Hussmann D5LR Datasheet

Page 1
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
D
D
E
B
E
A
C
E
P/N 0381957C
®
Note: Changed items have been underlined.
FAN ASSEMBLIES AND THERMOSTATS
A. 9W Fan Assembly (1)
0047000 Fan Motor, Evaporator 0435961 Fan Blade
embossing toward motor
B. 0411744 Standard Non-adjustable (2)
Defrost Thermostat
C. 0137880 Optional Adjustable (3)
Refrigeration Thermostat
Item Part # Description Wiring Item #
LAMPS AND BALLASTS
D. 0376409 Ballast, Electronic
2 lamps (4)
D. 0376410 Ballast, Electronic
3 lamps (4)
D. 0376411 Ballast, Electronic
4 lamps (4)
E. Fluorescent Lamp (5)
Replace with like fixtures
D5LR
Data Sheet Set
P/N 0381957C
NSF
®
Certified
May, 2003
Merchandisers
Page 2
2 of 8
D5LR Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Engineering
Plan Views
Dimensions shown as in. and (mm).
Dairy & Delicatessen
8 ft 12 ft
General
(A) Case Length (without ends or partitions) 96 3/
8 (2448) 144
1
/
2 (3670)
Maximum O/S dimension of case back to front
(includes bumper) 46
1
/4 (1174) 46 1/4 (1174)
Back of case to front of splashguard 38
5
/8 (981) 38 5/8 (981)
Back of case to O/S edge of front skid rail 29
1
/2 (749) 29 1/2 (749)
Width of skid rail 4
1
/2
(114) 4
1
/2
(114)
RH end of case to outside edge of external support 5
1
/
2 (140) 5
1
/
2 (140)
Distance between edges of external support and center support 40
5
/8
(1032) 40
5
/8
(1032) Distance between edges of center supports NA 44 (1118) Stub-up area between front skid rail and splashguard 7 (178) 7 (178)
Electrical Service (Electrical Field Wiring connection point)
(B) RH End of case to center of farthest knockout 88
3
/8 (2245) 136 1/2 (3467)
Back of case to center of knockout 35
3
/8 (899) 35 3/8 (899)
Length of electrical raceway 34
5
/8 (878) 34 5/8 (878)
Waste Outlet
(C) RH End of case to the center of waste outlet 24
1
/8 (613) 72 1/4 (1835)
LH End of case to the center of waste outlet 72
1
/
4 (1835) 72
1
/
4 (1835)
Back O/S of case to center of waste outlet 27
1
/2 (699) 27 1/2 (699)
Water Seal
Edge of water seal to center of waste outlet 4 (102) 4 (102) Outside diameter of the drip pipe 1
1
/2 (38) 1 1/2 (38)
NOTE:Water seal outlet must clear front skid rail; water seal rotation in forward direction only due to low base.
Refrigeration Outlet
Back of case to center of refrigeration outlet 30
5
/8 (778) 30 5/8 (778)
(D) RH end of case to center of refrigeration outlet 9 (230) 9 (230)
05-2003
(899)
A
40 5/8
(1032)
7 (178)
72 1/4
(1835)
Waste Outlet
Front
B
4 1/4 (108)
27 1/2
(699)
Water Seal
(See note)
40 5/8
(1032)
Refrigeration
Outlet
30 5/8
(778)
4 (102)
C
41/2 (114)
D
35 3/8
Electrical
51/2 (140) 13/8 (35)
29 1/2
(749)
38 5/8
(981)
46 1/4
(1174)
Page 3
3 of 8
P/N 0381957C
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
COIL
D5LR
FAN
7
1
/2
(152)
45 5/8
(1159)
3 1/8
(79)
81 3/8
(2066)
53 5/8
(1360
5 3/4
(146)
4 1/2
(114)
27 1/2 (699)
29 1/2 (749)
38 5/8 (981)
46 1/4 (1174)
4 (102)
7
(178)
4 1/4
(108)
19
(483)
2 3/4 (70)
30 1/8
(765)
56 1/4
(1429)
61
(1549)
Impact D5LR
Dairy & Delicatessen
Dimensions shown as in. and (mm).
NOTE: The bumpers are 4 in. (102 mm) wide. The center of the top
bumper is 14
1
/
8
in. (359 mm) from the floor and the center of
the lower bumper is 6 1/8 in. (155 mm) from the floor.
Multi-deck, 5 Display Levels with Sliding Rear Door
NSF Certification
These merchandisers are manufactured to meet ANSI /National Sanitation Foundation (NSF
®
) Standard #7 requirements.
REFRIGERATION DATA
Note: This data is based on store temperature
and humidity that does not exceed 75°F and 55% R.H.
D5LR D5LRE
Discharge Air °F 31 32 Evaporator °F 21 24 Unit Sizing °F 19 22
Btu/hr/ft* D5LR D5LRE
L
IT &U
NLIT SHELVES
Parallel 1645 1570 Conventional 1740 1670
H
USSMANN PEG SHELVES (DELI ONLY)
Parallel 1765 1690 Conventional 1860 1790
*For all refrigeration equipment other than Hussmann, use conventional Btu values.
DEFROST DATA
Frequency Hrs 66 Defrost Water (lb/ft/day) 10.50
(± 15% based on case configuration and
product loading).
