Hussmann D5RRI Technical Data Sheet

B
D
C
E
A
P/N 0435043B
®
Item Part # Description Wiring Item #
FAN ASSEMBLIES AND THERMOSTATS
(MO.4410104)
0315470 Fan Blade
(FB.0315470)
B. 0047000 Fan Motor, Return (2)
(MO.4410103)
0315470 Fan Blade (F B.0315470)
C. 0137880 Optional Adjustable (3)
Refrigeration Thermostat (CT.4481084)
Item Part # Description Wiring Item #
LAMPS AND BALLASTS
D. 0428648 Ballast, 2 lamp Electronic
(BA.4480823) (4)
D. 0428649 Ballast, 3 lamp Electronic
(BA.0428649) (4)
E. Fluorescent Lamp (5)
Replace with like fixtures
D5RRI
Technical Data Sheet
P/N 0435043B
NSF
®
Certified
June 2006
©2006 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
Rev. B added NSF certification & Aftermarket part numbers.
Merchandisers
8 ft 12 ft
General
(A) Case Length* 96 3/8 (2448) 144 1/2 (3670)
Maximum O/S dimension of case back to front 53 1/8 (1349) 53 1/8 (1349)
(Note: Includes bumper and wall)
Back of case to O/S edge of front bumper 48 7/8 (1241) 48 7/8 (1241) Back of case to front of splashguard 44 (1118) 44 (1118)
* Each End and Insulated Partition adds 1 1/2 in. (38 mm) to the length of the lineup.
Electrical Service ** Electrical Field Wiring Connection Point
Back of case (wall) to center of 4x4x2 Electrical box 7 5/8 (195) 7 5/8 (195)
(B) RH End of case to center of 4x4x2 Upper Electrical box 2 1/2 (64) 2 1/2 (64) (C) RH End of case to center of Lower Electrical box 3 1/8 (79) 3 1/8 (79)
Waste Outlet
(D) End of case to the center of waste outlet 1 1/4 (32) 1 1/4 (32)
Outside diameter of the drip pipe
7
/8 (22)
7
/8 (22)
Refrigeration Outlet
Back of case (wall) to center of refrigeration outlet 6 3/4 (171) 6 3/4 (171)
(E) LH end of case to center of refrigeration outlet 3 1/2 (89) 3 1/2 (89)
Outside diameter of the liquid line
3
/8 (10)
3
/8 (10)
Outside diameter of the suction line
7
/8 (22)
7
/8 (22)
D5RRI Technical Data Sheet 2 of 6
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Engineering
Plan Views
Roll-in Rear Load
Dairy
3-2003
Dimensions shown as in. & (mm).
NOTE: When joining D5 models with D5RRI or D5RRIS models, the drain location for the D5 must be moved forward 2.325 inches (59 mm) to allow fronts to align.
D
Cooler Wall
Cart Stop Rail
Bumper
6
(171)
Canopy
3
/4
E
A
B
Waste
Upper Refrigeration Outlet
C
Outlet
Upper Electrical
Box
Lower Electrical
Box
L
D
5
7
/8
(195)
34 1/8
(867)
3
/4
47
(1214)
7
/8
9
(251)
53 1/8
(1349)
C
Front
Loading...
+ 4 hidden pages