Hussmann D5NLE Datasheet

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
D
D
E
B
E
A
C
E
P/N 0397284B
®
Note: Changed items have been underlined.
FAN ASSEMBLIES AND THERMOSTATS
A. 9W Fan Assembly (1)
0047000 Fan Motor, Evaporator 0315470 Fan Blade
embossing toward motor
B. 0411744 Standard Non-adjustable (2)
Defrost Thermostat
C. 0137880 Optional Adjustable (3)
Refrigeration Thermostat
Item Part # Description Wiring Item #
LAMPS AND BALLASTS
D. 0376409 Ballast, Electronic
2 lamps (4)
D. 0376410 Ballast, Electronic
3 lamps (4)
E. Fluorescent Lamp (5)
Replace with like fixtures
D5NLE
Data Sheet Set
P/N 0397284B
NSF
®
Certified
May, 2003
Merchandisers
2 of 6 D5NLE Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Engineering
Plan Views
Dimensions shown as in. and (mm).
Narrow Dairy &
Delicatessen
8 ft 12 ft
General
(A) Case Length (without ends or partitions) 96
3
/8
(2448) 144
1
/2
(3670)
Maximum O/S dimension of case back to front
(includes bumper) 40
5
/8 (1030) 40 5/8 (1030) Back of case to front of splashguard 33 (840) 33 (840) Back of case to O/S edge of front skid rail 25
1
/2 (648) 25 1/2 (648)
Width of skid rail 4
1
/
2 (114) 4
1
/
2 (114)
RH end of case to outside edge of external support 5
1
/
2 (140) 5
1
/
2 (140)
Distance between edges of external support and center support 40
5
/
8 (1032) 40
5
/
8 (1032)
Distance between edges of center supports NA 44 (1118) Stub-up area between front skid rail and splashguard 5
5
/8 (143) 55/8 (143)
Electrical Service (Electrical Field Wiring connection point)
(B) RH End of case to center of farthest knockout 88 3/8 (2245) 136 1/2 (3467)
Back of case to center of knockout 29
1
/8 (739) 29 1/8 (739)
Length of electrical raceway 34
5
/8 (878) 34 5/8 (878)
Waste Outlet
(C) RH End of case to the center of waste outlet 24 1/8 (613) 72 1/4 (1835)
LH End of case to the center of waste outlet 72
1
/4 (1835) 72 1/4 (1835)
Back O/S of case to center of waste outlet 27 (686) 27 (686)
Water Seal
Edge of water seal to center of waste outlet 4 (102) 4 (102) Outside diameter of the drip pipe 1
1
/2 (38) 1 1/2 (38)
NOTE:Water seal outlet must clear front skid rail; water seal rotation in forward direction only due to low base.
Refrigeration Outlet
Back of case to center of refrigeration outlet 27
1
/2 (699) 27 1/2 (699)
(D) RH end of case to center of refrigeration outlet 9 (230) 9 (230)
04-2003
Electrical
29
(739)
1
/8
5
40
/8
(1032)
A
/4 (1835)
Waste Outlet
Water Seal
(see note)
Front
4
B
1
40
/2 (105)
5
(1030)
27
(688)
/8
5
(143)
1
72
5
/8
27
(699)
4 (102)
C
1
/2
D
Refrigeration
4
5
1
1
/2 (114)
1
/2 (140)
3
/8 (035)
25
1
(648)
/2
1
33
/8
(841)
40
(1030)
5
/8
Loading...