O
FFTIME
D5LR D5LRE
Temp Term °F 48 48 Failsafe Minutes 30 35
ELECTRIC OR GAS Not Recommended
Standard Defrost Thermostat
Close on rise: close 48°F — open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control CI/CO** D5LR D5LRE
14°F / 4°F 17°F / 7°F
Indoor Unit Only, Pressure Defrost Termination** 48°F
**Use a Temperature Pressure Chart to determine PSIG conversions.
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/2 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
7
/8
Estimated Charge (lb)***
D5LR D5LRE
8 ft 2.3 2.7 12 ft 3.3 3.9
***This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound.
Length Added to Lineup by
Each End (in.) 1
1
/2
Each Insulated Partition (in.) 1 1/2
Page 4
4 of 8
D5LR Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Impact D5LR
Dairy & Delicatessen
Electrical Data
Number of Fans 8 ft 12 ft Refrigeration – 9W 4 6 Export – 9W 4 6
Amperes Watts Merchandiser 8 ft 12 ft 8 ft 12 ft Fans (Refrigeration)
Standard (120V 60Hz) 2.80 4.20 210 320 Energy Efficient (120V 60Hz) 1.52 2.28 100 150 Export (230V 50Hz) 1.52 2.28 228 342
Constant On Anti-sweat Heaters NA NA NA NA
Cycling Anti-sweat Heaters NA NA NA NA
Minimum Circuit Ampacity
With Standard Fans (120V 60Hz) 3.00 4.40 With Energy Efficient Fans (120V 60Hz) 1.72 2.48 With Export Fans (230V 50Hz) 1.72 2.48
Maximum Over Current Protection 120V 20 20
Export (230V 50Hz) 15 15
Electric Defrost Heaters (208V 1
ΦΦ
) NA NA NA NA
Gas Defrost Heaters (208V) NA NA NA NA
Standard Lighting 8 ft 12 ft 8 ft 12 ft
1 Row Canopy 0.51 0.77 59 85
Optional Lighting
1 Row Canopy and 1 Row Rail 1.02 1.54 118 170 2 Rows Canopy 1.02 1.54 118 170 2 Rows Canopy and 1 Row Rail 1.53 2.31 177 255 3 Rows Canopy 1.53 2.31 177 255 3 Rows Canopy and 1 Row Rail 2.04 3.08 236 340
Optional Shelf Lighting
4 Rows of Shelves 1.84 2.76 224 336
NOTE: 8 foot merchandiser has two columns of four rows of lighted shelves and
12 foot merchandiser has three columns of four rows of lighted shelves.
Page 5
5 of 8P/N 0381957C
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
4 & 6 Fans
120V POWER
ROWN BAND
B
Fans
Fan Wiring
Offtime Defrost
120V NEUTRAL
ROWN BAND
1
B
Optional Shelf Harness and Light Circuits for One Column of Four Lighted Shelves
Note: 8 Foot merchandiser has two columns of four shelves and
12 Foot merchandiser has three columns of four shelves.
W
G
B
4
Shelf Harness
G
Y
R
Y
G
BL
G
R
G
Y
Y
BL
W
G
B
Defrost
Termination
Thermostat
Dark Blue
BL
Y
G
Refrigeration
2
Thermostat
Light Blue
3
To Condensing Unit
}
Rear Door Dairy
Shelf Lighting
Y
G
BL
Shelf Light Circuits
BL
Connector
G
R
5
BL
Connector
G
Connector
R
5
G
BL
R
5
Connector
G
BL
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
Grayed components in 12 foot models only.
R = Red Y = Yellow G = Green BL = Blue B = Black W = White
= 120V P
OWER = 120V NEUTRAL = FIELD GROUND
= CASE GROUND
R
5
Page 6
6 of 8
D5LR Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Light Circuits
Standard Lighting 1 Row Canopy or Optional 1 Row Rail
120V NEUTRAL
ORANGE OR TAN BAND
120V POWER
ORANGE OR TAN BAND
Light
Switch
W
B
4
Optional Lighting 2 Rows Canopy
120V NEUTRAL
ORANGE OR TAN BAND
120V POWER
ORANGE OR TAN BAND
Light
Switch
B
W
4
W
B
4
Optional Lighting 3 Row Canopy
120V NEUTRAL
ORANGE OR TAN BAND
120V POWER
ORANGE OR TAN BAND
Light
Switch
W
B
B
B
4
W
4
W
4
BL
R
BL
55
BL
R
BL
5
BL
R
BL
BL
R
BL
5
BL
R
BL
R
BL
BL
55
BL
R
BL
R
5
BL
R
55
BL
R
5
BL
R
55
BL
R
R
5
R
5
R
5
R
5
R
5
R
5
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
IRCLED NUMBERS = PARTS LIST ITEM NUMBERS
C
Grayed components in 12 foot models only.
R = Red Y = Yellow G = Green BL = Blue B = Black W = White
= 120V POWER
= 120V NEUTRAL
Page 7
7 of 8P/N 0381957C
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
23 3/
Impact D5LR
Dairy & Delicatessen
84 1/
4
37 3/
4
67 1/
4
2
Doors
Fully Closed
Doors
Fully Opened
Rear Coil Grills
Rear View of 8 Foot Dairy Merchandiser
Double-walled telescoping doors slide both left and right.
NOTE: Consult Cooler Close-off Kit for instructions on connecting the merchandiser to the cooler.
79 1/
2
Page 8
D5LR Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
8 of 8
Impact
D5LR
Dairy & Delicatessen
/
3
23
4
1
2
/ 67
2
/
1
79
Fully Opened
Doors
Rear Coil Grill
4
/
1
130
/
3
37
4
NOTE: Consult Cooler Close-off Kit for Instructions on
connecting the merchandiser to the cooler.
Fully Closed
Doors
4
/
3
Rear Coil Grill
Rear View of 12 Foot Dairy Merchandiser
Double-walled telescoping doors slide both left and right.
23
Fully Opened
Doors
Rear Coil Grill