Hussmann CW2-XGE Datasheet

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
E
D
B
C
A
P/N 0399331B
®
Note: Changed items have been underlined.
F
AN ASSEMBLIES AND THERMOSTATS
A. 6W Fan Assembly (1)
0058698 Fan Motor, Evaporator 0142780 Fan Blade
embossing toward motor
B. 0398558 Standard Non-adjustable (2)
Defrost Thermostat
C. 0144732 Optional Adjustable (3)
Refrigeration Thermostat
Item Part # Description Wiring Item #
L
AMPS AND BALLASTS
D. 0428648 Ballast, Electronic
2 lamps (4)
D. 0428649 Ballast, Electronic
3 lamps (4)
E. Fluorescent Lamp (5)
Replace with like fixtures
CW2-XGE
Data Sheet Set
P/N 0399331B
NSF
®
Certified
February 2005
Merchandisers
2 of 6 CW2XGE Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Engineering
Plan Views
Dimensions shown as inches and (mm).
Convertible Island
4 ft 8 ft 12 ft
General
(A) Case Length (without ends or partitions) 48 1/
4 (1226) 96
3
/
8 (2448) 144
1
/
2 (3670)
Maximum O/S dimension of case back to front
(includes bumper) 81
1
/2 (2070) 81 1/2 (2070) 81 1/2 (2070)
Front of splashguard to O/S edge of front base rail 8
1
/2 (216) 8 1/2 (216) 8 1/2 (216)
Front of case to O/S edge of front base rail 12
5
/8 (321) 12 5/8 (321) 12 5/8 (321)
Back of case to O/S edge of front base rail 68
7
/8 (1749) 68 7/8 (1749) 68 7/8 (1749)
Width of base rail 2
1
/8 (54) 2 1/8 (54) 2 1/8 (54)
Stub-up area between front base rail and splashguard 7
1
/4 (184) 7 1/4 (184) 7 1/4 (184)
Electrical Service
Note: Electrical Field Wiring connection point
Center of Electrical service to O/S edge of front base rail 7 (178) 7 (178) 7 (178) Right end of case to center of knockout 5 (127) 5 (127) 5 (127) Length of electrical raceway 46
5
/8 (1184) 46 5/8 (1184) 46 5/8 (1184)
Waste Outlet
(B) LH End of case to the center of waste outlet 10
1
/8 (257) 38 1/8 (968) 76 5/8 (1945)
Center of waste outlet to outside of front base rail 3
7
/8 (98) 3 7/8 (98) 3 7/8 (98)
Water Seal
Edge of water seal to center of waste outlet 4 (102) 4 (102) 4 (102)
(C) RH end of case to center of rear waste outlet 10
1
/8 (257) 38 1/8 (968) 76 5/8 (1946)
Outside diameter of the drip pipe 1
1
/4
(32) 1
1
/4
(32) 1
1
/4
(32)
Water seal outlet must clear front skid rail.
Refrigeration Outlet
Center of refrigeration outlet to O/S edge of front base rail 1
3
/8 (35) 1 3/8 (35) 1 3/8 (35)
RH end of case to center of refrigeration outlet 5
5
/8 (141) 5 5/8 (141) 5 5/8 (141)
05-2003
A
Base Rail
C
L
B
Waste Outlet & Water Seal
Access Area
8 1/2
(216)
Front
5 (127)
Refrigeration Outlet
(See Note)
C
CW2XGE
1
/2
5
(142)
81 1/2
(2070)
68 7/8
(1749)
(35)
3 7/8
(98)
7
(178)
1 3/8
12 5/8
(321)
REFRIGERATION DATA
Note: This data is based on store temperature
and humidity that does not exceed 75°F and 55% R.H.
CW2XGE Discharge Air (°F) 28 Evaporator (°F) 21 Unit Sizing (°F) 19
Btu/hr/ft* CW2XGE Parallel 1830 Conventional 2050
*For all refrigeration equipment other than Hussmann, use conventional Btu values.
DEFROST DATA
CW2XGE Frequency (hr) 6 Defrost Water (lb/ft/day) 12
(± 15% based on case configuration and
product loading).
OFFTIME CW2XGE
Temp Term (°F) 48°F Failsafe (minutes) 45
ELECTRIC OR GAS Not Recommended
Standard Defrost Thermostat
Close on rise: close 48°F — open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control
CW2XGE CI/CO** 17°F / 7°F
Indoor Unit Only, Pressure Defrost Termination** 48°F
**Use a Temperature Pressure Chart to determine PSIG conversions.
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/
4
Merchandiser Liquid Line (in.)
