Hussmann D5H Datasheet

Page 1
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
D
D
E
B
E
A
C
E
P/N 0378429D
®
Note: Changed items have been underlined.
F
AN ASSEMBLIES AND THERMOSTATS
A. 9W Fan Assembly (1)
0047000 Fan Motor, Evaporator 0315470 Fan Blade
embossing toward motor
B. 0411744 Standard Non-adjustable (2)
Defrost Thermostat
C. 0137880 Optional Adjustable (3)
Refrigeration Thermostat
Item Part # Description Wiring Item #
LAMPS AND BALLASTS
D. 0376409 Ballast, Electronic
2 lamps (4)
D. 0376410 Ballast, Electronic
3 lamps (4)
E. Fluorescent Lamp (5)
Replace with like fixtures
D5H
Data Sheet Set
P/N 0378429D
NSF
®
Certified
May, 2003
Merchandisers
Page 2
2 of 6 D5H Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Engineering
Plan Views
Dimensions shown as in. and (mm).
Dairy & Delicatessen
8 ft 12 ft
General
(A) Case Length (without ends or partitions) 96
3
/
8 (2448) 144
1
/
2 (3670)
Maximum O/S dimension of case back to front
(includes bumper) 46
1
/4 (1174) 46 1/4 (1174)
Back of case to front of splashguard 38
5
/
8 (981) 38
5
/
8 (981)
Back of case to O/S edge of front skid rail 29
1
/
2 (749) 29
1
/
2 (749)
Width of skid rail 4
1
/
2 (114) 4
1
/
2 (114)
RH end of case to outside edge of external support 5
1
/
2 (140) 5
1
/
2 (140)
Distance between edges of external support and center support 40
5
/8 (1032) 40 5/8 (1032) Distance between edges of center supports NA 44 (1118) Stub-up area between front skid rail and splashguard 7 (178) 7 (178)
Electrical Service (Electrical Field Wiring connection point)
(B) RH End of case to center of farthest knockout 88 3/8 (2245) 136 1/2 (3467)
Back of case to center of knockout 35
3
/8 (899) 35 3/8 (899)
Length of electrical raceway 34
5
/8 (878) 34 5/8 (878)
Waste Outlet
(C) RH End of case to the center of waste outlet 24 1/8 (613) 72 1/4 (1835)
LH End of case to the center of waste outlet 72
1
/
4 (1835) 72
1
/
4 (1835)
Back O/S of case to center of waste outlet 27
1
/2 (699) 27 1/2 (699)
Water Seal
Edge of water seal to center of waste outlet 4 (102) 4 (102) Outside diameter of the drip pipe 1
1
/2 (38) 1 1/2 (38)
NOTE:Water seal outlet must clear front skid rail; water seal rotation in forward direction only due to low base.
Refrigeration Outlet
Back of case to center of refrigeration outlet 30
5
/8 (778) 30 5/8 (778)
(D) RH end of case to center of refrigeration outlet 9 (230) 9 (230)
05-2003
A
B
40 5/8
(1032)
7 (178)
72 1/4
(1835)
Waste Outlet
Front
4 1/4 (108)
27 1/2
(699)
Water Seal
(See note)
40 5/8
(1032)
Refrigeration
Outlet
35 3/8
(899)
Electrical
30 5/8
(778)
4 (102)
C
D
51/2 (140) 13/8 (35)
41/2 (114)
29 1/2
(749)
38 5/8
(981)
46 1/4
(1174)
Page 3
3 of 6
P/N 0378429D
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
C O
I
L
48
1
/4
(1429)
61
(1549)
81
3
/8
(2066)
45
5
/8
(1159)
D5H
FAN
5
3
/4
(146)
27
(686)
3
1
/8
(79)
7
1
/2
(152)
7
(178)
46 1/4 (1174)
27 1/2 (699)
30
1
/8
(765)
4
1
/4
(108)
29
1
/2
(749)
4
1
/2
(114)
38
5
/8
(981)
10
3
/4
(273)
53 5/8
(1360)
4 (102)
Impact
D5H
Dairy & Delicatessen
Dimensions shown as in. and (mm).
NOTE: The bumpers are 4 in. (102 mm) wide. The center of the top
bumper is 22
1
/8 in. (562 mm) from the floor and the center of
the lower bumper is 6
1
/8 in. (155 mm) from the floor.
Multi-deck, 5 Display Levels
NSF Certification
These merchandisers are manufactured to meet ANSI /National Sanitation Foundation (NSF
®
) Standard #7 requirements.
REFRIGERATION DATA
Note: This data is based on store temperature
and humidity that does not exceed 75°F and 55% R.H.
D5H D5HE
Discharge Air °F 31 32 Evaporator °F 21 24 Unit Sizing °F 19 22
Btu/hr/ft* D5H D5HE
L
IT &U
NLIT SHELVES
Parallel 1330 1280 Conventional 1420 1365
H
USSMANN PEG SHELVES (DELI ONLY)
Parallel 1450 1400 Conventional 1540 1485
*For all refrigeration equipment other than Hussmann, use conventional Btu values.
