HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
®
Note: Changed items have been underlined.
Item Part # Description Wiring Item #
F
AN ASSEMBLIES AND THERMOSTATS
A. 9W Fan Assembly (1)
0047000 Fan Motor, Evaporator
0380485 Fan Blade
embossing toward motor
B. 0137880 Optional Adjustable (3)
Refrigeration Thermostat
Item Part # Description Wiring Item #
L
AMPS AND BALLASTS
C. 0376409 Ballast, Electronic
2 lamps (4)
C. 0376410 Ballast, Electronic
3 lamps (4)
D. Fluorescent Lamp (5)
Replace with like fixtures
D6LEPLUS
Data Sheet Set
P/N 0473261
NSF
®
Certified
May 2005
Merchandisers

2 of 6 D6LEPLUS Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Engineering
Plan Views
Dimensions shown as in. and (mm).
Narrow Dairy &
Delicatessen
8 ft 12 ft
General
(A) Case Length (without ends or partitions) 96
3
/
8 (2448) 144
1
/
2 (3670)
Maximum O/S dimension of case back to front
(includes bumper) 40
5
/8 (1030) 40 5/8 (1030)
Back of case to front of splashguard 33 (840) 33 (840)
Back of case to O/S edge of front skid rail 25
1
/2 (648) 25 1/2 (648)
Width of skid rail 4
1
/2 (114) 4 1/2 (114)
RH end of case to outside edge of external support 5
1
/2 (140) 5 1/2 (140)
Distance between edges of external support and center support 40
5
/8 (1032) 40 5/8 (1032)
Distance between edges of center supports NA 44 (1118)
Stub-up area between front skid rail and splashguard 5
5
/8
(143) 5
5
/8
(143)
Electrical Service (Electrical Field Wiring connection point)
(B) RH End of case to center of farthest knockout 88
3
/8 (2245) 136 1/2 (3467)
Back of case to center of knockout 29
1
/8 (739) 29 1/8 (739)
Length of electrical raceway 34
5
/8 (878) 34 5/8 (878)
Waste Outlet
(C) RH End of case to the center of waste outlet 24
1
/8 (613) 72 1/4 (1835)
LH End of case to the center of waste outlet 72 1/4 (1835) 72 1/4 (1835)
Back O/S of case to center of waste outlet 27 (686) 27 (686)
WaterSeal
Edge of water seal to center of waste outlet 4 (102) 4 (102)
Outside diameter of the drip pipe 1
1
/2 (38) 1 1/2 (38)
NOTE: Water seal outlet must clear front skid rail;
water seal rotation in forward direction only due to low base.
Refrigeration Outlet
Back of case to center of refrigeration outlet 27
1
/
2 (699) 27
1
/
2 (699)
(D) RH end of case to center of refrigeration outlet 9 (230) 9 (230)
04-2003
1
29
/8
(739)
5
40
/8
(1032)
Electrical
5
5
(143)
A
/4 (1835)
Waste Outlet
Water Seal
(see note)
Front
B
4
1
/2 (105)
40
(1030)
C
1
27
27
(688)
5
/8
(699)
4 (102)
/2
D
Refrigeration
4
5
1
1
/2 (114)
1
/2 (140)
3
/8 (035)
25
1
72
/8
(648)
1
/2
33
(841)
1
/8
40
(1030)
5
/8

62 7/8
(1597)
38 1/8
(969)
5 3/8
(136)
3 1/
8
(79)
7 1/2
(152)
24 1/2
(623)
4 1/4
(108)
41/2
(114)
4 (102)
27
(686)
25 1/2 (646)
33
(840)
66 5/8
(1693)
49 3/8
(1259)
87
(2209)
40 5/8 (1030)
2 3/8 (60)
19
(483)
C
O
I
L
FAN
D6LEPLUS
5 5/8
(144)
6 1/8
(155)
14 1/8
(359)
Multi-deck, 6 Display Levels
Dimensions shown as in. and (mm).
Impact D6LEPLUS
Dairy & Delicatessen
REFRIGERATION DATA
Note: This data is based on store temperature
and humidity that does not exceed 75°F and
55% R.H.
D6LEPLUS
Lit Unlit
Discharge Air °F 31 33
Evaporator °F 26 28
Unit Sizing °F 24 26
Btu/hr/ft* D6LEP
LUS
Lit Unlit
Parallel 1625 1545
Conventional 1690 1610
*For all refrigeration equipment other than
Hussmann, use conventional Btu values.
DEFROST DATA
Frequency Hrs 12
Defrost Water (lb/ft/day) 10.5
(± 15% based on case configuration and
product loading).
OFFTIME D6LEPLUS
Time (minutes) 30
ELECTRIC OR GAS Not Recommended
Standard Defrost Thermostat NA
CONVENTIONAL CONTROLS
Low Pressure Backup Control
CI/CO** D6LEP
Indoor Unit Only, Pressure Defrost
Termination** 48°F
**Use a Temperature Pressure Chart to
determine PSIG conversions.
LUS
17°F / 7° F
NSF Certification
These merchandisers are manufactured to meet ANSI / National Sanitation
®
Foundation (NSF
) Standard #7 requirements.
P/N 0473261
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/2
Merchandiser Liquid Line (in.)
Merchandiser Suction Line (in.)
Estimated Charge (lb)***
8 ft 3.7
12 ft 5.1
***This is an average for all refrigerant types.
Actual refrigerant charge may vary by
approximately half a pound.
Length Added to Lineup by
Each End (in.) 1
Each Insulated Partition (in.) 1 1/2
D6LEP
3
/8
7
/8
LUS
1
/2
3 of 6

