Hussmann D5HR Datasheet

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
D
D
E
B
E
E
A
C
P/N 0381959C
®
Note: Changed items have been underlined.
Data Sheet Set
P/N 0381959C
NSF
®
Certified
May, 2003
Item Part # Description Wiring Item #
FAN ASSEMBLIES AND THERMOSTATS
A. 9W Fan Assembly (1)
0047000 Fan Motor, Evaporator 0435961 Fan Blade
embossing toward motor
B. 0411744 Standard Non-adjustable (2)
Defrost Thermostat
C. 0137880 Optional Adjustable (3)
Refrigeration Thermostat
Item Part # Description Wiring Item #
LAMPS AND BALLASTS
D. 0376409 Ballast, Electronic
2 lamps (4)
D. 0376410 Ballast, Electronic
3 lamps (4)
D. 0376411 Ballast, Electronic
4 lamps (4)
E. Fluorescent Lamp (5)
Replace with like fixtures
Merchandisers
2 of 8 D5HR Data Sheet Set
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Dimensions shown as in. and (mm).
Dairy & Delicatessen
05-2003
Engineering
Plan Views
8 ft 12 ft
General
(A) Case Length (without ends or partitions) 96 3/
8 (2448) 144
1
/
2 (3670)
Maximum O/S dimension of case back to front
(includes bumper) 46
1
/4 (1174) 46 1/4 (1174)
Back of case to front of splashguard 38
5
/8 (981) 38 5/8 (981)
Back of case to O/S edge of front skid rail 29
1
/2 (749) 29 1/2 (749)
Width of skid rail 4
1
/
2 (114) 4
1
/
2 (114)
RH end of case to outside edge of external support 5
1
/2
(140) 5
1
/2
(140)
Distance between edges of external support and center support 40
5
/
8 (1032) 40
5
/
8 (1032)
Distance between edges of center supports NA 44 (1118) Stub-up area between front skid rail and splashguard 7 (178) 7 (178)
Electrical Service (Electrical Field Wiring connection point)
(B) RH End of case to center of farthest knockout 88
3
/8 (2245) 136 1/2 (3467)
Back of case to center of knockout 35
3
/
8 (899) 35
3
/
8 (899)
Length of electrical raceway 34
5
/8 (878) 34 5/8 (878)
Waste Outlet
(C) RH End of case to the center of waste outlet 24
1
/8 (613) 72 1/4 (1835)
LH End of case to the center of waste outlet 72
1
/4 (1835) 72 1/4 (1835)
Back O/S of case to center of waste outlet 27
1
/2 (699) 27 1/2 (699)
Water Seal
Edge of water seal to center of waste outlet 4 (102) 4 (102) Outside diameter of the drip pipe 1
1
/2 (38) 1 1/2 (38)
NOTE:Water seal outlet must clear front skid rail; water seal rotation in forward direction only due to low base.
Refrigeration Outlet
Back of case to center of refrigeration outlet 30
5
/8 (778) 30 5/8 (778)
(D) RH end of case to center of refrigeration outlet 9 (230) 9 (230)
A
35 3/8
(899)
Electrical
72 1/4
(1835)
40 5/8
(1032)
7 (178)
B
4 1/4 (108)
27 1/2
(699)
Waste Outlet
Water Seal
(See note)
Front
40 5/8
(1032)
Refrigeration
Outlet
30 5/8
(778)
4 (102)
C
D
51/2 (140) 13/8 (35)
41/2 (114)
29 1/2
(749)
38 5/8
(981)
46 1/4
(1174)
3 of 8
P/N 0381959C
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
FAN
COIL
45
5
/8
(1159)
3 1/8
(79)
7 1/2
(152)
48 1/4
(1225)
61
(1549)
81 3/8
(2066)
53 5/8
(1360)
30 1/8
(765)
10 3/4 (273)
27
(686)
4 1/4
(108)
7
(178)
4 (102)
27 1/2 (699)
29 1/2 (749)
38 5/8 (981)
46 1/4 (1174)
5 3/4
(146)
4 1/2
(114)
D5HR
Dimensions shown as in. and (mm).
NOTE: The bumpers are 4 in. (102 mm) wide. The center of the top
bumper is 22
1
/8 in. (562 mm) from the floor and the center of
the lower bumper is 6
1
/
8 in. (155 mm) from the floor.
Multi-deck, 5 Display Levels and Sliding Rear Door
NSF Certification
These merchandisers are manufactured to meet ANSI /National Sanitation Foundation (NSF
®
) Standard #7 requirements.
REFRIGERATION DATA
Note: This data is based on store temperature
and humidity that does not exceed 75°F and 55% R.H.
D5HR D5HRE
Discharge Air °F 31 32 Evaporator °F 21 24 Unit Sizing °F 19 22
Btu/hr/ft* D5HR D5HRE
L
IT &UNLIT SHELVES
Parallel 1480 1425 Conventional 1580 1520
H
USSMANN
PEG SHELVES
(DELI ONLY
)
Parallel 1545 1500 Conventional 1640 1600
*For all refrigeration equipment other than Hussmann, use conventional Btu values.
DEFROST DATA
Frequency Hrs 66 Defrost Water (lb/ft/day) 10.50
(± 15% based on case configuration and
product loading).
O
FFTIME
D5HR D5HRE
Temp Term °F 48 48 Failsafe Minutes 30 35
E
LECTRIC OR GAS
Not Recommended
Standard Defrost Thermostat
Close on rise: close 48°F — open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control CI/CO** D5HR D5HRE
14°F / 4°F 17°F / 7°F
Indoor Unit Only, Pressure Defrost Termination** 48°F
**Use a Temperature Pressure Chart to determine PSIG conversions.
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/2 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
7
/8
Estimated Charge (lb)***
D5HR D5HRE
8 ft 2.3 2.7 12 ft 3.3 3.9
***This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound.
Length Added to Lineup by
Each End (in.) 1
1
/2
Each Insulated Partition (in.) 1 1/2
Impact D5HR
Dairy & Delicatessen
Loading...
+ 5 hidden pages