Hussmann D5EE, D5ELE Datasheet

Page 1
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
C
D
E
F
A
B
®
Item Part # Description Wiring Item #
FAN ASSEMBLIES AND THERMOSTATS
A. 9W Fan Assembly (1)
0047000 Fan Motor, Evaporator 0315470 Fan Blade
embossing toward motor
B. 0404551 Fan,Ambient (2)
C. 0411744 Standard Non-adjustable (3)
Defrost Thermostat
D. 0137880 Optional Adjustable (4)
Refrigeration Thermostat
Item Part # Description Wiring Item #
L
AMPS AND BALLASTS
E. 0376409 Ballast, Electronic, 2 lamps (5)
F. Fluorescent Lamp (6)
Replace with like fixtures
D5ELE / D5EE
Data Sheet Set
P/N 0407200A
NSF
®
Certified
May, 2003
Merchandisers
P/N 0407200A.
Page 2
2 of 6 D5ELE / D5EE Data Sheet Set
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Engineering
Plan Views
Multi-deck Dairy &
Delicatessen
End Case
D5EE / D5ELE
General
Case Length . . . . . . . . . . . . . . . . 93
5
/
8 (2378)
Maximum O/S dimension of case
back to front
(includes bumper) . . .46
1
/2 (1181)
Back of case to
front of splashguard . . . . . . . . . 37
3
/4 (959)
Back of case to O/S edge of
front base rail . . . . . . . . . . . . . 28
1
/2 (724)
Width of base rail . . . . . . . . . . . . . 2
1
/
8 (54)
Front of splashguard to O/S
edge of front base rail . . . . . . . . 8
1
/
2 (216)
Stub-up area between front
base rail and splashguard . . . . . 7
5
/
8 (194)
Electrical Service
(Electrical Field Wiring connection point)
LH End of case to
center of first knockout . . . . . . . 6
3
/4 (171)
Back O/S edge of case
to nearest knockout . . . . . . . . . 33
1
/2 (851)
Length of electrical raceway . . . . 35
5
/
8 (903)
Waste Outlet
Back O/S of case to
center of waste outlet . . . . . . . 26
3
/8 (670)
LH End of case to center of
waste outlet . . . . . . . . . . . . . . . . . . 51 (1295)
Water Seal
Edge of water seal to center of
waste outlet . . . . . . . . . . . . . . . . . . 11 (279)
Outside diameter of the drip pipe . 1
1
/2
(38)
Refrigeration Outlet
Back of case to center of
refrigeration outlet . . . . . . . . . 31
5
/8 (803)
LH end of case to center of
refrigeration outlet . . . . . . . . . 70
9
/16 (1792)
Dimensions shown as in. and (mm).
D5ELE
D5EE
04-2003
28
(714
1
33
/2
(851
)
81 1/4
(2062)
84 3/8
(2142)
19
(483)
Front View
5
93
/8
(2378
)
78
(1981)
39
(991)
C
51
(1295)
1
/8
)
Electrical
Waste Outlet
L
1
31
(802)
Refrigeration Outlet
Access Area
(Gray
)
/2
26 3/8
(670
29
)
(746
3
/8
)
45
(1153)
46 1/2
(1182)
3
/8
Front
Page 3
3 of 6
P/N 0407200A
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
C
O
I
L
D5ELE
D5EE
FAN
46 1/2 (1181)
47 1/2
(1207)
61/8
(201)
37 3/4 (959)
Refrigeration Outlet
29 1/2
(749)
31 5/
8
(803)
26 1/2 (672)
7 5/8
(194)
33 1/2
(851)
19
(483)
7 1/2 (191)
81 1/8
(2062)
56 1/4
(1429)
61
(1549)
5 1/2
(139)
30 3/8
(772)
22
(559)
Lighted Shelf
(Optional)
84 3/8
(2142)
Impact
D5ELE / D5EE
Dairy & Delicatessen
Dimensions shown as in. and (mm).
NOTE: The bumpers are 4 in. (102 mm) wide. The center of the top bumper is
14
1
/4 in. (368 mm) from the floor and the center of the lower bumper
is 6
1
/8 in. (155 mm) from the floor.
Multi-deck, 5 Display Levels
NSF Certification
These merchandisers are manufactured to meet ANSI /National Sanitation Foundation (NSF
®
) Standard #7 requirements.
REFRIGERATION DATA
Note: This data is based on store temperature
and humidity that does not exceed 75°F and 55% R.H.
D5ELE D5EE
Discharge Air (°F) 32 32 Evaporator (°F) 24 24 Unit Sizing (°F) 22 22 Btu/hr/case* D5ELE D5EE
Parallel
10,700 10,170
Conventional
11,400 10,830
*For all refrigeration equipment other than Hussmann, use conventional Btu values.