4 of 6 D6LEPLUS Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Impact D6LEP
LUS
Dairy & Delicatessen
Electrical Data
Number of Fans 8 ft 12 ft
Refrigeration – 9W 4 6
Export – 9W 4 6
Amperes Watts
Merchandiser 8 ft 12 ft 8 ft 12 ft
Fans (Refrigeration)
Standard (120V 60Hz) 2.80 4.20 210 320
Energy Efficient (120V 60Hz) 1.52 2.28 100 150
Export (230V 50Hz) 1.52 2.28 228 342
Constant On Anti-sweat Heaters NA NA NA NA
Cycling Anti-sweat Heaters NA NA NA NA
Minimum Circuit Ampacity
With Standard Fans (120V60Hz) 3.00 4.40
With Energy Efficient Fans (120V 60Hz) 1.72 2.48
With Export Fans (230V 50Hz) 1.72 2.48
Maximum Over Current Protection 120V 20 20
Export (230V 50Hz) 15 15
Electric Defrost Heaters (208V 1ΦΦ) NA NA NA NA
Gas Defrost Heaters (208V) NA NA NA NA
Standard Lighting 8 ft 12 ft 8 ft 12 ft
1 Row Canopy 0.51 0.77 59 85
Optional Lighting
1 Row Canopy and 1 Row Rail 1.02 1.54 118 170
2 Rows Canopy 1.02 1.54 118 170
2 Rows Canopy and 1 Row Rail 1.53 2.31 177 255
Optional Shelf Lighting
1 Row Shelves 0.51 0.77 59 85
2 Rows of Shelves 1.02 1.54 118 170
3 Rows of Shelves 1.53 2.31 177 255
4 Rows of Shelves 2.04 3.08 236 340
5 Rows of Shelves 2.55 3.85 295 425

5 of 6P/N 0473261
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
4 & 6 Fans
120V POWER
ROWN BAND
B
Fans
Fan Wiring
Offtime Defrost
120V NEUTRAL
B
1
ROWN BAND
Optional Shelf Harness and Light Circuits for
One Row of Shelves
Shelf Harness
Connector
W
B
120 V
Power
Connector
G
B
W
3
G
R
BL
BL
BL
W
G
B
G
R
G
R
BL
Refrigeration
Thermostat
Light Blue
2
To
Condensing
Unit
}
Shelf Lighting
Connector
G
BL
BL G
R
BL
R
G
R
BL
BL
Connector
Connector
G
R
4
Shelf Light Circuits
Connector
Connector Connector
G
BL
R
4
BL
Connector
G
R
4
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
Grayed components in 12 foot models only.
R = Red Y = Yellow G = Green BL = Blue B = Black W = White
= 120V P
OWER = 120V NEUTRAL = FIELD GROUND
= CASE GROUND

6 of 6 D6LEPLUS Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Light Circuits
Standard Lighting 1 Row Canopy or Optional 1 Row Rail
120V NEUTRAL
ORANGE OR TAN BAND
120V POWER
ORANGE OR TAN
BAND
Light
Switch
W
B
4
Optional Lighting 2 Rows Canopy
120V NEUTRAL
ORANGE OR TAN BAND
120V POWER
ORANGE OR TAN
BAND
Light
Switch
B
W
4
W
B
4
Optional Lighting 3 Row Canopy
120V NEUTRAL
ORANGE OR TAN BAND
120V POWER
ORANGE OR TAN
BAND
Light
Switch
W
B
B
4
W
4
W
R
BL
BL
BL
BL
55
R
R
BL
BL
BL
5
BL
R
R
BL
5
BL
BL
R
BL
R
5
BL
R
55
BL
R
5
BL
R
55
R
5
R
5
R
5
R
5
R
5
B
4
R
BL
BL
55
BL
R
R
5
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
IRCLED NUMBERS = PARTS LIST ITEM NUMBERS
C
Grayed components in 12 foot models only.
R = Red Y = Yellow G = Green BL = Blue B = Black W = White