1
/
2
Merchandiser Suction Line (in.) 1 1/
8
Estimated Charge (lb)*** 4 ft 2.3 8 ft 4.6 12 ft 6.6
***This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound.
Length (in.) added to Lineup by: Each Flat End or Partition 1
1
/2
Each Contoured End 5
3 of 6
P/N 0399331B
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Front of
Case
C
L
18 in. Shelf
16 in. Shelf
12 in. Shelf
25 1/2
(648)
30 1/8 (765)
32 (813)
54
(1372)
5
(127)
7 (178)
3 7/8 (98)
1 3/8 (35)
8 1/2 (216)
68 7/8 (1749)
81 1/2 (2070)
12 5/8
(321)
26
(660)
6 3/8 (162)
FAN
FAN
COIL COIL
5 (127)
21
(533)
9 (229)
Dimensions shown as inches and (mm).
Convertible Island, 3 Display Levels
NSF Certification
These merchandisers are manufactured to meet ANSI /National Sanitation Foundation (NSF ®) Standard #7 requirements.
Impact CW2-XGE
Convertible Island
Electrical Data
Number of Fans 4 ft 8 ft 12 ft
Refrigeration – 6W 2 4 6
Amperes Watts
Merchandiser 4 ft 8 ft 12 ft 4 ft 8 ft 12 ft
Fans (Refrigeration)
Standard (120V 60Hz) 1.00 2.00 3.00 78 156 234
Energy Efficient (120V 60Hz) 0.52 1.04 1.56 36 72 108
Cycling Anti-sweat Heaters NA NA NA NA NA NA
Minimum Circuit Ampacity
With Standard Fans (120V 60Hz) 1.20 2.20 3.20
With Energy Efficient Fans (120V 60Hz) 0.74 1.24 1.76
Maximum Over Current Protection 120V 20 20 20
Electric Defrost Heaters (208V 1ΦΦ) NA NA NA NA NA NA
Standard Lighting 4 ft 8 ft 12 ft 4 ft 8 ft 12 ft
1 Row Canopy 0.51 1.02 1.54 59 118 177
Optional Lighting
2 Rows Canopy 1.02 2.04 3.08 118 236 354
Optional Shelf Lighting
1 Row of Shelves 0.51 1.02 1.54 59 118 177
2 Rows of Shelves 1.02 2.04 3.06 118 236 354
3 Rows of Shelves 2.04 3.06 4.62 177 354 531
4 of 6 CW2XGE Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Impact C2W-XGE
Convertible Island
5 of 6P/N 0399331B
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Fans
120V POWER
Front
BROWN BAND
4 ft case has 2 Fans 8 ft case has 4 Fans 12 ft case has 6 Fans
1
Fans
Fan Wiring
Offtime Defrost
120V NEUTRAL
BROWN BAND
120V POWER
Rear
BROWN BAND
Fans
1
Defrost Termination Thermostat
Optional Shelf Harness and Light Circuits for One Row of Shelves
Shelf Harness
Connector
W
B
120 V
Power
Connector
G
B
W
4
BL
R
BL
BL
W
G
G
G
R
BL
Connector
BROWN BAND
B
G
BL
R
3
Dark Blue
Dark Blue
Refrigeration Thermostat
4
Lt Blue
(Field Installed)
Lt Blue
To Condensing
}
Unit
Shelf Lighting
Connector
G
BL
R
Connector
R
BL G
R
BL
Connector
G
Shelf Light Circuits
BL
Connector
G
R
5
Connector
G G
BL
R
5
BL
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
Grayed components in 12 foot models only.
R = Red Y = Yellow G = Green BL = Blue B = Black W = White
= 120V P
OWER = 120V NEUTRAL = Field GROUND
= Case GROUND
Connector
R
5
6 of 6 CW2XGE Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Light Circuits
Standard Lighting 1 Row Canopy or Optional 1 Row Rail
120V NEUTRAL
ORANGE OR TAN BAND
120V POWER
ORANGE OR TAN BAND
Light
Switch
W
B
4
Optional Lighting 2 Rows Canopy
120V NEUTRAL
ORANGE OR TAN BAND
120V POWER
ORANGE OR TAN BAND
Light
Switch
W
B
B
4
W
4
BL
R
BL
55
BL
R
BL
5
BL
R
BL
BL
R
BL
R
5
BL
R
55
R
5
R
5
R
5
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
Grayed components in 12 foot models only.
R = Red Y = Yellow G = Green BL = Blue B = Black W = White
= 120V POWER = 120V NEUTRAL
Loading...