D5NX-LEP
Technical Data Sheet
NSF
®
Certified
March 2010
Item Part # Description Wiring Item #
F
AN ASSEMBLIES
4 Ft, 8 Ft & 12 Ft
A. 12W Standard Fan Assembly (1)
0047000 Fan Motor, Evaporator
(MO.4410103)
0461805 Fan Blade (FB.4780446) 12W Energy Efficient Fan Assembly (1) 0477655 Fan Motor, Evaporator
(MO.4410546)
0461805 Fan Blade (FB.4780446)
6 Ft Only
A. 7W Standard Fan Assembly (1)
0058698 Fan Motor, Evaporator
(MO.4410102)
0142780 Fan Blade (FB.0142780) 7W Energy Efficient Fan Assembly (1) 0477654 Fan Motor, Evaporator
(MO.4410545)
0142780 Fan Blade (FB.0142780)
Item Part # Description Wiring Item #
T
HERMOSTATS
B. Optional Adjustable Refrigeration Thermostat (2)
L
AMPS AND BALLASTS
C. Ballast, Electronic (3)
0480130 2 lamps (BA.4481676) 0480131 3 lamps (BA.4481654) 0480132 4 lamps (BA.4481677)
D. Fluorescent Lamp (4)
Replace with like fixtures
LED F
IXTURES AND POWER SUPPLY
E. 0501213 Power Supply (EP.4481861) (5)
F. LED Canopy Fixture (6)
Replace with like fixtures — See Page 5.
G. LED Shelf Fixture (7)
Replace with like fixtures — See Page 5.
©2010 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
Note: Rev. I adds Btu note (page 3), and EcoShine LED (page 4) and parts (page 5), and revises canopy wiring diagram (page 6). Other changes marked by underline or circle.
2 of 9 D5NX-LEP Technical Data Sheet
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
Engineering
Plan Views
Dimensions shown as in. and (mm).
Narrow Dairy &
Delicatessen
05-2006
Wireway
26 3/4
(680)
25 1/4
(641)
37
(940)
A
41 1/2
(1054)
28 1/2
(724)
3 In.
(77 mm)
Required
Air Gap
Refrigeration
Outlet
Waste Outlet
Waste Outlet
FRONT
4 3/4 (120)
21 1/4
(540)
D
C
8 (203)
12 1/8 (307)
4 1/4 (108)
41 1/2
(1054)
43 7/8
(1114)
B
Splashguard
19
(483)
NOTE: Case-to-Case Electrical Connections are made IN FRONT OF SPLASHGUARD.
Electrical
Stub Up Area
6 x 6
(152x152)
Electrical Field Connection
26 1/2
(673)
4 3/4 (120)
4 1/2 (115)
D5NX
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/4 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
7
/8
4 ft 6 ft 8 ft 12 ft
General
(A) Case Length (without ends or partitions) 48 3/8
(1229) 72
3
/8
(1838) 96
3
/8
(2448) 144
1
/2
(3670)
(Each end and insulated partition adds 1 1/2 in. (38 mm) to case line up.)
Maximum O/S dimension of case back to front
(includes bumper) 37 (940) 37 (940) 37 (940) 37 (940)
Back of case to front of splashguard 28 1/2 (724) 28 1/2 (724) 28 1/2 (724) 28 1/2 (724) Back of case to O/S edge of front leg 25 1/4 (641) 25 1/4 (641) 25 1/4 (641) 25 1/4 (641) Distance between edges of external legs and center legs NA 29 1/2
(750) 41
1
/2
(1054) 41
1
/2
(1054)
Distance between edges of center legs NA NA NA 43
7
/8 (1114)
Distance between front legs and splashguard 2 3/4 (70) 2 3/4 (70) 2 3/4 (70) 2 3/4 (70)
Electrical Service (Electrical Field Wiring connection point)
(B) RH End of case to center of stub up area 36 1/4 (921) 60 1/4 (1530) 84 1/4 (2140) 132 3/8 (3363)
Back of case to center of stub up area 19 (483) 19 (483) 19 (483) 19 (483) Length of electrical wireway 26 1/2 (673) 26 1/2 (673) 26 1/2 (673) 26 1/2 (673)
(C) RH End of case to LH end of wireway 42 1/8 (1070) 66 1/8 (1680) 90 1/8 (2289) 138 1/4 (3511)
Waste Outlets (One each end)
(D) RH End of case to the center of LH waste outlet 36
1
/4
(921) 60
1
/4
(1530) 84
1
/4
(2140) 132
3
/8
(3363)
RH End of case to the center of RH waste outlet 12
1
/8 (307) 12 1/8 (307) 12 1/8 (307) 12 1/8 (307) Back O/S of case to center of waste outlets 26 3/4 (680) 26 3/4 (680) 26 3/4 (680) 26 3/4 (680) Schedule 40 PVC drip pipe 1 1/4 (32) 1 1/4 (32) 1 1/4 (32) 1 1/4 (32)
Refrigeration Outlet
Back of case to center of refrigeration outlet 21 1/4 (540) 21 1/4 (540) 21 1/4 (540) 21 1/4 (540) RH end of case to center of refrigeration outlet 8 (203) 8 (203) 8 (203) 8 (203)
Wireway
REFRIGERATION DATA
Note: This data is based on store temperature and
humidity that does not exceed 75°F and 55% R.H.
D5NX-LEP Unlit Lit
Discharge Air (°F) 32 30
Evaporator (°F) 28 26
Unit Sizing (°F) 26 24
Btu/hr/ft
— Unlit Shelves
‡‡
D5NX-LEP Parallel Conventional
U
NLIT
1390 1470
Optional energy efficient motors reduce the
refrigeration load by 27 Btu/hr/ft. ‡‡
Add 10 Btu/hr/ft per shelf row for LED fixtures.
Add 20 Btu/hr/ft per shelf row for fluorescent lamps.
DEFROST DATA
D5NX-LEP
Frequency Hr 8
Defrost Water (lb/ft/day) 10.50
(± 15% based on case configuration and product
loading).
OFFTIME D5NX-LEP
Time (Minutes) 30
ELECTRIC OR GAS Not Recommended
CONVENTIONAL CONTROLS
Low Pressure Backup Control
CI/CO* D5NX-LEP
19°F / 9°F
Indoor Unit Only, Pressure Defrost
Termination* 48°F
*Use a Temperature Pressure Chart to determine
PSIG conversions.
Estimated Charge ** D5NX-LEP
4 ft 1.6 lb 26 oz 0.7 kg
6 ft 2.3 lb 37 oz 1.0 kg
8 ft 3.2 lb 51 oz 1.5 kg
12 ft 4.5 lb 72 oz 2.0 kg
**This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound.
3 of 9
P/N 0480684_I
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
26 3/4 (680)
25 1/4 (641)
37 (940)
28 1/2 (724)
25 3/8
(644)
61
(1549)
34 5/8
(878)
FAN
C O
I
L
17 1/4
(438)
3 In. (77 mm)
Required
Air Gap
7 1/4 (183)
19 5/8
(499)
3 5/8
(92)
21 1/4 (540)
Refrigeration
Outlet
6
(152)
54 7/8
(1393)
4 3/4 (120)
Electrical
Case to Case
Connections
12 1/4
(311)
81 3/4
(2077)
Impact
Excel
D5NX-LEP
Dairy & Delicatessen
Dimensions shown as in. and (mm).
Multi-deck, 5 Display Levels, Low Front, Narrow Footprint
D5NX-LEP
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.
Loading...
+ 6 hidden pages