DEFROST DATA
Frequency Hrs 66 Defrost Water (lb/ft/day) 10.50
(± 15% based on case configuration and
product loading).
OFFTIME D5H D5HE Temp Term °F 48 48 Failsafe Minutes 35 35
E
LECTRIC OR
GAS
Not Recommended
Standard Defrost Thermostat
Close on rise: close 48°F — open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control CI/CO** D5H D5HE
14°F / 4°F 17°F / 7°F
Indoor Unit Only, Pressure Defrost Termination** 48°F
**Use a Temperature Pressure Chart to determine PSIG conversions.
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/2 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
7
/8
Estimated Charge (lb)***
D5H D5HE
8 ft 2.3 2.7 12 ft 3.3 3.9
***This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound.
Length Added to Lineup by
Each End (in.) 1
1
/2
Each Insulated Partition (in.) 1 1/2
Page 4
4 of 6 D5H Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Impact D5H
Dairy & Delicatessen
Electrical Data
Number of Fans 8 ft 12 ft Refrigeration – 9W 2 3 Export – 9W 2 3
Amperes Watts
Merchandiser 8 ft 12 ft 8 ft 12 ft
Fans (Refrigeration)
Standard (120V 60Hz) 1.40 2.10 105 160 Energy Efficient (120V 60Hz) 0.76 1.14 50 75 Export (230V 50Hz) 0.76 1.14 114 171
Constant On Anti-sweat Heaters NA NA NA NA
Cycling Anti-sweat Heaters NA NA NA NA
Minimum Circuit Ampacity
With Standard Fans (120V 60Hz) 1.60 2.30 With Energy Efficient Fans (120V 60Hz) 0.96 1.34 With Export Fan (230V 50Hz) 0.96 1.34
Maximum Over Current Protection 120V 20 20
Export (230V 50Hz) 15 15
Electric Defrost Heaters (208V 1
ΦΦ
) NA NA NA NA
Gas Defrost Heaters (208V) NA NA NA NA
Standard Lighting 8 ft 12 ft 8 ft 12 ft
1 Row Canopy 0.51 0.77 59 85
Optional Lighting
1 Row Canopy and 1 Row Rail 1.02 1.54 118 170 2 Rows Canopy 1.02 1.54 118 170 2 Rows Canopy and 1 Row Rail 1.53 2.31 177 255
Optional Shelf Lighting
1 Row Shelves 0.51 0.77 59 85 2 Rows of Shelves 1.02 1.54 118 170 3 Rows of Shelves 1.53 2.31 177 255 4 Rows of Shelves 2.04 3.08 236 340
Page 5
5 of 6P/N 0378429D
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
2 & 3 Fans
120V POWER
ROWN BAND
B
Fans
Fan Wiring
Offtime Defrost
120V NEUTRAL
B
1
ROWN BAND
Optional Shelf Harness and Light Circuits for One Row of Shelves
Shelf Harness
Connector
W
B
120 V Power
Connector
G
B
W
4
BL
R
BL
BL
W
G
G
G
R
BL
Connector
Defrost
Termination
Thermostat
Dark Blue
2
Refrigeration
Thermostat
Light Blue
3
To Condensing Unit
}
Shelf Lighting
B
G
BL
R
Connector
BL G
R
Connector
G
BL
R
G
R
BL
Connector
Shelf Light Circuits
BL
Connector
G
Connector
G G
R
5
BL
R
5
Connector
BL
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
Grayed components in 12 foot models only.
R = Red Y = Yellow G = Green BL = Blue B = Black W = White
= 120V P
OWER = 120V NEUTRAL = FIELD GROUND
= CASE GROUND
R
5
Page 6
6 of 6 D5H Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Light Circuits
Standard Lighting 1 Row Canopy or Optional 1 Row Rail
120V NEUTRAL
ORANGE OR TAN BAND
120V POWER
ORANGE OR TAN BAND
Light
Switch
W
B
4
Optional Lighting 2 Rows Canopy
120V NEUTRAL
ORANGE OR TAN BAND
120V POWER
ORANGE OR TAN BAND
Light
Switch
B
W
4
W
B
4
Optional Lighting 3 Row Canopy
120V NEUTRAL
ORANGE OR TAN BAND
120V POWER
ORANGE OR TAN BAND
Light
Switch
W
B
B
B
4
W
4
W
4
BL
R
BL
55
R
BL
R
BL
BL
BL
BL
BL
5
BL
R
R
R
BL
5
BL
BL
55
BL
R
BL
R
5
BL
R
55
BL
R
5
BL
R
55
BL
R
R
5
R
5
R
5
R
5
R
5
R
5
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
IRCLED NUMBERS = PARTS LIST ITEM NUMBERS
C
Grayed components in 12 foot models only.
R = Red Y = Yellow G = Green BL = Blue B = Black W = White
= 120V POWER
= 120V NEUTRAL