE D5XEE
Frequency (hr) 66
Defrost Water (lb/ft/day) 10.5 10.5
(± 15% based on case configuration and
product loading).
OFFTIME D5XELE D5XEE
Temp Term (Deg. F) 48 48
Failsafe (minutes) 35 35
G
AS OR ELECTRIC Not Recommended
Standard Defrost Thermostat
Close on rise: close 48°F — open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control
D5XELE D5XEE
CI/CO (Temp Deg. F)* 17/ 7 17/ 7
Indoor Unit Only, Pressure Defrost
Termination (Temp °F)*
Not Recommended
*Use a Temperature Pressure Chart to
determine PSIG conversions.
Estimated Charge (lb)**
D5XELE 2.4
D5XEE 2.4
**This is an average for all refrigerant types.
Actual refrigerant charge may vary by
approximately half a pound.
3 of 10
P/N 0481484_D