DEFROST DATA
D5ELE D5EE
Frequency (hr) 66 Defrost Water (lb/ft/day) 10.5 10.5
(± 15% based on case configuration and
product loading).
O
FFTIME
D5ELE D5EE
Temp Term (°F) 48° 48° Failsafe (minutes) 35 35
G
AS OR ELECTRIC Not Recommended
Standard Defrost Thermostat
Close on rise: close 48°F — open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control
D5ELE D5EE
CI/CO (Temp °F)** 17°/ 7° 17°/ 7°
Indoor Unit Only, Pressure Defrost Termination (Temp °F)**
Not Recommended
**Use a Temperature Pressure Chart to determine PSIG conversions.
PHYSICAL DATA
Drip Pipe (in.) 1 1/2 Liquid Line (in.) 3/8 Suction Line (in.) 7/8
Estimated Charge (lb)*** D5ELE 2.4 D5EE 2.4
***This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound.
Length Added to Lineup by: Each End/Partition (in.) 1 1/2
Page 4
Impact
D5ELE / D5EE
Dairy & Delicatessen
Electrical Data
Number of Fans D5ELE D5EE Refrigeration – 9W 2 2 Ambient Air Wipe – 15W 1 1 Export – 9W 2 2
Amperes Watts Merchandiser D5ELE D5EE D5ELE D5EE Fans (Refrigeration)
Standard (120V 60Hz) 1.40 1.40 110 110 Energy Efficient (120V 60Hz) 0.76 0.76 50 50 Export (230V 50Hz) 0.76 0.76 114 114
Fans (Ambient Air Wipe)
Standard (120V 60Hz) 0.25 0.25 22 22 Energy Efficient (120V 60Hz) NA NA NA NA Export (230V 50Hz) 0.15 0.15 25 25
Constant On Anti-sweat Heaters NA NA NA NA
Cycling Anti-sweat Heaters NA NA NA NA
Minimum Circuit Ampacity
With Standard Fans (120V 60Hz) 1.60 1.60 With Energy Efficient Fans (120V 60Hz) 0.96 0.96 With Export Fans (230V 50Hz) 0.47 0.47
Maximum Over Circuit Protection
Standard 120V 20 20
Export (230V 50Hz) 15 15
Electric Defrost Heaters (208V 1
Standard Lighting
1 Row Canopy 0.51 0.51 59 59
Optional Lighting
1 Row Canopy and 1 Row Rail 1.02 1.02 118 118 2 Rows Canopy 1.02 1.02 118 118 2 Rows Canopy and 1 Row Rail 1.53 1.53 177 177
Optional Shelf Lighting
1 Row of Shelves 0.51 0.51 59 59 2 Rows of Shelves 1.02 1.02 118 118 3 Rows of Shelves 1.53 1.53 177 177 4 Rows of Shelves 2.04 2.04 236 236
ΦΦ
) NA NA NA NA
4 of 6 D5ELE / D5EE Data Sheet Set
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Page 5
5 of 6P/N 0407200A
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
2 Fans
120V POWER
BROWN BAND
Fans
Fan Wiring
Offtime Defrost
120V NEUTRAL
B
1
2
ROWN BAND
Optional Shelf Harness and Light Circuits for One Row of Shelves
Shelf Harness
Connector
W
B
120 V
Power
Connector
G
B
W
5
G
R
BL
BL
R
W
G
BL
Connector
Defrost
Termination
Thermostat
Dark Blue
3
Refrigeration
Thermostat
Light Blue
4
To Condensing
}
Unit
Shelf Lighting
G
B
G
R
Connector
BL
BL G
R
Connector
BL
Connector
G
R
6
Shelf Light Circuits
BL
Connector
G
R
6
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
Grayed components in 12 foot models only.
R = Red Y = Yellow G = Green BL = Blue B = Black W = White
= 120V P
OWER = 120V NEUTRAL = Field GROUND = Case GROUND
Page 6
6 of 6 D5ELE / D5EE Data Sheet Set
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Lig ht Circ uits
Standard Lighting 1 Ro w Canopy o r Optio nal 1 Ro w Rail
120V NEUTRAL
ORANGE OR TAN BAND
120V POWER
ORANGE OR TAN BAND
Light
Switch
W
B
5
Optio nal Lighting 2 Ro ws Canopy
120V NEUTRAL
ORANGE OR TAN BAND
120V POWER
ORANGE OR TAN BAND
Light
Switch
B
W
5
W
B
5
R
BL
BL
BL
BL
6
R
R
BL
6
BL
6
R
6
R
6
R
6
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
Grayed components in 12 foot models only.
R = Red Y = Yellow G = Green BL = Blue B = Black W = White
= 120V P
OWER = 120V NEUTRAL = Field GROUND = Case GROUND
Loading...